Literature DB >> 6518060

Noninvasive measurement of cardiac output in healthy preterm and term newborn infants.

D C Alverson, M W Eldridge, J D Johnson, M Aldrich, P Angelus, W Berman.   

Abstract

Although values for cardiac output in the newborn infant have been reported previously, the methods utilized have been invasive. To assess if cardiac output could be determined noninvasively in the neonate, we measured mean ascending aortic blood flow velocity (VAo) in well newborns using a portable 5MHz, range gated, pulsed Doppler velocity meter. Measurements were made from a suprasternal approach in 8 preterm (mean birth weight 1718 gm; mean estimated gestation age 33.3 weeks) and 14 term (mean birthweight 3127 gm; mean EGA 39.8 weeks) healthy infants under one week of age. The internal ascending aortic systolic diameter was determined echographically and aortic cross sectional area was calculated: AAo = pi d2/4. Ascending aortic blood flow (QAo) was then computed as QAo (ml/min) = VAo (cm/sec) X AAo (cm2) X 60 (sec/min). With the exclusion of patent ductus arteriosus (PDA) and detectable intracardiac defects, QAo was taken to equal cardiac output. Flow determinations were normalized to body weight. The 8 preterm infants had a mean cardiac output of 221 +/- 56 (+/- SD) ml/min/kg. The 14 term infants had a similar mean cardiac output of 236 +/- 47 ml/min/kg. The mean cardiac output of all 22 infants was 230 +/- 50. This study establishes normal values for cardiac output determined noninvasively by the Doppler technique, in the first week of life in healthy infants. These values are similar to previously reported systemic blood flows, which were determined by cardiac catheterization and thermodilution methods in healthy newborn infants.

Entities:  

Mesh:

Year:  1984        PMID: 6518060     DOI: 10.1055/s-2007-999991

Source DB:  PubMed          Journal:  Am J Perinatol        ISSN: 0735-1631            Impact factor:   1.862


  19 in total

1.  Superior vena cava flow in newborn infants: a novel marker of systemic blood flow.

Authors:  M Kluckow; N Evans
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-05       Impact factor: 5.747

2.  Cardiac output by Doppler echocardiography in the premature baboon: comparison with radiolabeled microspheres.

Authors:  J P Kinsella; W R Morrow; D R Gerstmann; A F Taylor; R A deLemos
Journal:  Pediatr Cardiol       Date:  1991-04       Impact factor: 1.655

3.  Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.

Authors:  I Hudson; A Houston; T Aitchison; B Holland; T Turner
Journal:  Arch Dis Child       Date:  1990-01       Impact factor: 3.791

4.  Cardiac output by pulsed Doppler in neonates using the apical window.

Authors:  V H Mandelbaum-Isken; O Linderkamp
Journal:  Pediatr Cardiol       Date:  1991-01       Impact factor: 1.655

5.  Early determinants of right and left ventricular output in ventilated preterm infants.

Authors:  N Evans; M Kluckow
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-03       Impact factor: 5.747

6.  Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus.

Authors:  H Hirsimäki; P Kero; O Wanne; R Erkkola; Z Makoi
Journal:  Pediatr Cardiol       Date:  1988       Impact factor: 1.655

Review 7.  Changes of the cardiovascular system during the perinatal period.

Authors:  H Stopfkuchen
Journal:  Eur J Pediatr       Date:  1987-11       Impact factor: 3.183

8.  A Preterm Physiologically Based Pharmacokinetic Model. Part I: Physiological Parameters and Model Building.

Authors:  Khaled Abduljalil; Xian Pan; Amita Pansari; Masoud Jamei; Trevor N Johnson
Journal:  Clin Pharmacokinet       Date:  2020-04       Impact factor: 6.447

9.  Haemodynamic effects of altering arterial oxygen saturation in preterm infants with respiratory failure.

Authors:  J R Skinner; S Hunter; C F Poets; D W Milligan; D Southall; E N Hey
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-03       Impact factor: 5.747

10.  Echocardiographic assessment of cardiac function in shocked very low birthweight infants.

Authors:  A B Gill; A M Weindling
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

View more