Literature DB >> 2407184

Enumeration of total coliforms and Escherichia coli from source water by the defined substrate technology.

S C Edberg1, M J Allen, D B Smith, N J Kriz.   

Abstract

Many water utilities are required to monitor source water for the presence of total coliforms, fecal coliforms, or both. The Colilert system, an application of the defined substrate technology, simultaneously detects the presence of both total coliforms and Escherichia coli directly from a water sample. After incubation, the formula becomes yellow if total coliforms are present and fluorescent at 366 nm if E. coli is in the same sample. No confirmatory tests are required. The Colilert system was previously assessed with distribution water in a national evaluation in both most-probably-number and presence-absence formats and found to produce data equivalent to those obtained by using Standard Methods for the Examination of Water and Wastewater (Standard Methods). The Colilert system was now compared with Standard Methods multiple-tube fermentation (MTF) for the enumeration of total coliforms and E. coli from surface water. All MTF tubes were confirmed according to Standard Methods, and subcultures were made to identify isolates to the species level. The Colilert system was found equally sensitive to MTF testing by regression, t test, chi-square, and likelihood fraction analyses. Specificity of the Colilert system was shown by the isolation of a species of total coliform or E. coli after the appropriate color change. The Colilert test can be used for source water samples when enumeration is required, and the benefits previously described for distribution water testing--sensitivity, specificity, less labor, lower cost, faster results, no noncoliform heterotroph interference--are applicable to this type of water analysis.

Entities:  

Mesh:

Year:  1990        PMID: 2407184      PMCID: PMC183346          DOI: 10.1128/aem.56.2.366-369.1990

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  8 in total

1.  Evaluation of the Autoanalysis Colilert test for detection and enumeration of total coliforms.

Authors:  T C Covert; L C Shadix; E W Rice; J R Haines; R W Freyberg
Journal:  Appl Environ Microbiol       Date:  1989-10       Impact factor: 4.792

2.  Comparison of membrane filter, multiple-fermentation-tube, and presence-absence techniques for detecting total coliforms in small community water systems.

Authors:  N J Jacobs; W L Zeigler; F C Reed; T A Stukel; E W Rice
Journal:  Appl Environ Microbiol       Date:  1986-05       Impact factor: 4.792

3.  Comparison of Clark's presence-absence test and the membrane filter method for coliform detection in potable water samples.

Authors:  W O Pipes; H A Minnigh; B Moyer; M A Troy
Journal:  Appl Environ Microbiol       Date:  1986-09       Impact factor: 4.792

Review 4.  Biochemical identification of new species and biogroups of Enterobacteriaceae isolated from clinical specimens.

Authors:  J J Farmer; B R Davis; F W Hickman-Brenner; A McWhorter; G P Huntley-Carter; M A Asbury; C Riddle; H G Wathen-Grady; C Elias; G R Fanning
Journal:  J Clin Microbiol       Date:  1985-01       Impact factor: 5.948

5.  Frequency distribution of coliforms in water distribution systems.

Authors:  R R Christian; W O Pipes
Journal:  Appl Environ Microbiol       Date:  1983-02       Impact factor: 4.792

6.  Failure of the most-probable-number technique to detect coliforms in drinking water and raw water supplies.

Authors:  T M Evans; C E Waarvick; R J Seidler; M W LeChevallier
Journal:  Appl Environ Microbiol       Date:  1981-01       Impact factor: 4.792

7.  National field evaluation of a defined substrate method for the simultaneous enumeration of total coliforms and Escherichia coli from drinking water: comparison with the standard multiple tube fermentation method.

Authors:  S C Edberg; M J Allen; D B Smith
Journal:  Appl Environ Microbiol       Date:  1988-06       Impact factor: 4.792

8.  National field evaluation of a defined substrate method for the simultaneous detection of total coliforms and Escherichia coli from drinking water: comparison with presence-absence techniques.

Authors:  S C Edberg; M J Allen; D B Smith
Journal:  Appl Environ Microbiol       Date:  1989-04       Impact factor: 4.792

  8 in total
  25 in total

1.  Comparison of beach bacterial water quality indicator measurement methods.

Authors:  Rachel T Noble; Stephen B Weisberg; Molly K Leecaster; Charles D McGee; Kerry Ritter; Kathy O Walker; Patricia M Vainik
Journal:  Environ Monit Assess       Date:  2003 Jan-Feb       Impact factor: 2.513

2.  Comparison and verification of bacterial water quality indicator measurement methods using ambient coastal water samples.

Authors:  John F Griffith; Larissa A Aumand; Ioannice M Lee; Charles D McGee; Laila L Othman; Kerry J Ritter; Kathy O Walker; Stephen B Weisberg
Journal:  Environ Monit Assess       Date:  2006-05       Impact factor: 2.513

3.  Detection and identification of groundwater bacteria capable of escaping entrapment on 0.45-micron-pore-size membrane filters.

Authors:  J J Shirey; G K Bissonnette
Journal:  Appl Environ Microbiol       Date:  1991-08       Impact factor: 4.792

Review 4.  Fluorogenic and chromogenic substrates used in bacterial diagnostics.

Authors:  M Manafi; W Kneifel; S Bascomb
Journal:  Microbiol Rev       Date:  1991-09

5.  Total coliform detection in drinking water: comparison of membrane filtration with Colilert and Coliquik.

Authors:  B H Olson; D L Clark; B B Milner; M H Stewart; R L Wolfe
Journal:  Appl Environ Microbiol       Date:  1991-05       Impact factor: 4.792

6.  Pollution characteristics of antibiotics and antibiotic resistance of coliform bacteria in the Yitong River, China.

Authors:  Yangyang Yu; Guanlan Wu; Chengzhi Wang; Nan Lu; Xing Yuan; Xiaolin Zhu
Journal:  Environ Monit Assess       Date:  2019-07-27       Impact factor: 2.513

7.  Comparative study of fluorogenic and chromogenic media for specific detection of environmental isolates of thermotolerant Escherichia coli.

Authors:  Pramod W Ramteke; Suman Tewari
Journal:  Environ Monit Assess       Date:  2002-10       Impact factor: 2.513

8.  Distribution and Characterization of Salmonella enterica Isolates from Irrigation Ponds in the Southeastern United States.

Authors:  Zhiyao Luo; Ganyu Gu; Amber Ginn; Mihai C Giurcanu; Paige Adams; George Vellidis; Ariena H C van Bruggen; Michelle D Danyluk; Anita C Wright
Journal:  Appl Environ Microbiol       Date:  2015-04-24       Impact factor: 4.792

9.  Spectrofluorometric assay for rapid detection of total and fecal coliforms from surface water.

Authors:  S J Park; E J Lee; D H Lee; S H Lee; S J Kim
Journal:  Appl Environ Microbiol       Date:  1995-05       Impact factor: 4.792

10.  Point-of-use water disinfection using UV light-emitting diodes to reduce bacterial contamination.

Authors:  Kristina Y Nelson; Dena W McMartin; Christopher K Yost; Ken J Runtz; Takaya Ono
Journal:  Environ Sci Pollut Res Int       Date:  2013-02-20       Impact factor: 4.223

View more