Literature DB >> 18833773

Effects of light curing modes and resin composites on temperature rise under human dentin: an in vitro study.

Ihsan Hubbezoglu1, Arife Dogan, Orhan Murat Dogan, Giray Bolayir, Bulent Bek.   

Abstract

The influence of three curing modes of a high-powered LED curing unit on temperature rise under 2-mm-thick dentin was investigated during the polymerization of resin composite samples of Admira, Filtek P60, Premise, Tetric Flow, Tetric Ceram, and Filtek Z250. Ninety standard specimens were prepared. The bonding agents and resin composites were cured with standard, pulse, or soft-start mode (n=5 for each curing mode). Temperature rise was measured using a type L thermocouple. Data were analyzed by two-way ANOVA and Tukey's test. Soft-start curing led to statistically higher temperature rises compared than the other two modes. The highest temperature rise was observed for Admira and Tetric Flow cured with soft-start mode. The lowest temperature rise was observed for Premise cured with pulse mode. However, temperature rise did not reach the critical value that can cause pulpal damage by virtue of a prominent safety feature of the high-powered LED LCU, which ensures that no excessive heat is produced by all the three curing modes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18833773     DOI: 10.4012/dmj.27.581

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  3 in total

1.  Physical properties of self-, dual-, and light-cured direct core materials.

Authors:  Stefan Rüttermann; Ian Alberts; Wolfgang H M Raab; Ralf R Janda
Journal:  Clin Oral Investig       Date:  2010-04-07       Impact factor: 3.573

2.  Thermal analysis of bulk filled composite resin polymerization using various light curing modes according to the curing depth and approximation to the cavity wall.

Authors:  Hoon-Sang Chang; Kyu-Jeong Cho; Su-Jung Park; Bin-Na Lee; Yun-Chan Hwang; Won-Mann Oh; In-Nam Hwang
Journal:  J Appl Oral Sci       Date:  2013 Jul-Aug       Impact factor: 2.698

3.  Assessment of Heat Hazard during the Polymerization of Selected Light-Sensitive Dental Materials.

Authors:  Maciej Janeczek; Katarzyna Herman; Katarzyna Fita; Krzysztof Dudek; Małgorzata Kowalczyk-Zając; Agnieszka Czajczyńska-Waszkiewicz; Dagmara Piesiak-Pańczyszyn; Piotr Kosior; Maciej Dobrzyński
Journal:  Biomed Res Int       Date:  2016-10-20       Impact factor: 3.411