Literature DB >> 23892956

Fiducial markers for image-guided partial breast irradiation.

Marco Trovo1, Jerry Polesel, Cristina Biasutti, Giovanna Sartor, Mario Roncadin, Gaetano Mauro Trovo.   

Abstract

PURPOSE: This study was undertaken to study the role of fiducial markers for image-guided partial breast irradiation (IG-PBI), and to compare the shifts based on bony anatomy and fiducial markers.
MATERIALS AND METHODS: Fifteen patients underwent IGPBI. Three fiducial markers were placed in the tumour bed at the time of surgery. Daily orthogonal anterior/ posterior and lateral kV-images were taken before each fraction and compared with the digitally-reconstructed radiographs, both using bony landmarks and fiducial markers as reference. The Student's t test was used to detect a meaningful difference of 3 mm in between the two methods.
RESULTS: A total of 105 image-guided radiation therapy (IGRT) sessions were obtained. The mean superior/inferior, right/left, and anterior/posterior shifts obtained using the bony landmarks vs. the fiducial markers were 2 mm [standard deviation (SD) 10 mm] vs. 0 mm (SD 7 mm), 0 mm (SD 7 mm) vs. 1 mm (SD 4 mm), and 1 mm (SD 7 mm) vs. 0 mm (SD 5 mm), respectively. The mean shift differences in absolute value between the two methods, along the superior/inferior, right/left and anterior/posterior directions were 5 mm (p=0.001), 3 mm [p=not significant (ns)], and 3 mm (p=ns), respectively.
CONCLUSIONS: Fiducial markers for IG-PBI increase set-up accuracy compared to the bony landmarks, in particular along the superior/inferior direction.

Entities:  

Mesh:

Year:  2013        PMID: 23892956     DOI: 10.1007/s11547-013-0967-2

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  7 in total

1.  Cone beam computed tomography guidance for setup of patients receiving accelerated partial breast irradiation.

Authors:  Elizabeth A White; John Cho; Katherine A Vallis; Michael B Sharpe; Grace Lee; Helen Blackburn; Tahani Nageeti; Carol McGibney; David A Jaffray
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-06       Impact factor: 7.038

Review 2.  Image-guided radiotherapy: rationale, benefits, and limitations.

Authors:  Laura A Dawson; Michael B Sharpe
Journal:  Lancet Oncol       Date:  2006-10       Impact factor: 41.316

3.  Ongoing clinical experience utilizing 3D conformal external beam radiotherapy to deliver partial-breast irradiation in patients with early-stage breast cancer treated with breast-conserving therapy.

Authors:  Frank A Vicini; Vincent Remouchamps; Michelle Wallace; Michael Sharpe; Julie Fayad; Laura Tyburski; Nicola Letts; Larry Kestin; Gregory Edmundson; Jane Pettinga; Neal S Goldstein; John Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-12-01       Impact factor: 7.038

4.  Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer.

Authors:  Bernard Fisher; Stewart Anderson; John Bryant; Richard G Margolese; Melvin Deutsch; Edwin R Fisher; Jong-Hyeon Jeong; Norman Wolmark
Journal:  N Engl J Med       Date:  2002-10-17       Impact factor: 91.245

5.  Twenty-year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer.

Authors:  Umberto Veronesi; Natale Cascinelli; Luigi Mariani; Marco Greco; Roberto Saccozzi; Alberto Luini; Marisel Aguilar; Ettore Marubini
Journal:  N Engl J Med       Date:  2002-10-17       Impact factor: 91.245

6.  Accelerated partial breast irradiation using 3D conformal radiation therapy (3D-CRT).

Authors:  Kathy L Baglan; Michael B Sharpe; David Jaffray; Robert C Frazier; Julie Fayad; Larry L Kestin; Vincent Remouchamps; Alvaro A Martinez; John Wong; Frank A Vicini
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-02-01       Impact factor: 7.038

7.  Clinical experience with image-guided radiotherapy in an accelerated partial breast intensity-modulated radiotherapy protocol.

Authors:  Charles E Leonard; Michael Tallhamer; Tim Johnson; Kari Hunter; Kathryn Howell; Jane Kercher; Jodi Widener; Terese Kaske; Devchand Paul; Scot Sedlacek; Dennis L Carter
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-05-19       Impact factor: 7.038

  7 in total
  4 in total

1.  A topology-based method to mitigate the dosimetric uncertainty caused by the positional variation of the boost volume in breast conservative radiotherapy.

Authors:  Peng-Yi Lee; Chih-Yuan Lin; Shang-Wen Chen; Chun-Ru Chien; Chun-Nan Chu; Hsiu-Ting Hsu; Ji-An Liang; Ying-Jun Lin; An-Cheng Shiau
Journal:  Radiat Oncol       Date:  2017-03-20       Impact factor: 3.481

2.  Seven fractions to deliver partial breast irradiation: the toxicity is Low.

Authors:  Marco Trovo; Michele Avanzo; Lorenzo Vinante; Carlo Furlan; Francesco Fiorica; Tiziana Perin; Loredana Militello; Simon Spazzapan; Massimiliano Berretta; Rajesh Jena; Joseph Stancanello; Erica Piccoli; Mario Mileto; Elvia Micheli; Mario Roncadin; Samuele Massarut
Journal:  Radiat Oncol       Date:  2017-05-23       Impact factor: 3.481

3.  A novel, adaptable, radiographically opaque, multi-plane continuous filament marker for optimizing tissue identification, radiation planning, and radiographic follow-up.

Authors:  Sunny Mitchell; Henry Lee; Beth Baughman DuPree; David C Beyer; Michael Ulissey; Stephen R Grobmyer; Jennifer Gass; Susan Boolbol; Toni Storm-Dickerson
Journal:  Gland Surg       Date:  2019-12

4.  Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation.

Authors:  Xin Zhen; Bo Zhao; Zhuoyu Wang; Robert Timmerman; Ann Spangler; Nathan Kim; Asal Rahimi; Xuejun Gu
Journal:  Radiat Oncol       Date:  2017-09-11       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.