Literature DB >> 23931961

Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series.

Toshiki Kobayashi1, Michael S Orendurff, David A Boone.   

Abstract

The alignment of a lower-limb prosthesis is critical to the successful prosthetic fitting and utilization by the wearer. Loads generated by the socket applied to the residual limb while walking are thought to be different in transfemoral and knee-disarticulation prostheses. The aim of this case series was to compare the socket reaction moments between transfemoral and knee-disarticulation prostheses and to investigate the effect of alignment changes on them. Two amputees, one with a transfemoral prosthesis and another with a knee-disarticulation prosthesis, participated in this study. A Smart Pyramid™ was used to measure socket reaction moments while walking under 9 selected alignment conditions; including nominally aligned, angle malalignments of 6° (flexion, extension, abduction and adduction) and translation malalignments of 15 mm (anterior, posterior, medial and lateral) of the socket relative to the foot. This study found that the pattern of the socket reaction moments was similar between transfemoral and knee-disarticulation prostheses. An extension moment in the sagittal plane and a varus moment in the coronal plane were dominant during stance under the nominally aligned condition. This study also demonstrated that alignment changes might have consistent effects on the socket reaction moments in transfemoral and knee-disarticulation prostheses. Extension and posterior translation of the socket resulted in increases in an extension moment, while abduction and lateral translation of the socket resulted in increases in a varus moment. The socket reaction moments may potentially serve as useful biomechanical parameters to evaluate alignment in transfemoral and knee-disarticulation prostheses.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Amputation; Ankle; Kinetics; Malalignment; Smart pyramid

Mesh:

Year:  2013        PMID: 23931961      PMCID: PMC3789657          DOI: 10.1016/j.jbiomech.2013.07.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  18 in total

1.  Estimation of forces at the interface between an artificial limb and an implant directly fixed into the femur in above-knee amputees.

Authors:  Paul Stephenson; Bahaa B Seedhom
Journal:  J Orthop Sci       Date:  2002       Impact factor: 1.601

2.  Energy expenditure and biomechanical characteristics of lower limb amputee gait: the influence of prosthetic alignment and different prosthetic components.

Authors:  Thomas Schmalz; Siegmar Blumentritt; Rolf Jarasch
Journal:  Gait Posture       Date:  2002-12       Impact factor: 2.840

3.  Repeatability of a new observational gait score for unilateral lower limb amputees.

Authors:  Susan J Hillman; Stephen C Donald; Janet Herman; Elaine McCurrach; Anthony McGarry; Alison M Richardson; James E Robb
Journal:  Gait Posture       Date:  2010-04-10       Impact factor: 2.840

4.  Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living.

Authors:  Winson C C Lee; Laurent A Frossard; Kerstin Hagberg; Eva Haggstrom; Rickard Brånemark; John H Evans; Mark J Pearcy
Journal:  Clin Biomech (Bristol, Avon)       Date:  2007-04-02       Impact factor: 2.063

5.  Monitoring of the load regime applied on the osseointegrated fixation of a trans-femoral amputee: a tool for evidence-based practice.

Authors:  Laurent Frossard; Nathan Stevenson; James Smeathers; Eva Häggström; Kerstin Hagberg; John Sullivan; David Ewins; David Lee Gow; Steven Gray; Rickard Brånemark
Journal:  Prosthet Orthot Int       Date:  2008-03       Impact factor: 1.895

6.  Loading applied on prosthetic knee of transfemoral amputee: comparison of inverse dynamics and direct measurements.

Authors:  R Dumas; L Cheze; L Frossard
Journal:  Gait Posture       Date:  2009-08-25       Impact factor: 2.840

7.  Effect of transtibial prosthesis alignment changes on out-of-plane socket reaction moments during walking in amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Ming Zhang; David A Boone
Journal:  J Biomech       Date:  2012-09-10       Impact factor: 2.712

8.  Alignment of lower-limb prostheses.

Authors:  M S Zahedi; W D Spence; S E Solomonidis; J P Paul
Journal:  J Rehabil Res Dev       Date:  1986-04

9.  Perception of socket alignment perturbations in amputees with transtibial prostheses.

Authors:  David A Boone; Toshiki Kobayashi; Teri G Chou; Adam K Arabian; Kim L Coleman; Michael S Orendurff; Ming Zhang
Journal:  J Rehabil Res Dev       Date:  2012

Review 10.  Lower-limb deficiencies and amputations in children.

Authors:  J I Krajbich
Journal:  J Am Acad Orthop Surg       Date:  1998 Nov-Dec       Impact factor: 3.020

View more
  4 in total

1.  Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Adam K Arabian; Teri G Rosenbaum-Chou; David A Boone
Journal:  J Biomech       Date:  2014-02-14       Impact factor: 2.712

2.  Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

Authors:  Toshiki Kobayashi; Adam K Arabian; Michael S Orendurff; Teri G Rosenbaum-Chou; David A Boone
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-11-13       Impact factor: 2.063

3.  Deleterious Musculoskeletal Conditions Secondary to Lower Limb Loss: Considerations for Prosthesis-Related Factors.

Authors:  Ashley D Knight; Christopher L Dearth; Brad D Hendershot
Journal:  Adv Wound Care (New Rochelle)       Date:  2020-05-22       Impact factor: 4.730

4.  The relationship between trans-femoral prosthesis alignment and the center trajectory of plantar pressure in the frontal plane.

Authors:  Tomohiro Nomura; Kota Watanabe; Toshiya Nosaka; Hiroyuki Matsubara; Masaharu Akiyama; Kimiharu Inui
Journal:  J Phys Ther Sci       Date:  2016-02-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.