Literature DB >> 24007145

4D tumor centroid tracking using orthogonal 2D dynamic MRI: implications for radiotherapy planning.

Erik Tryggestad1, Aaron Flammang, Russell Hales, Joseph Herman, Junghoon Lee, Todd McNutt, Teboh Roland, Steven M Shea, John Wong.   

Abstract

PURPOSE: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited "snapshot" in time. Heretofore, long-duration, 4D motion characterization for radiotherapy planning, margin optimization, and validation have been impractical for safety reasons, requiring invasive markers imaged under x-ray fluoroscopy. To characterize 3D tumor motion and associated variability over durations more consistent with treatments, the authors have developed a practical dynamic MRI (dMRI) technique employing two orthogonal planes acquired in a continuous, interleaved fashion.
METHODS: 2D balanced steady-state free precession MRI was acquired continuously over 9-14 min at approximately 4 Hz in three healthy volunteers using a commercial 1.5 T system; alternating orthogonal imaging planes (sagittal, coronal, sagittal, etc.) were employed. The 2D in-plane pixel resolution was 2 × 2 mm(2) with a 5 mm slice profile. Simultaneous with image acquisition, the authors monitored a 1D surrogate respiratory signal using a device available with the MRI system. 2D template matching-based anatomic feature registration, or tracking, was performed independently in each orientation. 4D feature tracking at the raw frame rate was derived using spline interpolation.
RESULTS: Tracking vascular features in the lung for two volunteers and pancreatic features in one volunteer, the authors have successfully demonstrated this method. Registration error, defined here as the difference between the sagittal and coronal tracking result in the SI direction, ranged from 0.7 to 1.6 mm (1σ) which was less than the acquired image resolution. Although the healthy volunteers were instructed to relax and breathe normally, significantly variable respiration was observed. To demonstrate potential applications of this technique, the authors subsequently explored the intrafraction stability of hypothetical tumoral internal target volumes and 3D spatial probability distribution functions. The surrogate respiratory information allowed the authors to show how this technique can be used to study correlations between internal and external (surrogate) information over these prolonged durations. However, compared against the gold standard of the time stamps in the dMRI frames, the temporal synchronization of the surrogate 1D respiratory information was shown to be likely unreliable.
CONCLUSIONS: The authors have established viability of a novel and practical pretreatment, 4D tumor centroid tracking method employing a commercially available dynamic MRI sequence. Further developments from the vendor are likely needed to provide a reliably synchronized surrogate 1D respiratory signal, which will likely broaden the utility of this method in the pretreatment radiotherapy planning context.

Entities:  

Mesh:

Year:  2013        PMID: 24007145     DOI: 10.1118/1.4818656

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  High-quality t2-weighted 4-dimensional magnetic resonance imaging for radiation therapy applications.

Authors:  Dongsu Du; Shelton D Caruthers; Carri Glide-Hurst; Daniel A Low; H Harold Li; Sasa Mutic; Yanle Hu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-30       Impact factor: 7.038

2.  A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site.

Authors:  Chiara Paganelli; Paul Summers; Chiara Gianoli; Massimo Bellomi; Guido Baroni; Marco Riboldi
Journal:  Med Biol Eng Comput       Date:  2017-04-08       Impact factor: 2.602

3.  A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities.

Authors:  Amy Yuan; Jie Wei; Carl P Gaebler; Hailiang Huang; Devin Olek; Guang Li
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-09-03       Impact factor: 7.038

4.  Four-dimensional magnetic resonance imaging using axial body area as respiratory surrogate: initial patient results.

Authors:  Juan Yang; Jing Cai; Hongjun Wang; Zheng Chang; Brian G Czito; Mustafa R Bashir; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-01-17       Impact factor: 7.038

5.  Evaluation of lung tumor motion management in radiation therapy with dynamic MRI.

Authors:  Seyoun Park; Rana Farah; Steven M Shea; Erik Tryggestad; Russell Hales; Junghoon Lee
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-03

6.  Direct Comparison of Respiration-Correlated Four-Dimensional Magnetic Resonance Imaging Reconstructed Using Concurrent Internal Navigator and External Bellows.

Authors:  Guang Li; Jie Wei; Devin Olek; Mo Kadbi; Neelam Tyagi; Kristen Zakian; James Mechalakos; Joseph O Deasy; Margie Hunt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-11-09       Impact factor: 7.038

7.  Evaluation of template matching for tumor motion management with cine-MR images in lung cancer patients.

Authors:  Xiutao Shi; Tejan Diwanji; Karen E Mooney; Jolinta Lin; Steven Feigenberg; Warren D D'Souza; Nilesh N Mistry
Journal:  Med Phys       Date:  2014-05       Impact factor: 4.071

8.  Novel Super-Resolution Approach to Time-Resolved Volumetric 4-Dimensional Magnetic Resonance Imaging With High Spatiotemporal Resolution for Multi-Breathing Cycle Motion Assessment.

Authors:  Guang Li; Jie Wei; Mo Kadbi; Jason Moody; August Sun; Shirong Zhang; Svetlana Markova; Kristen Zakian; Margie Hunt; Joseph O Deasy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-02-17       Impact factor: 7.038

9.  A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging.

Authors:  Wendy Harris; Lei Ren; Jing Cai; You Zhang; Zheng Chang; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-02-06       Impact factor: 7.038

10.  T2-weighted four dimensional magnetic resonance imaging with result-driven phase sorting.

Authors:  Yilin Liu; Fang-Fang Yin; Brian G Czito; Mustafa R Bashir; Jing Cai
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

View more