Literature DB >> 24005377

Biometrical analysis of the shoulder joint regarding glenoid implant dimensions for arthroplasty.

Jörn Kircher1, Bernd Bittersohl, Christoph Zilkens, Achim Hedtmann, Rüdiger Krauspe.   

Abstract

PURPOSE: Reduced bone stock and difficult intraoperative orientation are challenges in glenoid replacement surgery. New implant designs and methods for fixation, such as locking screws, extra-long central pegs and/or central compression screws are targeting these issues. The objective of this study is the analysis of the glenoid dimension regarding maximum central peg diameter and peg length (PL), and maximum screw length (SL) for glenoid fixation.
METHODS: Retrospective analysis of magnetic resonance imaging (n = 50) scans. Measurement of the maximum inferior glenoid diameter (GD), SL, maximum length of a 9.9, 10 and 11.4 mm central peg (PL) in the transverse plane; glenoid version (GV), humeral head diameter (HHD). Two independent measurements.
RESULTS: Mean age: 49.0 ± 15.7 years (17-80) (n = 20 female, 49.6 ± 16.0; n = 30 male, 48.6 ± 15.7). Mean values of measurement were GD: 28.9 ± 3.7 mm (21-39); SL: 34.1 ± 4.9 mm (26-44); PL 9.9 mm: 19.4 ± 4.3 mm (9-30); PL 10 mm: 19.0 ± 4.4 mm (8-30); PL 11.4 mm: 16.5 ± 4.1 mm (7-26) with significant gender differences (p = 0.001; p = 0.022; p = 0.001); GV: -0.6° ± 4.9° (-10 to 11); HHD: 50.0 mm ± 4.9 (41-61). There was good correlation between PL and SL (r = 0.32, p = 0.024) and for GD and PL (r = 0.61, p = 0.001; r = 0.57, p = 0.001; r = 0.96, p = 0.001). The ratio of HHD and GD was very constant with 0.6 ± 0.07.
CONCLUSIONS: These data indicate the high interindividual variability of glenoid morphology including significant gender-related differences. The good correlation between humeral head size and GD and maximum central PL can be helpful for cases with reduced bone stock in decision-making about implant size and bone grafting.

Entities:  

Mesh:

Year:  2013        PMID: 24005377     DOI: 10.1007/s00276-013-1197-y

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  28 in total

1.  Glenoid cancellous bone strength and modulus.

Authors:  C Anglin; P Tolhurst; U P Wyss; D R Pichora
Journal:  J Biomech       Date:  1999-10       Impact factor: 2.712

2.  Normal glenoid rim anatomy and the reliability of shoulder instability measurements based on intrasite correlation.

Authors:  Hans-Christian Jeske; Martina Oberthaler; Michael Klingensmith; Christian Dallapozza; Vinzenz Smekal; Markus Wambacher; Franz Kralinger
Journal:  Surg Radiol Anat       Date:  2009-03-28       Impact factor: 1.246

Review 3.  Principles of glenoid component design and strategies for managing glenoid bone loss in revision shoulder arthroplasty in the absence of infection and rotator cuff tear.

Authors:  Surena Namdari; Danny P Goel; James Romanowski; David Glaser; Jon J P Warner
Journal:  J Shoulder Elbow Surg       Date:  2011-06-25       Impact factor: 3.019

4.  A comparison of subchondral bone mineralization between the glenoid cavity and the humeral head on 57 cadaverous shoulder joints.

Authors:  Marko Kraljević; Valentin Zumstein; Rolf Hügli; Magdalena Müller-Gerbl
Journal:  Surg Radiol Anat       Date:  2012-11-03       Impact factor: 1.246

5.  A 3D-CT scan study of the humeral and glenoid planes in 150 normal shoulders.

Authors:  Lieven De Wilde; Saartje Defoort; Tom R G M Verstraeten; Wendy Speeckaert; Philippe Debeer
Journal:  Surg Radiol Anat       Date:  2011-06-08       Impact factor: 1.246

6.  Glenoid loosening and failure in anatomical total shoulder arthroplasty: is revision with a reverse shoulder arthroplasty a reliable option?

Authors:  Barbara Melis; Nicolas Bonnevialle; Lionel Neyton; Christophe Lévigne; Luc Favard; Gilles Walch; Pascal Boileau
Journal:  J Shoulder Elbow Surg       Date:  2011-11-01       Impact factor: 3.019

7.  Glenoid size, inclination, and version: an anatomic study.

Authors:  R S Churchill; J J Brems; H Kotschi
Journal:  J Shoulder Elbow Surg       Date:  2001 Jul-Aug       Impact factor: 3.019

Review 8.  Hypoplasia of the glenoid. A review of sixteen patients.

Authors:  M A Wirth; F R Lyons; C A Rockwood
Journal:  J Bone Joint Surg Am       Date:  1993-08       Impact factor: 5.284

9.  Gender differences in glenoid anatomy: an anatomic study.

Authors:  Andrea Merrill; Kara Guzman; Suzanne L Miller
Journal:  Surg Radiol Anat       Date:  2008-10-21       Impact factor: 1.246

Review 10.  Indications, complications, and results of shoulder arthroplasty.

Authors:  M A J van de Sande; R Brand; P M Rozing
Journal:  Scand J Rheumatol       Date:  2006 Nov-Dec       Impact factor: 3.641

View more
  2 in total

1.  Age-dependent variation of glenohumeral anatomy: a radiological study.

Authors:  Benjamin Bockmann; Sonja Soschynski; Philipp Lechler; Steffen Ruchholtz; Florian Debus; Tim Schwarting; Michael Frink
Journal:  Int Orthop       Date:  2015-07-07       Impact factor: 3.075

2.  Radiologic assessment of glenohumeral relationship: reliability and reproducibility of lateral humeral offset.

Authors:  Bakir Kadum; Arkan S Sayed-Noor; Nikolaos Perisynakis; Saida Baea; G O Sjödén
Journal:  Surg Radiol Anat       Date:  2015-01-15       Impact factor: 1.246

  2 in total