Literature DB >> 2702377

A new high-definition microfocal X-ray unit.

J C Buckland-Wright1.   

Abstract

A new microfocal unit is described with an operating range up to 170 kVp (limited to 125 kVp for medical use), 0-1 mA and a maximum output of 75-80 W. The unit comprises a lanthanum hexaboride (LaB6) cathode, a single electromagnetic lens and a stationary oil-cooled multifaced tungsten target. The estimated source size ranges from 6 to 20 microns between 14 and 77 W. The tube's output is x 3 to x 3.5 greater than that of a conventional X-ray unit. The use of fast rare-earth film-screen systems permits exposures of most views of the patient within 1 s. The spatial resolution within these film-screen systems is 40-30 microns diameter at magnifications of x 5-10. The tube is fixed so as to project a horizontal beam and the patient table is designed to position the patient close to the source (20-30 cm) with the film placed at a focus-film distance of 1-3 m. Stereopair macroradiographs permit greater accuracy in the identification and location of radiographic features. The large magnification and resolution of macroradiographs allow direct and accurate measurement of radiographic features.

Entities:  

Mesh:

Year:  1989        PMID: 2702377     DOI: 10.1259/0007-1285-62-735-201

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  12 in total

1.  Techetium 99m methylene diphosphonate bone scanning in osteoarthritic hands.

Authors:  J C Buckland-Wright; D G Macfarlane; I Fogelman; P Emery; J A Lynch
Journal:  Eur J Nucl Med       Date:  1991

2.  Method for automatization of the alignment of a laboratory based x-ray phase contrast edge illumination system.

Authors:  T P Millard; M Endrizzi; K Ignatyev; C K Hagen; P R T Munro; R D Speller; A Olivo
Journal:  Rev Sci Instrum       Date:  2013-08       Impact factor: 1.523

3.  Variation in the apparent density of human mandibular bone with age and dental status.

Authors:  V J Kingsmill; A Boyde
Journal:  J Anat       Date:  1998-02       Impact factor: 2.610

4.  Fractal signature analysis measures cancellous bone organisation in macroradiographs of patients with knee osteoarthritis.

Authors:  J C Buckland-Wright; J A Lynch; D G Macfarlane
Journal:  Ann Rheum Dis       Date:  1996-10       Impact factor: 19.103

5.  Accuracy and precision of joint space width measurements in standard and macroradiographs of osteoarthritic knees.

Authors:  J C Buckland-Wright; D G Macfarlane; S A Williams; R J Ward
Journal:  Ann Rheum Dis       Date:  1995-11       Impact factor: 19.103

Review 6.  Quantitative radiography of osteoarthritis.

Authors:  J C Buckland-Wright
Journal:  Ann Rheum Dis       Date:  1994-04       Impact factor: 19.103

7.  Osteophytes in the osteoarthritic hand: their incidence, size, distribution, and progression.

Authors:  J C Buckland-Wright; D G Macfarlane; J A Lynch
Journal:  Ann Rheum Dis       Date:  1991-09       Impact factor: 19.103

8.  Comparison of clinical, radionuclide, and radiographic features of osteoarthritis of the hands.

Authors:  D G Macfarlane; J C Buckland-Wright; P Emery; I Fogelman; B Clark; J Lynch
Journal:  Ann Rheum Dis       Date:  1991-09       Impact factor: 19.103

9.  Joint space width measures cartilage thickness in osteoarthritis of the knee: high resolution plain film and double contrast macroradiographic investigation.

Authors:  J C Buckland-Wright; D G Macfarlane; J A Lynch; M K Jasani; C R Bradshaw
Journal:  Ann Rheum Dis       Date:  1995-04       Impact factor: 19.103

10.  Fractal signature analysis of macroradiographs measures trabecular organization in lumbar vertebrae of postmenopausal women.

Authors:  J C Buckland-Wright; J A Lynch; J Rymer; I Fogelman
Journal:  Calcif Tissue Int       Date:  1994-02       Impact factor: 4.333

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.