| Literature DB >> 26557716 |
Ryan Jin-Young Kim1, In-Bog Lee1, Jin-Young Yoo2, Su-Jung Park2, Sin-Young Kim3, Young-Ah Yi4, Ji-Yun Hwang5, Deog-Gyu Seo1.
Abstract
OBJECTIVE: The aim of this study was to evaluate the temperature change at various sites within the composite and on the pulpal side of dentin during polymerization of two composite increments.Entities:
Mesh:
Substances:
Year: 2015 PMID: 26557716 PMCID: PMC4628699 DOI: 10.1155/2015/923808
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Figure 1Schematic diagram of specimen setup showing the position of thermocouples and dimension of tooth cavity (BC: bottom center of the cavity; MC: top center of 1st increment; TC: top center of 2nd increment; BE: bottom corner of 1st increment; ME: top corner of 1st increment; TE: top corner of 2nd increment; PD: bottom center on pulpal aspect of dentin; and CL: center of curing light guide tip).
Figure 2Mean temperatures measured during polymerization of (a) 1st composite increment and (b) 2nd composite increment (BC: bottom center of the cavity; MC: top center of 1st increment; TC: top center of 2nd increment; BE: bottom corner of 1st increment; ME: top corner of 1st increment; TE: top corner of 2nd increment; PD: bottom center on pulpal aspect of dentin; and CL: center of curing light guide tip).
Mean maximum temperatures (°C) at assigned measurement sites during polymerization of each increment.
| Measurement sites | ||||||||
|---|---|---|---|---|---|---|---|---|
| BC | MC | TC | BE | ME | TE | PD | CL | |
| 1st increment | 52.8 (2.5)b | 59.8 (3.8)a | N/A | 48.4 (4.0)b | 51.3 (5.9)b | N/A | 39.8 (1.6)c | 50.7 (1.4)b |
| 2nd increment | 46.7 (1.1)df | 51.7 (1.5)bc | 58.5 (2.1)a | 44.5 (1.4)ef | 48.0 (2.1)cde | 52.6 (4.0)b | 38.8 (0.1)g | 50.0 (1.3)bd |
Standard deviations are in parentheses.
Values with identical superscript letters are similar within the same increment (Tukey's HSD, P > 0.05).
N/A: Not applicable.
BC: bottom center of the cavity; MC: top center of 1st increment; TC: top center of 2nd increment; BE: bottom corner of 1st increment; ME: top corner of 1st increment; TE: top corner of 2nd increment; PD: bottom center on pulpal aspect of dentin; and CL: center of curing light guide tip.
Figure 3Means and standard deviations of maximum temperature during polymerization of 1st and 2nd composite increments. Asterisk indicates statistical difference between the 1st and 2nd composite increments (BC: bottom center of the cavity; MC: top center of 1st increment; TC: top center of 2nd increment; BE: bottom corner of 1st increment; ME: top corner of 1st increment; TE: top corner of 2nd increment; PD: bottom center on pulpal aspect of dentin; and CL: center of curing light guide tip).