Literature DB >> 24049684

Spectrally encoded confocal microscopy of esophageal tissues at 100 kHz line rate.

Simon C Schlachter1, Dongkyun Kang, Michalina J Gora, Paulino Vacas-Jacques, Tao Wu, Robert W Carruth, Eric J Wilsterman, Brett E Bouma, Kevin Woods, Guillermo J Tearney.   

Abstract

Spectrally encoded confocal microscopy (SECM) is a reflectance confocal microscopy technology that uses a diffraction grating to illuminate different locations on the sample with distinct wavelengths. SECM can obtain line images without any beam scanning devices, which opens up the possibility of high-speed imaging with relatively simple probe optics. This feature makes SECM a promising technology for rapid endoscopic imaging of internal organs, such as the esophagus, at microscopic resolution. SECM imaging of the esophagus has been previously demonstrated at relatively low line rates (5 kHz). In this paper, we demonstrate SECM imaging of large regions of esophageal tissues at a high line imaging rate of 100 kHz. The SECM system comprises a wavelength-swept source with a fast sweep rate (100 kHz), high output power (80 mW), and a detector unit with a large bandwidth (100 MHz). The sensitivity of the 100-kHz SECM system was measured to be 60 dB and the transverse resolution was 1.6 µm. Excised swine and human esophageal tissues were imaged with the 100-kHz SECM system at a rate of 6.6 mm(2)/sec. Architectural and cellular features of esophageal tissues could be clearly visualized in the SECM images, including papillae, glands, and nuclei. These results demonstrate that large-area SECM imaging of esophageal tissues can be successfully conducted at a high line imaging rate of 100 kHz, which will enable whole-organ SECM imaging in vivo.

Entities:  

Keywords:  (170.1790) Confocal microscopy; (170.2680) Gastrointestinal; (170.4730) Optical pathology

Year:  2013        PMID: 24049684      PMCID: PMC3771834          DOI: 10.1364/BOE.4.001636

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  18 in total

1.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second.

Authors:  Wolfgang Wieser; Benjamin R Biedermann; Thomas Klein; Christoph M Eigenwillig; Robert Huber
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

2.  In vivo histology of Barrett's esophagus and associated neoplasia by confocal laser endomicroscopy.

Authors:  Ralf Kiesslich; Liebwin Gossner; Martin Goetz; Alexandra Dahlmann; Michael Vieth; Manfred Stolte; Arthur Hoffman; Michael Jung; Bernhard Nafe; Peter R Galle; Markus F Neurath
Journal:  Clin Gastroenterol Hepatol       Date:  2006-07-13       Impact factor: 11.382

3.  Spectrally encoded confocal microscopy.

Authors:  G J Tearney; R H Webb; B E Bouma
Journal:  Opt Lett       Date:  1998-08-01       Impact factor: 3.776

4.  Optimal detection pinhole for lowering speckle noise while maintaining adequate optical sectioning in confocal reflectance microscopes.

Authors:  Christopher Glazowski; Milind Rajadhyaksha
Journal:  J Biomed Opt       Date:  2012-08       Impact factor: 3.170

5.  High-speed interferometric spectrally encoded flow cytometry.

Authors:  Lior Golan; Daniella Yeheskely-Hayon; Limor Minai; Dvir Yelin
Journal:  Opt Lett       Date:  2012-12-15       Impact factor: 3.776

6.  Optical time-stretch confocal microscopy at 1 μm.

Authors:  Terence T W Wong; Andy K S Lau; Kenneth K Y Wong; Kevin K Tsia
Journal:  Opt Lett       Date:  2012-08-15       Impact factor: 3.776

7.  Reflectance confocal microscopy for the diagnosis of eosinophilic esophagitis: a pilot study conducted on biopsy specimens.

Authors:  Hongki Yoo; DongKyun Kang; Aubrey J Katz; Gregory Y Lauwers; Norman S Nishioka; Yukako Yagi; Pornthep Tanpowpong; Jacqueline Namati; Brett E Bouma; Guillermo J Tearney
Journal:  Gastrointest Endosc       Date:  2011-09-23       Impact factor: 9.427

8.  >400 kHz repetition rate wavelength-swept laser and application to high-speed optical frequency domain imaging.

Authors:  Wang-Yuhl Oh; Benjamin J Vakoc; Milen Shishkov; Guillermo J Tearney; Brett E Bouma
Journal:  Opt Lett       Date:  2010-09-01       Impact factor: 3.776

9.  Spectrally encoded confocal scanning laser ophthalmoscopy.

Authors:  Yuankai K Tao; Joseph A Izatt
Journal:  Opt Lett       Date:  2010-02-15       Impact factor: 3.776

10.  High-resolution miniprobe-based confocal microscopy in combination with video mosaicing (with video).

Authors:  Valentin Becker; Tom Vercauteren; Claus Hann von Weyhern; Christian Prinz; Roland M Schmid; Alexander Meining
Journal:  Gastrointest Endosc       Date:  2007-09-04       Impact factor: 9.427

View more
  11 in total

1.  Endoscopic probe optics for spectrally encoded confocal microscopy.

Authors:  Dongkyun Kang; Robert W Carruth; Minkyu Kim; Simon C Schlachter; Milen Shishkov; Kevin Woods; Nima Tabatabaei; Tao Wu; Guillermo J Tearney
Journal:  Biomed Opt Express       Date:  2013-09-03       Impact factor: 3.732

2.  All-fiber wavelength swept ring laser based on Fabry-Perot filter for optical frequency domain imaging.

Authors:  Changsu Jun; Martin Villiger; Wang-Yuhl Oh; Brett E Bouma
Journal:  Opt Express       Date:  2014-10-20       Impact factor: 3.894

3.  Spectrally encoded coherence tomography and reflectometry: Simultaneous en face and cross-sectional imaging at 2 gigapixels per second.

Authors:  Mohamed T El-Haddad; Ivan Bozic; Yuankai K Tao
Journal:  J Biophotonics       Date:  2017-12-27       Impact factor: 3.207

4.  Tri-modal microscope for head and neck tissue identification.

Authors:  Etienne De Montigny; Nadir Goulamhoussen; Wendy-Julie Madore; Mathias Strupler; Olguta Ecaterina Gologan; Tareck Ayad; Caroline Boudoux
Journal:  Biomed Opt Express       Date:  2016-02-02       Impact factor: 3.732

Review 5.  High-speed laser-scanning biological microscopy using FACED.

Authors:  Queenie T K Lai; Gwinky G K Yip; Jianglai Wu; Justin S J Wong; Michelle C K Lo; Kelvin C M Lee; Tony T H D Le; Hayden K H So; Na Ji; Kevin K Tsia
Journal:  Nat Protoc       Date:  2021-08-02       Impact factor: 13.491

6.  Tethered confocal endomicroscopy capsule for diagnosis and monitoring of eosinophilic esophagitis.

Authors:  Nima Tabatabaei; Dongkyun Kang; Tao Wu; Minkyu Kim; Robert W Carruth; John Leung; Jenny S Sauk; Wayne Shreffler; Qian Yuan; Aubrey Katz; Norman S Nishioka; Guillermo J Tearney
Journal:  Biomed Opt Express       Date:  2013-12-13       Impact factor: 3.732

7.  High-speed label-free confocal microscopy of Caenorhabditis elegans with near infrared spectrally encoded confocal microscopy.

Authors:  Sadaf Rashtchian; Khaled Youssef; Pouya Rezai; Nima Tabatabaei
Journal:  Biomed Opt Express       Date:  2021-05-25       Impact factor: 3.732

8.  Spectrally encoded confocal microscopy for diagnosing breast cancer in excision and margin specimens.

Authors:  Elena F Brachtel; Nicole B Johnson; Amelia E Huck; Travis L Rice-Stitt; Mark G Vangel; Barbara L Smith; Guillermo J Tearney; Dongkyun Kang
Journal:  Lab Invest       Date:  2016-01-18       Impact factor: 5.662

9.  Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis.

Authors:  Nima Tabatabaei; DongKyun Kang; Minkyu Kim; Tao Wu; Catriona N Grant; Mireille Rosenberg; Norman S Nishioka; Paul E Hesterberg; John Garber; Qian Yuan; Aubrey J Katz; Guillermo J Tearney
Journal:  Sci Rep       Date:  2018-02-08       Impact factor: 4.379

10.  New Endoscopic Imaging Technology Based on MEMS Sensors and Actuators.

Authors:  Zhen Qiu; Wibool Piyawattanamatha
Journal:  Micromachines (Basel)       Date:  2017-07-02       Impact factor: 2.891

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.