Literature DB >> 927384

Selective iodine imaging using K-edge energies in computerized x-ray tomography.

S J Riederer, C A Mistretta.   

Abstract

Iodine is commonly used as a contrast material in computerized x-ray tomography. In some cases the determination of the iodine distribution in the image may be prevented by the presence of bone or tissue variations within the tomographic slice. This paper describes a method for quantitative selective imaging of the iodine concentration in the slice. The method employs scans using three heavily filtered x-ray beams, two having mean energies which straddle the iodine K edge (33 keV) and another at a slightly higher energy. The results are independent of tissue and bone over a broad range of projection path lengths. It is shown that, for separation of iodine from one other material, a two-beam K-edge approach requires less integral dose than a two-beam technique at conventional CT energies for slice diameters up to 30 cm. For selective iodine imaging in the presence of more than one other material, the three-spectrum K-edge technique is a necessity. Exposure requirements and beam-hardening corrections are discussed in detail and a computer-simulated CT image generated by the proposed scheme is presented.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 927384     DOI: 10.1118/1.594357

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study.

Authors:  Han Chen; Cheng Xu; Mats Persson; Mats Danielsson
Journal:  J Med Imaging (Bellingham)       Date:  2015-11-06

2.  Material differentiation by dual energy CT: initial experience.

Authors:  Thorsten R C Johnson; Bernhard Krauss; Martin Sedlmair; Michael Grasruck; Herbert Bruder; Dominik Morhard; Christian Fink; Sabine Weckbach; Miriam Lenhard; Bernhard Schmidt; Thomas Flohr; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-12-07       Impact factor: 5.315

3.  K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging.

Authors:  H Ghadiri; M R Ay; M B Shiran; H Soltanian-Zadeh; H Zaidi
Journal:  Br J Radiol       Date:  2013-08-09       Impact factor: 3.039

4.  Diagnostic accuracy of cardiac computed tomography angiography for myocardial infarction.

Authors:  Monvadi B Srichai; Hersh Chandarana; Robert Donnino; Irene Isabel P Lim; Christianne Leidecker; James Babb; Jill E Jacobs
Journal:  World J Radiol       Date:  2013-08-28

5.  Prospects for microcomputerized-tomography using synchrotron radiation.

Authors:  C A Carlsson; G Matscheko; P Spanne
Journal:  Biol Trace Elem Res       Date:  1987-08       Impact factor: 3.738

6.  Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

Authors:  Grace J Gang; Wojciech Zbijewski; J Webster Stayman; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

7.  Clinical potential of retrospective on-demand spectral analysis using dual-layer spectral detector-computed tomography in ischemia complicating small-bowel obstruction.

Authors:  Seitaro Oda; Takeshi Nakaura; Daisuke Utsunomiya; Yoshinori Funama; Narumi Taguchi; Masanori Imuta; Yasunori Nagayama; Yasuyuki Yamashita
Journal:  Emerg Radiol       Date:  2017-05-01

8.  Optimization of K-edge imaging with spectral CT.

Authors:  Peng He; Biao Wei; Wenxiang Cong; Ge Wang
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

9.  Noise suppression for dual-energy CT via penalized weighted least-square optimization with similarity-based regularization.

Authors:  Joseph Harms; Tonghe Wang; Michael Petrongolo; Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

10.  Carotid artery plaque characterization using CT multienergy imaging.

Authors:  L Saba; G M Argiolas; P Siotto; M Piga
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-04       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.