Literature DB >> 29855788

Does oversizing an uncemented cup increase post-operative pain in primary total hip arthroplasty?

Jonathan A Barrow1, Hiren M Divecha2, Sunil Panchani2, Richard Boden3, Martyn L Porter2, Tim N Board2.   

Abstract

INTRODUCTION: It has been suggested that one of the factors related to persistent post-operative pain following total hip arthroplasty (THA) is to over sizing of the acetabular component. In order to investigate this potential issue, we retrospectively analysed a series of consecutive uncemented THA. We assessed the incidence of persistent post-operative pain and the size difference between the implanted acetabular component and the native femoral head.
METHODS: A total of 265 consecutive THAs were retrospectively identified. Standardised pre-operative radiographs were analysed using validated techniques to determine the native femoral head diameter. Post-operative standardised radiographs were reviewed and the acetabular orientation determined. Patients were sent postal questionnaires regarding their outcome and level of pain.
RESULTS: Questionnaires were returned by 169 patients (189 hips, 71% response rate). A total of 17 were excluded due to inadequate radiographs., leaving 172 THA in the study group. The mean native femoral head (NFH) size was 47 mm. The most common implanted acetabular component size was 52 mm. The mean difference in cup to NFH diameter (delta) was 5.7 mm (range - 6.1 to 15.4 mm; 95% CI 5.3-6.2 mm). A delta of > 6 mm was found to be significant for predicting persistent post-operative pain (RR = 1.81; 95% CI 1.1-3.1; P = 0.027).
CONCLUSION: Our study confirms that a delta of > 6 mm is associated with an increased risk of persistent post-operative pain following THA. We recommend pre-operative templating in all uncemented THA to ensure the planned acetabular component is no more than 6 mm larger than the NFH diameter.

Entities:  

Keywords:  Arthroplasty; Ceramic; Hip; Oversize; Pain; Uncemented

Mesh:

Year:  2018        PMID: 29855788     DOI: 10.1007/s00590-018-2240-9

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  6 in total

Review 1.  Groin pain after replacement of the hip: aetiology, evaluation and treatment.

Authors:  R A Henderson; P F Lachiewicz
Journal:  J Bone Joint Surg Br       Date:  2012-02

2.  Placement of the acetabular component.

Authors:  D E Beverland; C K J O'Neill; M Rutherford; D Molloy; J C Hill
Journal:  Bone Joint J       Date:  2016-01       Impact factor: 5.082

3.  A new technique for radiographic measurement of acetabular cup orientation.

Authors:  Brian Derbyshire; Peter J Diggle; Christopher J Ingham; Rory Macnair; James Wimhurst; Henry Wynn Jones
Journal:  J Arthroplasty       Date:  2013-07-27       Impact factor: 4.757

4.  Response rates to mail surveys published in medical journals.

Authors:  D A Asch; M K Jedrziewski; N A Christakis
Journal:  J Clin Epidemiol       Date:  1997-10       Impact factor: 6.437

5.  Oversized cups as a major risk factor of postoperative pain after total hip arthroplasty.

Authors:  Guillaume A Odri; Giovany B Padiolleau; François T Gouin
Journal:  J Arthroplasty       Date:  2013-08-06       Impact factor: 4.757

6.  What proportion of patients report long-term pain after total hip or knee replacement for osteoarthritis? A systematic review of prospective studies in unselected patients.

Authors:  Andrew David Beswick; Vikki Wylde; Rachael Gooberman-Hill; Ashley Blom; Paul Dieppe
Journal:  BMJ Open       Date:  2012-02-22       Impact factor: 2.692

  6 in total