Literature DB >> 2394016

Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart.

R C Marshall1, E M Leidholdt, D Y Zhang, C A Barnett.   

Abstract

Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile (Tc-MIBI) and thallium-201 extraction, washout, and retention were investigated and compared in 20 isolated, isovolumic, retrograde blood-perfused rabbit hearts at flow rates ranging from 0.5 to 3.5 ml/g wet wt min-1 in the absence of tracer recirculation. Mean Tc-MIBI peak instantaneous extraction was lower (0.55 +/- 0.10, p less than 0.001) and more affected by flow rate (p less than 0.05) than 201Tl peak instantaneous extraction (0.83 +/- 0.06). In contrast, the rate of 201Tl washout was significantly faster (p less than 0.05) and initially more dependent on perfusion rate (p less than 0.05) than Tc-MIBI washout. Reflecting its higher peak instantaneous extraction, 201Tl retention was 55-79% higher immediately after isotope injection (p less than 0.001) than Tc-MIBI retention, and relative changes in maximal 201Tl net uptake correlated better (p less than 0.05) with relative flow changes than maximal Tc-MIBI net uptake. However, due to its faster washout rate, the superiority of thallium over Tc-MIBI as a perfusion indicator was lost within 10 minutes of tracer injection under the present single-pass experimental conditions. These data were interpreted to indicate that 1) Tc-MIBI is not as well extracted and has a slower washout rate than 201Tl; 2) varying the coronary flow rate has significant but divergent effects on the extraction, washout, and retention of Tc-MIBI and 201Tl; and 3) the present results support continued evaluation of Tc-MIBI as a possible perfusion indicator.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2394016     DOI: 10.1161/01.cir.82.3.998

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  19 in total

1.  Does contrast echocardiography provide new insight regarding regulation of microcirculatory flow and stress perfusion imaging?

Authors:  A J Sinusas; P Kailasnath
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

Review 2.  Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues.

Authors:  P Kailasnath; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

Review 3.  Myocardial perfusion imaging agents: SPECT and PET.

Authors:  George A Beller; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

4.  Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera.

Authors:  Antoine Verger; Laetitia Imbert; Yalcine Yagdigul; Renaud Fay; Wassila Djaballah; François Rouzet; Nicolas Fourquet; Sylvain Poussier; Véronique Roch; Dominique Le Guludec; Gilles Karcher; Pierre-Yves Marie
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-08       Impact factor: 9.236

5.  Quantitative evaluation of manganese-52m as a myocardial perfusion tracer in pigs using positron emission tomography.

Authors:  A Buck; N Nguyen; C Burger; S Ziegler; L Frey; G Weigand; W Erhardt; R Senekowitsch-Schmidtke; R Pellikka; P Bläuenstein; J T Locher; M Schwaiger
Journal:  Eur J Nucl Med       Date:  1996-12

6.  Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast….

Authors:  Milena J Henzlova; W Lane Duvall
Journal:  J Nucl Cardiol       Date:  2015-06       Impact factor: 5.952

7.  A comparison of Tl-201, Tc-99m sestamibi, and Tc-99m tetrofosmin myocardial perfusion scintigraphy in patients with mild to moderate coronary stenosis.

Authors:  Eliana Reyes; Chee Y Loong; Mark Harbinson; Shelley Rahman; Elizabeth Prvulovich; Peter J Ell; Constantinos Anagnostopoulos; S Richard Underwood
Journal:  J Nucl Cardiol       Date:  2006-07       Impact factor: 5.952

8.  Quantification of human and rodent brown adipose tissue function using 99mTc-methoxyisobutylisonitrile SPECT/CT and 18F-FDG PET/CT.

Authors:  Aaron M Cypess; Ashley N Doyle; Christina A Sass; Tian Lian Huang; Peter M Mowschenson; Harold N Rosen; Yu-Hua Tseng; Edwin L Palmer; Gerald M Kolodny
Journal:  J Nucl Med       Date:  2013-09-26       Impact factor: 10.057

9.  Prevalence, location, and extent of significant coronary artery disease in patients with normal myocardial perfusion imaging.

Authors:  Shu Yokota; Jan Paul Ottervanger; Mohamed Mouden; Jorik R Timmer; Siert Knollema; Pieter L Jager
Journal:  J Nucl Cardiol       Date:  2014-01-28       Impact factor: 5.952

10.  Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride.

Authors:  Celine Meyer; Pierre Weinmann
Journal:  J Nucl Cardiol       Date:  2016-04-20       Impact factor: 5.952

View more