Literature DB >> 12443950

Energy expenditure and biomechanical characteristics of lower limb amputee gait: the influence of prosthetic alignment and different prosthetic components.

Thomas Schmalz1, Siegmar Blumentritt, Rolf Jarasch.   

Abstract

In this study, the influence of different prosthetic alignments and components on oxygen consumption and the important biomechanical characteristics of the normal gait pattern of leg amputees was investigated. With 15 transtibial and 12 transfemoral amputees, the oxygen consumption during walking on a treadmill was analyzed and biomechanical parameters during walking on even ground at a self-selected speed were defined. The amputation of all patients was caused by trauma. Variations of the prosthetic alignment affect the energy consumption of transfemoral amputees more significantly than that of transtibial amputees. Comparison of different prosthetic feet worn by transtibial amputees did not show significant differences regarding metabolic parameters. Compared with conventional hydraulic knee controls, the oxygen consumption of transfemoral amputees provided with an electronically controlled hydraulic knee joint is reduced. All investigated variations can be clearly characterized by the sagittal moments acting on the joints of the prosthetic limb during gait.

Entities:  

Mesh:

Year:  2002        PMID: 12443950     DOI: 10.1016/s0966-6362(02)00008-5

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  51 in total

1.  The effects of alignment of an articulated ankle-foot orthosis on lower limb joint kinematics and kinetics during gait in individuals post-stroke.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Grace Hunt; Fan Gao; Nicholas LeCursi; Lucas S Lincoln; K Bo Foreman
Journal:  J Biomech       Date:  2018-11-22       Impact factor: 2.712

2.  [The influence of the C-leg knee-shin system from the Otto Bock Company in the care of above-knee amputees. A clinical-biomechanical study to define indications].

Authors:  H H Wetz; U Hafkemeyer; B Drerup
Journal:  Orthopade       Date:  2005-04       Impact factor: 1.087

3.  Effect of speed on the energy cost of walking in unilateral traumatic lower limb amputees.

Authors:  Joakim J Genin; Guillaume J Bastien; Bernard Franck; Christine Detrembleur; Patrick A Willems
Journal:  Eur J Appl Physiol       Date:  2008-05-14       Impact factor: 3.078

4.  'Outwalk': a protocol for clinical gait analysis based on inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Alberto Ferrari; Pietro Garofalo; Michele Raggi; Angelo Cappello; Adriano Ferrari
Journal:  Med Biol Eng Comput       Date:  2009-11-13       Impact factor: 2.602

5.  Transfemoral amputations: is there an effect of residual limb length and orientation on energy expenditure?

Authors:  Johanna C Bell; Erik J Wolf; Barri L Schnall; John E Tis; Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2014-10       Impact factor: 4.176

6.  Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses.

Authors:  Peter Gabriel Adamczyk; Michelle Roland; Michael E Hahn
Journal:  Hum Mov Sci       Date:  2017-05-09       Impact factor: 2.161

7.  [Function of prosthesis components in lower limb amputees with bone-anchored percutaneous implants : Biomechanical aspects].

Authors:  S Blumentritt
Journal:  Unfallchirurg       Date:  2017-05       Impact factor: 1.000

Review 8.  Heat-related issues and practical applications for Paralympic athletes at Tokyo 2020.

Authors:  Katy E Griggs; Ben T Stephenson; Michael J Price; Victoria L Goosey-Tolfrey
Journal:  Temperature (Austin)       Date:  2019-06-27

9.  Radiographic parameters improve lower extremity prosthetic alignment.

Authors:  Ryan Mooney; Patrick Carry; Erin Wylie; Abby Schultz; Bryan McNair; Carol Page; Susan Biffl; Travis Heare
Journal:  J Child Orthop       Date:  2013-09-28       Impact factor: 1.548

10.  Energy expenditure and activity of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees.

Authors:  Kenton R Kaufman; James A Levine; Robert H Brey; Shelly K McCrady; Denny J Padgett; Michael J Joyner
Journal:  Arch Phys Med Rehabil       Date:  2008-07       Impact factor: 3.966

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.