The effect of drilling speed on early bone healing to oral implants.

Sinem Yeniyol1, Ryo Jimbo, Charles Marin, Nick Tovar, Malvin N Janal, Paulo G Coelho.   

Abstract

OBJECTIVE: This study evaluated the effect of drilling speed on early bone healing in dog tibiae. STUDY
DESIGN: Thirty-six implants (4.0-mm diameter × 10-mm length) were placed in the proximal tibiae of 6 beagles with drilling speeds of 100, 500, and 1000 rpm, and insertion torque was recorded. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated.
RESULTS: Significant increase from 1 to 3 weeks was observed for all groups for BIC, whereas no significant differences between 1 and 3 weeks were detected for the 100- and 500-rpm groups for BAFO (P > .34 and P > .46, respectively). A significant difference from 1 to 3 weeks was observed for the 1000-rpm group (P < .03). The 100- and 500-rpm groups presented significantly higher BAFO than the 1000-rpm group at 1 week (P = .002).
CONCLUSIONS: Drilling speed is one of the decisive factors for early osseointegration, and overall, drilling at 1000 rpm seemed to yield the strongest biologic responses.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24055149     DOI: 10.1016/j.oooo.2013.07.001

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol


  8 in total

1.  Bone Micromorphology and Material Attrition After Sonic, Ultrasonic and Conventional Osteotomies.

Authors:  Ashkan Rashad; Stefan Schwan; Alireza Nasirpour; Inge Schmitz; Henning Hanken; Reinhard E Friedrich; Martin Gosau
Journal:  In Vivo       Date:  2021 May-Jun       Impact factor: 2.155

2.  Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.

Authors:  R A Delgado-Ruiz; E Velasco Ortega; G E Romanos; S Gerhke; I Newen; J L Calvo-Guirado
Journal:  Clin Oral Investig       Date:  2017-04-22       Impact factor: 3.573

3.  Biophysical regulation of osteotomy healing: An animal study.

Authors:  Liao Wang; Maziar Aghvami; John Brunski; Jill Helms
Journal:  Clin Implant Dent Relat Res       Date:  2017-06-13       Impact factor: 3.932

4.  Osseodensification for enhancement of spinal surgical hardware fixation.

Authors:  Christopher D Lopez; Adham M Alifarag; Andrea Torroni; Nick Tovar; J Rodrigo Diaz-Siso; Lukasz Witek; Eduardo D Rodriguez; Paulo G Coelho
Journal:  J Mech Behav Biomed Mater       Date:  2017-01-13

5.  An Osteotomy Tool That Preserves Bone Viability: Evaluation in Preclinical and Clinical Settings.

Authors:  Oded Bahat; Xing Yin; Stefan Holst; Ion Zabalegui; Eva Berroeta; Javier Pérez; Peter Wöhrle; Norbert Sörgel; John Brunski; Jill A Helms
Journal:  J Clin Med       Date:  2022-04-30       Impact factor: 4.964

6.  Healing at sites prepared using different drilling protocols. An experimental study in the tibiae of sheep.

Authors:  Vittorio Favero; Shigeru Sakuma; Karol Alí Apaza Alccayhuaman; Guillermo Alejandro Benedetto; Franco Bengazi; Daniele Botticelli
Journal:  PLoS One       Date:  2018-08-29       Impact factor: 3.240

7.  A Novel Osteotomy Preparation Technique to Preserve Implant Site Viability and Enhance Osteogenesis.

Authors:  Chih-Hao Chen; Benjamin R Coyac; Masaki Arioka; Brian Leahy; U Serdar Tulu; Maziar Aghvami; Stefan Holst; Waldemar Hoffmann; Antony Quarry; Oded Bahat; Benjamin Salmon; John B Brunski; Jill A Helms
Journal:  J Clin Med       Date:  2019-02-01       Impact factor: 4.241

8.  Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Steel vs. Zirconia Implant Drill.

Authors:  Antonio Scarano; Felice Lorusso; Sammy Noumbissi
Journal:  J Clin Med       Date:  2020-01-05       Impact factor: 4.241