Literature DB >> 27098337

Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride.

Celine Meyer1, Pierre Weinmann2.   

Abstract

BACKGROUND: Cadmium-zinc-telluride (CZT) cameras allow to decrease significantly the acquisition time of myocardial perfusion imaging (MPI), but the duration of the examination is still long. Therefore, this study was performed to test the feasibility of early imaging following injection of Tc-99 m sestamibi using a CZT camera.
METHODS: Seventy patients underwent both an early and a delayed image acquisition after exercise stress test (n = 30), dipyridamole stress test (n = 20), and at rest (n = 20). After injection of Tc-99 m sestamibi, the early image acquisition started on average within 5 minutes for the exercise and rest groups, and 3 minutes 30 seconds for the dipyridamole group. Two independent observers evaluated image quality and extracardiac uptake on four-point scales. The difference between early and later images for each patient was scored on a five-point scale.
RESULTS: The image quality and extracardiac uptake of early and delayed image acquisitions were not different for the three groups (P > .05). There was no significant difference between early and delayed image acquisitions in the exercise, dipyridamole, and rest groups, respectively, in 63%, 40%, and 80% of cases. In the exercise group and rest group, a defect was only present in early MPI, respectively, in 13% and 20% of cases. A defect was only present in delayed images in 10% of cases in the exercise group and in 45% of cases in the dipyridamole group.
CONCLUSIONS: There was no difference between early and later image acquisitions in terms of quality. This protocol reduces the length of the procedure for the patient. Beginning with early image acquisitions may help to overcome the artifacts that are observed at the delayed time.

Entities:  

Keywords:  SPECT; Sestamibi; cadmium-zinc-telluride; image quality; myocardial perfusion imaging

Mesh:

Substances:

Year:  2016        PMID: 27098337     DOI: 10.1007/s12350-016-0499-y

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  20 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

2.  A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera.

Authors:  Sanjiv S Gambhir; Daniel S Berman; Jack Ziffer; Michael Nagler; Martin Sandler; Jim Patton; Brian Hutton; Tali Sharir; Shlomo Ben Haim; Simona Ben Haim
Journal:  J Nucl Med       Date:  2009-04       Impact factor: 10.057

3.  Clinical validation of simultaneous dual-isotope myocardial scintigraphy.

Authors:  Pierre Weinmann; Marc Faraggi; Jean Luc Moretti; Pascal Hannequin
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-10-19       Impact factor: 9.236

4.  Early and delayed technetium-99m-tetrofosmin myocardial SPECT compared in normal volunteers.

Authors:  I Matsunari; Y Tanishima; J Taki; K Ono; H Nishide; S Fujino; M Matoba; K Ichiyanagi; N Tonami
Journal:  J Nucl Med       Date:  1996-10       Impact factor: 10.057

5.  Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast….

Authors:  Milena J Henzlova; W Lane Duvall
Journal:  J Nucl Cardiol       Date:  2015-06       Impact factor: 5.952

6.  Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: quantitative results of myocardial perfusion and left ventricular function.

Authors:  Tali Sharir; Piotr J Slomka; Sean W Hayes; Marcelo F DiCarli; Jack A Ziffer; William H Martin; Dalia Dickman; Simona Ben-Haim; Daniel S Berman
Journal:  J Am Coll Cardiol       Date:  2010-05-04       Impact factor: 24.094

7.  Myocardial technetium 99m-labeled sestamibi single-photon emission computed tomographic imaging in the detection of coronary artery disease: comparison between early (15 minutes) and delayed (60 minutes) imaging.

Authors:  R Taillefer; R Lambert; G Bisson; C Benjamin; D C Phaneuf
Journal:  J Nucl Cardiol       Date:  1994 Sep-Oct       Impact factor: 5.952

8.  Feasibility and diagnostic accuracy of a gated SPECT early-imaging protocol: a multicenter study of the Myoview Imaging Optimization Group.

Authors:  Assuero Giorgetti; Massimiliano Rossi; Mario Stanislao; Guido Valle; Pietro Bertolaccini; Alberto Maneschi; Raffaele Giubbini; Maria Luisa De Rimini; Marco Mazzanti; Mario Cappagli; Elisa Milan; Duccio Volterrani; Paolo Marzullo
Journal:  J Nucl Med       Date:  2007-09-14       Impact factor: 10.057

9.  Biokinetics of technetium-99m-tetrofosmin: myocardial perfusion imaging agent: implications for a one-day imaging protocol.

Authors:  D Jain; F J Wackers; J Mattera; M McMahon; A J Sinusas; B L Zaret
Journal:  J Nucl Med       Date:  1993-08       Impact factor: 10.057

10.  High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging.

Authors:  Tali Sharir; Simona Ben-Haim; Konstantine Merzon; Vitali Prochorov; Dalia Dickman; Shlomo Ben-Haim; Daniel S Berman
Journal:  JACC Cardiovasc Imaging       Date:  2008-03
View more
  2 in total

1.  Detection of ischemia with early myocardial perfusion imaging: You see more if you watch before.

Authors:  Riccardo Liga; Alessia Gimelli
Journal:  J Nucl Cardiol       Date:  2016-04-13       Impact factor: 5.952

Review 2.  Review of cardiovascular imaging in the Journal of Nuclear Cardiology in 2017. Part 2 of 2: Myocardial perfusion imaging.

Authors:  Fadi G Hage; Wael A AlJaroudi
Journal:  J Nucl Cardiol       Date:  2018-04-16       Impact factor: 5.952

  2 in total