Literature DB >> 16276492

Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE.

Christof Baltes1, Sebastian Kozerke, Michael S Hansen, Klaas P Pruessmann, Jeffrey Tsao, Peter Boesiger.   

Abstract

Conventional phase-contrast velocity mapping in the ascending aorta was combined with k-t BLAST and k-t SENSE. Up to 5.3-fold net acceleration was achieved, enabling single breath-hold acquisitions. A standard phase-contrast (PC) sequence with interleaved acquisition of the velocity-encoded segments was modified to collect data in 2 stages, a high-resolution under sampled and a low-resolution fully sampled training stage. In addition, a modification of the k-t reconstruction strategy was tested. This strategy, denoted as "plug-in," incorporates data acquired in the training stage into the final reconstruction for improved data consistency, similar to conventional keyhole. "k-t SENSE plug-in" was found to provide best image quality and most accurate flow quantification. For this strategy, at least 10 training profiles are required to yield accurate stroke volumes (relative deviation <5%) and good image quality. In vivo 2D cine velocity mapping was performed in 6 healthy volunteers with 30-32 cardiac phases (spatial resolution 1.3 x 1.3 x 8-10 mm(3), temporal resolution of 18-38 ms), yielding relative stroke volumes of 106 +/- 18% (mean +/- 2*SD) and 112 +/- 15% for 3.8 x and 5.3 x net accelerations, respectively. In summary, k-t BLAST and k-t SENSE are promising approaches that permit significant scan-time reduction in PC velocity mapping, thus making high-resolution breath-held flow quantification possible.

Entities:  

Mesh:

Year:  2005        PMID: 16276492     DOI: 10.1002/mrm.20730

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  49 in total

1.  In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI.

Authors:  Fabian Rengier; Michael Delles; Roland Unterhinninghofen; Sebastian Ley; Matthias Müller-Eschner; Sasan Partovi; Philipp Geisbüsch; Rüdiger Dillmann; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

Review 2.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

3.  k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements.

Authors:  Emilie Bollache; Alex J Barker; Ryan Scott Dolan; James C Carr; Pim van Ooij; Rouzbeh Ahmadian; Alex Powell; Jeremy D Collins; Julia Geiger; Michael Markl
Journal:  Magn Reson Med       Date:  2017-03-07       Impact factor: 4.668

4.  Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Hyungkyu Huh; Christoph Forman; Alireza Vali; Andreas Greiser; James Carr; Susanne Schnell; Alex J Barker; Ning Jin
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

5.  Dampening of blood-flow pulsatility along the carotid siphon: does form follow function?

Authors:  T Schubert; F Santini; A F Stalder; J Bock; S Meckel; L Bonati; M Markl; S Wetzel
Journal:  AJNR Am J Neuroradiol       Date:  2011-04-07       Impact factor: 3.825

6.  Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Authors:  Albert Hsiao; Ufra Yousaf; Marcus T Alley; Michael Lustig; Frandics Pak Chan; Beverley Newman; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

7.  In vivo hemodynamic analysis of intracranial aneurysms obtained by magnetic resonance fluid dynamics (MRFD) based on time-resolved three-dimensional phase-contrast MRI.

Authors:  Haruo Isoda; Yasuhide Ohkura; Takashi Kosugi; Masaya Hirano; Hiroyasu Takeda; Hisaya Hiramatsu; Shuhei Yamashita; Yasuo Takehara; Marcus T Alley; Roland Bammer; Norbert J Pelc; Hiroki Namba; Harumi Sakahara
Journal:  Neuroradiology       Date:  2009-12-11       Impact factor: 2.804

8.  Accelerated aortic flow assessment with compressed sensing with and without use of the sparsity of the complex difference image.

Authors:  Yongjun Kwak; Seunghoon Nam; Mehmet Akçakaya; Tamer A Basha; Beth Goddu; Warren J Manning; Vahid Tarokh; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-10-12       Impact factor: 4.668

Review 9.  Image reconstruction: an overview for clinicians.

Authors:  Michael S Hansen; Peter Kellman
Journal:  J Magn Reson Imaging       Date:  2014-06-25       Impact factor: 4.813

10.  Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions.

Authors:  Lau Brix; Steffen Ringgaard; Allan Rasmusson; Thomas Sangild Sørensen; W Yong Kim
Journal:  J Cardiovasc Magn Reson       Date:  2009-02-20       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.