Abstract

PURPOSE: Controlled aliasing techniques for simultaneously acquired echo-planar imaging slices have been shown to significantly increase the temporal efficiency for both diffusion-weighted imaging and functional magnetic resonance imaging studies. The "slice-GRAPPA" (SG) method has been widely used to reconstruct such data. We investigate robust optimization techniques for SG to ensure image reconstruction accuracy through a reduction of leakage artifacts.
METHODS: Split SG is proposed as an alternative kernel optimization method. The performance of Split SG is compared to standard SG using data collected on a spherical phantom and in vivo on two subjects at 3 T. Slice-accelerated and nonaccelerated data were collected for a spin-echo diffusion-weighted acquisition. Signal leakage metrics and time-series SNR were used to quantify the performance of the kernel fitting approaches.
RESULTS: The Split SG optimization strategy significantly reduces leakage artifacts for both phantom and in vivo acquisitions. In addition, a significant boost in time-series SNR for in vivo diffusion-weighted acquisitions with in-plane 2× and slice 3× accelerations was observed with the Split SG approach.
CONCLUSION: By minimizing the influence of leakage artifacts during the training of SG kernels, we have significantly improved reconstruction accuracy. Our robust kernel fitting strategy should enable better reconstruction accuracy and higher slice-acceleration across many applications.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  CAIPIRINHA; leakage; parallel imaging; simultaneous multislice

Mesh:

Year:  2013        PMID: 23963964      PMCID: PMC4364522          DOI: 10.1002/mrm.24898

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Simultaneous echo refocusing in EPI.

Authors:  David A Feinberg; Timothy G Reese; Van J Wedeen
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

4.  SENSE-DTI at 3 T.

Authors:  T Jaermann; G Crelier; K P Pruessmann; X Golay; T Netsch; A M C van Muiswinkel; S Mori; P C M van Zijl; A Valavanis; S Kollias; P Boesiger
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

5.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging.

Authors:  Felix A Breuer; Martin Blaimer; Robin M Heidemann; Matthias F Mueller; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

6.  Accelerated volumetric MRI with a SENSE/GRAPPA combination.

Authors:  Martin Blaimer; Felix A Breuer; Nicole Seiberlich; Matthias F Mueller; Robin M Heidemann; Vladimir Jellus; Graham Wiggins; Lawrence L Wald; Mark A Griswold; Peter M Jakob
Journal:  J Magn Reson Imaging       Date:  2006-08       Impact factor: 4.813

7.  Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI.

Authors:  Steen Moeller; Essa Yacoub; Cheryl A Olman; Edward Auerbach; John Strupp; Noam Harel; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

8.  Simultaneous multislice acquisition of MR images.

Authors:  J B Weaver
Journal:  Magn Reson Med       Date:  1988-11       Impact factor: 4.668

9.  Halving imaging time of whole brain diffusion spectrum imaging and diffusion tractography using simultaneous image refocusing in EPI.

Authors:  Timothy G Reese; Thomas Benner; Ruopeng Wang; David A Feinberg; Van J Wedeen
Journal:  J Magn Reson Imaging       Date:  2009-03       Impact factor: 4.813

10.  Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging.

Authors:  David A Feinberg; Steen Moeller; Stephen M Smith; Edward Auerbach; Sudhir Ramanna; Matthias Gunther; Matt F Glasser; Karla L Miller; Kamil Ugurbil; Essa Yacoub
Journal:  PLoS One       Date:  2010-12-20       Impact factor: 3.240

View more
  81 in total

1.  Transfer learning improves resting-state functional connectivity pattern analysis using convolutional neural networks.

Authors:  Pál Vakli; Regina J Deák-Meszlényi; Petra Hermann; Zoltán Vidnyánszky
Journal:  Gigascience       Date:  2018-12-01       Impact factor: 6.524

2.  High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS).

Authors:  Kawin Setsompop; Qiuyun Fan; Jason Stockmann; Berkin Bilgic; Susie Huang; Stephen F Cauley; Aapo Nummenmaa; Fuyixue Wang; Yogesh Rathi; Thomas Witzel; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

3.  Hybrid-Space SENSE Reconstruction for Simultaneous Multi-Slice MRI.

Authors:  Kangrong Zhu; Robert F Dougherty; Hua Wu; Matthew J Middione; Atsushi M Takahashi; Tao Zhang; John M Pauly; Adam B Kerr
Journal:  IEEE Trans Med Imaging       Date:  2016-02-18       Impact factor: 10.048

4.  Simultaneous Multi-VENC and Simultaneous Multi-Slice Phase Contrast Magnetic Resonance Imaging.

Authors:  Suhyung Park; Liyong Chen; Jennifer Townsend; Hyunyeol Lee; David A Feinberg
Journal:  IEEE Trans Med Imaging       Date:  2019-08-12       Impact factor: 10.048

5.  Linear Predictability in MRI Reconstruction: Leveraging Shift-Invariant Fourier Structure for Faster and Better Imaging.

Authors:  Justin P Haldar; Kawin Setsompop
Journal:  IEEE Signal Process Mag       Date:  2020-01-17       Impact factor: 12.551

6.  Non-Cartesian slice-GRAPPA and slice-SPIRiT reconstruction methods for multiband spiral cardiac MRI.

Authors:  Changyu Sun; Yang Yang; Xiaoying Cai; Michael Salerno; Craig H Meyer; Daniel Weller; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

7.  Iterative correction of RF envelope distortion with GRATER-measured waveforms.

Authors:  Vanessa L Landes; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-08-23       Impact factor: 4.668

8.  Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage.

Authors:  Cornelius Eichner; Kourosh Jafari-Khouzani; Stephen Cauley; Himanshu Bhat; Pavlina Polaskova; Ovidiu C Andronesi; Otto Rapalino; Robert Turner; Lawrence L Wald; Steven Stufflebeam; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2013-10-28       Impact factor: 4.668

9.  Stimulus-Specific Visual Working Memory Representations in Human Cerebellar Lobule VIIb/VIIIa.

Authors:  James A Brissenden; Sean M Tobyne; Mark A Halko; David C Somers
Journal:  J Neurosci       Date:  2020-11-19       Impact factor: 6.167

10.  Separation of parallel encoded complex-valued slices (SPECS) from a single complex-valued aliased coil image.

Authors:  Daniel B Rowe; Iain P Bruce; Andrew S Nencka; James S Hyde; Mary C Kociuba
Journal:  Magn Reson Imaging       Date:  2015-11-21       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.