Literature DB >> 19709886

Loading applied on prosthetic knee of transfemoral amputee: comparison of inverse dynamics and direct measurements.

R Dumas1, L Cheze, L Frossard.   

Abstract

Inverse dynamics is the most comprehensive method that gives access to the net joint forces and moments during walking. However it is based on assumptions (i.e., rigid segments linked by ideal joints) and it is known to be sensitive to the input data (e.g., kinematic derivatives, positions of joint centres and centre of pressure, inertial parameters). Alternatively, transducers can be used to measure directly the load applied on the residuum of transfemoral amputees. So, the purpose of this study was to compare the forces and moments applied on a prosthetic knee measured directly with the ones calculated by three inverse dynamics computations--corresponding to 3 and 2 segments, and "ground reaction vector technique"--during the gait of one patient. The maximum RMSEs between the estimated and directly measured forces (i.e., 56 N) and moment (i.e., 5 N m) were relatively small. However the dynamic outcomes of the prosthetic components (i.e., absorption of the foot, friction and limit stop of the knee) were only partially assessed with inverse dynamic methods.

Entities:  

Mesh:

Year:  2009        PMID: 19709886     DOI: 10.1016/j.gaitpost.2009.07.126

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  11 in total

1.  Mechanical properties of totally permeable titanium composite pylon for direct skeletal attachment.

Authors:  M Pitkin; J Pilling; G Raykhtsaum
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-01-30       Impact factor: 3.368

2.  Criterion and construct validity of prosthesis-integrated measurement of joint moment data in persons with transtibial amputation.

Authors:  Goeran Fiedler; Brooke Slavens; Roger O Smith; Douglas Briggs; Brian J Hafner
Journal:  J Appl Biomech       Date:  2014-03-04       Impact factor: 1.833

3.  Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Adam K Arabian; Teri G Rosenbaum-Chou; David A Boone
Journal:  J Biomech       Date:  2014-02-14       Impact factor: 2.712

Review 4.  Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review.

Authors:  Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi
Journal:  Biomed Eng Online       Date:  2017-08-18       Impact factor: 2.819

5.  Evaluation of the temporary effect of physical vapor deposition silver coating on resistance to infection in transdermal skin and bone integrated pylon with deep porosity.

Authors:  Maxim A Shevtsov; Natalia M Yudintceva; Miralda I Blinova; Irina V Voronkina; Dmitriy N Suslov; Oleg V Galibin; Dmitriy V Gavrilov; Michael Akkaoui; Grigoriy Raykhtsaum; Andrey V Albul; Emil Pitkin; Mark Pitkin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-03-23       Impact factor: 3.368

6.  Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

Authors:  Toshiki Kobayashi; Adam K Arabian; Michael S Orendurff; Teri G Rosenbaum-Chou; David A Boone
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-11-13       Impact factor: 2.063

7.  Investigation of sit-to-stand and stand-to-sit in an above knee amputee.

Authors:  Fan Gao; Fan Zhang; He Huang
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

8.  Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series.

Authors:  Toshiki Kobayashi; Michael S Orendurff; David A Boone
Journal:  J Biomech       Date:  2013-07-26       Impact factor: 2.712

9.  Walking speed related joint kinetic alterations in trans-tibial amputees: impact of hydraulic 'ankle' damping.

Authors:  Alan R De Asha; Ramesh Munjal; Jai Kulkarni; John G Buckley
Journal:  J Neuroeng Rehabil       Date:  2013-10-17       Impact factor: 4.262

10.  Noncontact Strain Monitoring of Osseointegrated Prostheses.

Authors:  Sumit Gupta; Han-Joo Lee; Kenneth J Loh; Michael D Todd; Joseph Reed; A Drew Barnett
Journal:  Sensors (Basel)       Date:  2018-09-09       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.