Literature DB >> 23961066

Patient dose levels for seven different radiographic examination types.

Mohamed Anwar K Abdelhalim1.   

Abstract

This study was carried out as a part of a comprehensive project to establish a national diagnostic reference level (NDRL), for the first time, in Saudi Arabia. Seven of the most common X-ray examinations (10 projections) were included. This study consisted of 200 patients who were referred for X-ray examinations at King Khalid University Hospital (KKUH). The selected X-ray examinations were skull (PA), kub (AP and LAT), ankle (AP and LAT), foot (AP/OBL and LAT/OBL), hib (AP and LAT) and sinuses paranasal (AP). Mean patient information and exposure parameters for these seven radiographic examinations were recorded at KKUH. Some of these radiographic examinations were compared with their corresponding values at other national places [Security Forces Hospital (SFH); King Abdulaziz City for Science and Technology (KACST)] in Saudi Arabia. We found that the patient mean dose values recorded at KKUH were varied from those recorded at other national places. Wide variations in patient dose arising from a specific type of X-ray examination at different national places suggests that significant reductions in patient dose would be possible without affecting image quality. Furthermore, variations in patient dose may emerge from the examination technique, clinical condition, radiologist skill, tube current, tube potential and focus to film distance. The data of this study will be useful for the formulation of NDRLs, and it is also provides local diagnostic reference levels for some diagnostic X-ray examinations at KKUH and other national places in Saudi Arabia.

Entities:  

Keywords:  Harshaw 3500 Reader; National hospitals; Radiographic examinations; Thermoluminescence dosimeters; X-ray

Year:  2010        PMID: 23961066      PMCID: PMC3730880          DOI: 10.1016/j.sjbs.2009.12.013

Source DB:  PubMed          Journal:  Saudi J Biol Sci        ISSN: 1319-562X            Impact factor:   4.219


  11 in total

Review 1.  Diagnostic reference levels in radiology.

Authors:  Euclid Seeram; Patrick C Brennan
Journal:  Radiol Technol       Date:  2006 May-Jun

Review 2.  Effective doses in radiology and diagnostic nuclear medicine: a catalog.

Authors:  Fred A Mettler; Walter Huda; Terry T Yoshizumi; Mahadevappa Mahesh
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

3.  Evaluation of exposure parameters in plain radiography: a comparative study with European guidelines.

Authors:  L Lança; A Silva; E Alves; F Serranheira; M Correia
Journal:  Radiat Prot Dosimetry       Date:  2008-04-22       Impact factor: 0.972

4.  Determination of guidance levels of dose for diagnostic radiography in Taiwan.

Authors:  C J Tung; H Y Tsai; S H Lo; C N Guan; Y B Chen
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

5.  Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals.

Authors:  D A Johnston; P C Brennan
Journal:  Br J Radiol       Date:  2000-04       Impact factor: 3.039

6.  Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures.

Authors:  J T Cusma; M R Bell; M A Wondrow; J P Taubel; D R Holmes
Journal:  J Am Coll Cardiol       Date:  1999-02       Impact factor: 24.094

7.  Local diagnostic reference levels for some common diagnostic X-ray examinations in Tehran county of Iran.

Authors:  Mohammad Taghi Bahreyni Toosi; Mohsen Asadinezhad
Journal:  Radiat Prot Dosimetry       Date:  2007-05-10       Impact factor: 0.972

8.  Doses to patients in routine X-ray examinations in Malaysia.

Authors:  K H Ng; P Rassiah; H B Wang; A S Hambali; P Muthuvellu; H P Lee
Journal:  Br J Radiol       Date:  1998-06       Impact factor: 3.039

9.  Doses to patients in some routine diagnostic X-ray examinations in Iran: proposed the first Iranian diagnostic reference levels.

Authors:  Mohsen Asadinezhad; Mohammad Taghi Bahreyni Toossi
Journal:  Radiat Prot Dosimetry       Date:  2008-12-23       Impact factor: 0.972

10.  Real-time measurement and audit of radiation dose to patients undergoing computed radiography.

Authors:  Eliseo Vano; Jose Miguel Fernandez; Jose Ignacio Ten; Eduardo Guibelalde; Luciano Gonzalez; Cesar S A Pedrosa
Journal:  Radiology       Date:  2002-10       Impact factor: 11.105

View more
  2 in total

1.  Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, Iran.

Authors:  Akbar Aliasgharzadeh; Ehsan Mihandoost; Mahboubeh Masoumbeigi; Morteza Salimian; Mehran Mohseni
Journal:  Glob J Health Sci       Date:  2015-02-24

2.  Development of a Manual Measurement Device for Measuring Hallux Valgus Angle in Patients with Hallux Valgus.

Authors:  Guoli Li; Jinsong Shen; Edward Smith; Chetna Patel
Journal:  Int J Environ Res Public Health       Date:  2022-07-26       Impact factor: 4.614

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.