Literature DB >> 11548930

An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

A Olivo1, F Arfelli, G Cantatore, R Longo, R H Menk, S Pani, M Prest, P Poropat, L Rigon, G Tromba, E Vallazza, E Castelli.   

Abstract

Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the medical field. On the other hand, digital radiology is undergoing a wide diffusion, and its benefits are presently very well understood. Up to now, however, the strong pixel size constraints associated with phase contrast pattern detection limited the possibility of exploiting the advantages of phase contrast in digital radiology applications. In this paper, an innovative setup capable of removing the pixel size constraints, and thus opening the way to low dose digital phase contrast imaging, is described. Furthermore, we introduce an imaging technique based on the detection of radiation scattered at small angles: the information extracted from the sample is increased at no dose expense. We believe that several radiological fields, mammography being the first important example, may benefit from the herein described innovative imaging techniques.

Mesh:

Year:  2001        PMID: 11548930     DOI: 10.1118/1.1388219

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  Method for automatization of the alignment of a laboratory based x-ray phase contrast edge illumination system.

Authors:  T P Millard; M Endrizzi; K Ignatyev; C K Hagen; P R T Munro; R D Speller; A Olivo
Journal:  Rev Sci Instrum       Date:  2013-08       Impact factor: 1.523

2.  Phase and absorption retrieval using incoherent X-ray sources.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Proc Natl Acad Sci U S A       Date:  2012-08-13       Impact factor: 11.205

3.  Multi-modal hard x-ray imaging with a laboratory source using selective reflection from a mirror.

Authors:  Daniele Pelliccia; David M Paganin
Journal:  Biomed Opt Express       Date:  2014-03-12       Impact factor: 3.732

4.  Feasibility testing of a pre-clinical coded aperture phase contrast imaging configuration using a simple fast Monte Carlo simulator.

Authors:  Anthony Kavanagh; Alessandro Olivo; Robert Speller; Borivoj Vojnovic
Journal:  Biomed Opt Express       Date:  2013-12-04       Impact factor: 3.732

5.  Medicine, material science and security: the versatility of the coded-aperture approach.

Authors:  P R T Munro; M Endrizzi; P C Diemoz; C K Hagen; M B Szafraniec; T P Millard; C E Zapata; R D Speller; A Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

6.  Sensitivity of edge illumination X-ray phase-contrast imaging.

Authors:  P C Diemoz; M Endrizzi; A Bravin; I K Robinson; A Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

7.  Synchrotron- and laboratory-based X-ray phase-contrast imaging for imaging mouse articular cartilage in the absence of radiopaque contrast agents.

Authors:  Massimo Marenzana; Charlotte K Hagen; Patricia Das Neves Borges; Marco Endrizzi; Magdalena B Szafraniec; Tonia L Vincent; Luigi Rigon; Fulvia Arfelli; Ralf-Hendrik Menk; Alessandro Olivo
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

8.  'Taking X-ray phase contrast imaging into mainstream applications' and its satellite workshop 'Real and reciprocal space X-ray imaging'.

Authors:  Alessandro Olivo; Ian Robinson
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-01-27       Impact factor: 4.226

9.  A quantitative, non-interferometric X-ray phase contrast imaging technique.

Authors:  Peter R T Munro; Luigi Rigon; Konstantin Ignatyev; Frances C M Lopez; Diego Dreossi; Robert D Speller; Alessandro Olivo
Journal:  Opt Express       Date:  2013-01-14       Impact factor: 3.894

10.  Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens.

Authors:  Masami Ando; Naoki Sunaguchi; Yanlin Wu; Synho Do; Yongjin Sung; Abner Louissaint; Tetsuya Yuasa; Shu Ichihara; Rajiv Gupta
Journal:  Eur Radiol       Date:  2013-09-19       Impact factor: 5.315

View more