Literature DB >> 23912617

Combined use of automatic tube potential selection with tube current modulation and iterative reconstruction technique in coronary CT angiography.

Young Joo Suh1, Young Jin Kim, Sae Rom Hong, Yoo Jin Hong, Hye-Jeong Lee, Jin Hur, Byoung Wook Choi.   

Abstract

PURPOSE: To analyze the effect of automatic tube potential selection with tube current modulation (APSCM) and iterative reconstruction on image quality, diagnostic accuracy, and radiation dose at computed tomographic (CT) angiography and compare it with APSCM-only and body mass index (BMI)-based examination protocols.
MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained from all patients. Images from 185 patients who underwent a BMI-based protocol and 197 patients who underwent an APSCM protocol with filtered back projection (FBP) and an APSCM protocol with sinogram-affirmed iterative reconstruction (SAFIRE) were retrospectively evaluated. Diagnostic performance was compared with that of conventional coronary angiography in a subgroup of 51 patients. Statistical analysis was performed by using the independent or paired t test, Mann-Whitney U test, Wilcoxon signed rank test, χ(2) statistics, linear weighted κ statistics, and generalized estimating equation.
RESULTS: The APSCM group with SAFIRE had a significant reduction in image noise and a significant increase in CT number, contrast enhancement, signal-to-noise ratio, and contrast-to-noise ratio compared with the APSCM group with FBP (P < .0001) and the BMI-based group (P < .001, except P = .002 for image noise). Image quality and diagnostic accuracy showed no significant difference between the three groups. The use of APSCM resulted in a significant reduction in radiation dose compared with the BMI-based protocol.
CONCLUSION: The combination of SAFIRE and APSCM at coronary CT angiography significantly improves objective image quality while maintaining diagnostic accuracy and reduced radiation dose. Online supplemental material is available for this article. © RSNA, 2013.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23912617     DOI: 10.1148/radiol.13130408

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

1.  Factors affecting computed tomography image quality for assessment of mechanical aortic valves.

Authors:  Young Joo Suh; Young Jin Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Sae Rom Hong; Dong Jin Im; Yun Jung Kim; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2015-12-01       Impact factor: 2.357

2.  Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study.

Authors:  Daniela B Husarik; Sebastian T Schindera; Fabian Morsbach; Natalie Chuck; Burkhardt Seifert; Zsolt Szucs-Farkas; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-10-24       Impact factor: 5.315

3.  Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-adapted protocol.

Authors:  Jiyeon Lim; Eun-Ah Park; Whal Lee; Hackjoon Shim; Jin Wook Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-01-22       Impact factor: 2.357

4.  Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography.

Authors:  Long Jiang Zhang; Yining Wang; U Joseph Schoepf; Felix G Meinel; Richard R Bayer; Li Qi; Jian Cao; Chang Sheng Zhou; Yan E Zhao; Xie Li; Jian Bin Gong; Zhengyu Jin; Guang Ming Lu
Journal:  Eur Radiol       Date:  2015-09-17       Impact factor: 5.315

5.  Impact of Reconstruction Algorithms and Gender-Associated Anatomy on Coronary Calcium Scoring with CT: An Anthropomorphic Phantom Study.

Authors:  Qin Li; Songtao Liu; Kyle J Myers; Marios A Gavrielides; Rongping Zeng; Berkman Sahiner; Nicholas Petrick
Journal:  Acad Radiol       Date:  2016-09-22       Impact factor: 3.173

6.  Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique.

Authors:  Ying Wang; Xiaohua Wang; Yan Zhang; Yuliu Lu; Runze Wu; Huishu Yuan
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-29       Impact factor: 2.357

7.  Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types.

Authors:  Young Joo Suh; Young Jin Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Dong Jin Im; Yun Jung Kim; Byoung Wook Choi
Journal:  Korean J Radiol       Date:  2015-08-21       Impact factor: 3.500

8.  Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality.

Authors:  Peijie Lv; Jie Liu; Rui Zhang; Yan Jia; Jianbo Gao
Journal:  Korean J Radiol       Date:  2015-05-13       Impact factor: 3.500

9.  Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial.

Authors:  Dong Jin Im; Yun-Hyeon Kim; Ki Seok Choo; Joon-Won Kang; Jung Im Jung; Yoodong Won; Hyo Rim Kim; Myung Hee Chung; Kyunghwa Han; Byoung Wook Choi
Journal:  Trials       Date:  2016-07-15       Impact factor: 2.279

10.  Effectiveness of automatic tube potential selection with tube current modulation in coronary CT angiography for obese patients: Comparison with a body mass index-based protocol using the propensity score matching method.

Authors:  Hong Seon Lee; Young Joo Suh; Kyunghwa Han; Jin Young Kim; Suyon Chang; Dong Jin Im; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Young Jin Kim; Byoung Wook Choi
Journal:  PLoS One       Date:  2018-01-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.