PURPOSE: To investigate the efficacy of a novel respiratory motion scheme, where only the center of k-space is gated using respiratory navigators, versus a fully respiratory-gated acquisition for three-dimensional flow imaging. METHODS: Three-dimensional flow images were acquired axially using a gradient echo sequence in a volume, covering the ascending and descending aorta, and the pulmonary artery bifurcation in 12 healthy subjects (33.2 ± 15.8 years; five men). For respiratory motion compensation, two gating and tracking strategies were used with a 7-mm gating window: (1) All of k-space acquired within the gating window (fully gated) and (2) central k-space acquired within the gating window, and the remainder of k-space acquired without any gating (center gated). Each scan was repeated twice. Stroke volume, mean flow, peak velocity, and signal-to-noise-ratio measurements were performed both on the ascending and on the descending aorta for all acquisitions, which were compared using a linear mixed-effects model and Bland-Altman analysis. RESULTS: There were no statistical differences between the fully gated and the center-gated strategies for the quantification of stroke volume, peak velocity, and mean flow, as well as the signal-to-noise-ratio measurements. Furthermore, the proposed center-gated strategy had significantly shorter acquisition time compared to the fully gated strategy (13:19 ± 3:02 vs. 19:35 ± 5:02, P < 0.001). CONCLUSIONS: The proposed novel center-gated strategy for three-dimensional flow MRI allows for markedly shorter acquisition time without any systematic variation in quantitative flow measurements in this small group of healthy volunteers.
PURPOSE: To investigate the efficacy of a novel respiratory motion scheme, where only the center of k-space is gated using respiratory navigators, versus a fully respiratory-gated acquisition for three-dimensional flow imaging. METHODS: Three-dimensional flow images were acquired axially using a gradient echo sequence in a volume, covering the ascending and descending aorta, and the pulmonary artery bifurcation in 12 healthy subjects (33.2 ± 15.8 years; five men). For respiratory motion compensation, two gating and tracking strategies were used with a 7-mm gating window: (1) All of k-space acquired within the gating window (fully gated) and (2) central k-space acquired within the gating window, and the remainder of k-space acquired without any gating (center gated). Each scan was repeated twice. Stroke volume, mean flow, peak velocity, and signal-to-noise-ratio measurements were performed both on the ascending and on the descending aorta for all acquisitions, which were compared using a linear mixed-effects model and Bland-Altman analysis. RESULTS: There were no statistical differences between the fully gated and the center-gated strategies for the quantification of stroke volume, peak velocity, and mean flow, as well as the signal-to-noise-ratio measurements. Furthermore, the proposed center-gated strategy had significantly shorter acquisition time compared to the fully gated strategy (13:19 ± 3:02 vs. 19:35 ± 5:02, P < 0.001). CONCLUSIONS: The proposed novel center-gated strategy for three-dimensional flow MRI allows for markedly shorter acquisition time without any systematic variation in quantitative flow measurements in this small group of healthy volunteers.
Authors: A V Barger; D C Peters; W F Block; K K Vigen; F R Korosec; T M Grist; C A Mistretta Journal: Magn Reson Med Date: 2000-04 Impact factor: 4.668
Authors: Christof Baltes; Sebastian Kozerke; Michael S Hansen; Klaas P Pruessmann; Jeffrey Tsao; Peter Boesiger Journal: Magn Reson Med Date: 2005-12 Impact factor: 4.668
Authors: Michael Markl; Frandics P Chan; Marcus T Alley; Kris L Wedding; Mary T Draney; Chris J Elkins; David W Parker; Ryan Wicker; Charles A Taylor; Robert J Herfkens; Norbert J Pelc Journal: J Magn Reson Imaging Date: 2003-04 Impact factor: 4.813
Authors: Yilin Liu; Xiaodong Zhong; Brian G Czito; Manisha Palta; Mustafa R Bashir; Brian M Dale; Fang-Fang Yin; Jing Cai Journal: Med Phys Date: 2017-01-25 Impact factor: 4.071
Authors: Joseph Y Cheng; Kate Hanneman; Tao Zhang; Marcus T Alley; Peng Lai; Jonathan I Tamir; Martin Uecker; John M Pauly; Michael Lustig; Shreyas S Vasanawala Journal: J Magn Reson Imaging Date: 2015-12-09 Impact factor: 4.813