Literature DB >> 23907210

USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy.

Lester A H Critchley1, Li Huang.   

Abstract

Supra-sternal Doppler (USCOM Ltd., Sydney, Australia) can be used during anaesthesia to measure cardiac output (CO) and related flow parameters. However, before the USCOM can be used routinely, its utility and limitations need to be fully understood and critical information about its use disseminated. In "Window to the Circulation" we use the example of an elderly man undergoing major urological robotic surgery to highlight the utility and limitations of intra-operative USCOM use. USCOM readings were verified against oesophageal Doppler. Despite the lack of major blood loss (<500 ml in 8-h), significant changes in haemodynamics were recorded. CO ranged from 3.2 to 8.3 l/min. The quality of USCOM scans and reliability of data was initially poor, but improved as CO increased as surgery progressed. When USCOM scans became acceptable the correlation with oesophageal Doppler was R(2) = 8.0 (p < 0.001). Several characteristic features of the supra-sternal Doppler scans were identified: Aortic and pulmonary flow waves, valve closure, E and A waves, false A-wave and aberrant arterial flow patterns. Their identification helped with identifying the main flow signal across the aortic valve. The USCOM has the potential to monitor changes in CO and related flow parameters intra-operatively and thus help the anaesthetist to more fully understand the patient's haemodynamics. However, achieving a good quality scan is important as it improves the reliability of USCOM data. The supra-sternal route is rich in flow signals and identifying the aortic valve signal is paramount. Recognizing the other characteristic waveforms in the signal helps greatly.

Entities:  

Mesh:

Year:  2013        PMID: 23907210     DOI: 10.1007/s10877-013-9499-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  20 in total

Review 1.  Noninvasive cardiac output monitors: a state-of the-art review.

Authors:  Paul E Marik
Journal:  J Cardiothorac Vasc Anesth       Date:  2012-05-19       Impact factor: 2.628

Review 2.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

Review 3.  A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients.

Authors:  Mark A Hamilton; Maurizio Cecconi; Andrew Rhodes
Journal:  Anesth Analg       Date:  2010-10-21       Impact factor: 5.108

4.  Pulmonary artery catheters: evolving rates and reasons for use.

Authors:  Karen K Y Koo; Jack C J Sun; Qi Zhou; Gordan Guyatt; Deborah J Cook; Stephen D Walter; Maureen O Meade
Journal:  Crit Care Med       Date:  2011-07       Impact factor: 7.598

5.  Study to determine the repeatability of supra-sternal Doppler (ultrasound cardiac output monitor) during general anaesthesia: effects of scan quality, flow volume, and increasing age.

Authors:  L Huang; L A H Critchley
Journal:  Br J Anaesth       Date:  2013-07-23       Impact factor: 9.166

Review 6.  A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM).

Authors:  S W Chong; P J Peyton
Journal:  Anaesthesia       Date:  2012-08-29       Impact factor: 6.955

7.  Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs.

Authors:  Lester A Critchley; Zhi Y Peng; Benny S Fok; Anna Lee; Robert A Phillips
Journal:  Anesth Analg       Date:  2005-03       Impact factor: 5.108

8.  Haemodynamic effects from aortocaval compression at different angles of lateral tilt in non-labouring term pregnant women.

Authors:  S W Y Lee; K S Khaw; W D Ngan Kee; T Y Leung; L A H Critchley
Journal:  Br J Anaesth       Date:  2012-10-11       Impact factor: 9.166

9.  The extraperitoneal approach and subcutaneous emphysema are associated with greater absorption of carbon dioxide during laparoscopic renal surgery.

Authors:  J S Wolf; T G Monk; E M McDougall; B L McClennan; R V Clayman
Journal:  J Urol       Date:  1995-09       Impact factor: 7.450

Review 10.  Esophageal Doppler: noninvasive cardiac output monitor.

Authors:  Bernard P Cholley; Mervyn Singer
Journal:  Echocardiography       Date:  2003-11       Impact factor: 1.724

View more
  3 in total

1.  The effect of head up tilting on bioreactance cardiac output and stroke volume readings using suprasternal transcutaneous Doppler as a control in healthy young adults.

Authors:  Jie Zhang; Lester A H Critchley; Daniel C W Lee; Kim S Khaw; Shara W Y Lee
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Does using two Doppler cardiac output monitors in tandem provide a reliable trend line of changes for validation studies?

Authors:  Huang Li; Lester A H Critchley; Jie Zhang
Journal:  J Clin Monit Comput       Date:  2015-08-28       Impact factor: 2.502

Review 3.  Year in review in journal of clinical monitoring and computing 2014: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Lester Critchley
Journal:  J Clin Monit Comput       Date:  2015-03-05       Impact factor: 2.502

  3 in total