Literature DB >> 9849390

Doses to patients in routine X-ray examinations in Malaysia.

K H Ng1, P Rassiah, H B Wang, A S Hambali, P Muthuvellu, H P Lee.   

Abstract

A collaborative national survey initiated by the University of Malaya and the Ministry of Health was conducted from 1993 to 1995 to establish baseline patient dose data for seven common types (12 projections) of X-ray examinations in Malaysia. A total of 12 randomly selected public hospitals and 867 patients were included in this survey. The entrance surface doses (ESD) received by the patients were measured using thermoluminescent dosemeters (TLDs) attached to the patient's skin. Histograms are presented showing wide, positively skewed distributions of measured entrance surface doses for each examination. Mean, median, first and third quartile values of ESD and median effective dose are reported. Survey results are generally comparable with those reported in the UK, USA and by the International Atomic Energy Agency (IAEA). The results also provide information on dose level for a lower weight population (mean weight 60 kg) compared with the international reference dose values based on a 70 kg standard. The findings support the importance of the on-going national quality assurance programme to ensure doses are kept to a level consistent with optimum image quality. The data will also be useful for the formulation of national guidance levels as recommended by the IAEA. Furthermore, this study provides patient dosimetry information on healthcare level II countries.

Entities:  

Mesh:

Year:  1998        PMID: 9849390     DOI: 10.1259/bjr.71.846.9849390

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation.

Authors:  M Finnerty; P C Brennan
Journal:  Eur Radiol       Date:  2005-03-24       Impact factor: 5.315

2.  Patient dose levels for seven different radiographic examination types.

Authors:  Mohamed Anwar K Abdelhalim
Journal:  Saudi J Biol Sci       Date:  2010-02-13       Impact factor: 4.219

3.  Evaluation of radiation dose and image quality following changes to tube potential (kVp) in conventional paediatric chest radiography.

Authors:  S Ramanaidu; Rb Sta Maria; Kh Ng; J George; G Kumar
Journal:  Biomed Imaging Interv J       Date:  2006-07-01

4.  Survey of dose area product received by patients undergoing common radiological examinations in four centers in Nigeria.

Authors:  Bidemi I Akinlade; Idowu P Farai; Akintunde A Okunade
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

5.  Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system.

Authors:  Reena Sharma; Sunil Dutt Sharma; Shramika Pawar; Ajay Chaubey; S Kantharia; D A R Babu
Journal:  J Med Phys       Date:  2015 Jan-Mar
  5 in total