Literature DB >> 17418964

Cone beam computed tomography guidance for setup of patients receiving accelerated partial breast irradiation.

Elizabeth A White1, John Cho, Katherine A Vallis, Michael B Sharpe, Grace Lee, Helen Blackburn, Tahani Nageeti, Carol McGibney, David A Jaffray.   

Abstract

PURPOSE: To evaluate the role of cone-beam CT (CBCT) guidance for setup error reduction and soft tissue visualization in accelerated partial breast irradiation (APBI). METHODS AND MATERIALS: Twenty patients were recruited for the delivery of radiotherapy to the postoperative cavity (3850 cGy in 10 fractions over 5 days) using an APBI technique. Cone-beam CT data sets were acquired after an initial skin-mark setup and before treatment delivery. These were registered online using the ipsilateral lung and external contours. Corrections were executed for translations exceeding 3 mm. The random and systematic errors associated with setup using skin-marks and setup using CBCT guidance were calculated and compared.
RESULTS: A total of 315 CBCT data sets were analyzed. The systematic errors for the skin-mark setup were 2.7, 1.7, and 2.4 mm in the right-left, anterior-posterior, and superior-inferior directions, respectively. These were reduced to 0.8, 0.7, and 0.8 mm when CBCT guidance was used. The random errors were reduced from 2.4, 2.2, and 2.9 mm for skin-marks to 1.5, 1.5, and 1.6 mm for CBCT guidance in the right-left, anterior-posterior, and superior-inferior directions, respectively.
CONCLUSION: A skin-mark setup for APBI patients is sufficient for current planning target volume margins for the population of patients studied here. Online CBCT guidance minimizes the occurrence of large random deviations, which may have a greater impact for the accelerated fractionation schedule used in APBI. It is also likely to permit a reduction in planning target volume margins and provide skin-line visualization and dosimetric evaluation of cardiac and lung volumes.

Entities:  

Mesh:

Year:  2007        PMID: 17418964     DOI: 10.1016/j.ijrobp.2007.01.048

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  23 in total

1.  Fiducial markers for image-guided partial breast irradiation.

Authors:  Marco Trovo; Jerry Polesel; Cristina Biasutti; Giovanna Sartor; Mario Roncadin; Gaetano Mauro Trovo
Journal:  Radiol Med       Date:  2013-07-25       Impact factor: 3.469

Review 2.  Partial breast irradiation: a review of techniques and indications.

Authors:  A J Stewart; A J Khan; P M Devlin
Journal:  Br J Radiol       Date:  2010-03-11       Impact factor: 3.039

3.  Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation.

Authors:  D S Yang; W S Yoon; S Y Chung; J A Lee; S Lee; Y J Park; C Y Kim; G S Son
Journal:  Strahlenther Onkol       Date:  2013-02-28       Impact factor: 3.621

4.  Setup accuracy for prone and supine whole breast irradiation.

Authors:  Thomas Mulliez; Akos Gulyban; Tom Vercauteren; Annick van Greveling; Bruno Speleers; Wilfried De Neve; Liv Veldeman
Journal:  Strahlenther Onkol       Date:  2016-02-10       Impact factor: 3.621

5.  Initial validation and clinical experience with 3D optical-surface-guided whole breast irradiation of breast cancer.

Authors:  S Li; T DeWeese; B Movsas; Dezhi Liu; Deborah Frassica; Jinkoo Kim; Qing Chen; Eleanor Walker
Journal:  Technol Cancer Res Treat       Date:  2012-02

6.  Residual image registration error by fiducial markers in accelerated partial breast irradiation using C-arm linac: a phantom study.

Authors:  Ryohei Yamauchi; Natsuki Murayoshi; Shinobu Akiyama; Norifumi Mizuno; Tomoyuki Masuda; Tomoko Itazawa; Jiro Kawamori
Journal:  Phys Eng Sci Med       Date:  2022-06-03

7.  Impact of residual and intrafractional errors on strategy of correction for image-guided accelerated partial breast irradiation.

Authors:  Gang Cai; Wei-Gang Hu; Jia-Yi Chen; Xiao-Li Yu; Zi-Qiang Pan; Zhao-Zhi Yang; Xiao-Mao Guo; Zhi-Min Shao; Guo-Liang Jiang
Journal:  Radiat Oncol       Date:  2010-10-26       Impact factor: 3.481

8.  Comparing digital tomosynthesis to cone-beam CT for position verification in patients undergoing partial breast irradiation.

Authors:  Junan Zhang; Q Jackie Wu; Devon J Godfrey; Toyosi Fatunase; Lawrence B Marks; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-01-08       Impact factor: 7.038

9.  Optimization of Adjuvant Radiation in Breast Conservation Therapy: Can We Minimize without Compromise?

Authors:  Sophia M Edwards-Bennett; Candace R Correa; Eleanor E Harris
Journal:  Int J Breast Cancer       Date:  2011-10-05

10.  Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT.

Authors:  Wei Wang; Jian Bin Li; Hong Guang Hu; Tao Sun; Min Xu; Ting Yong Fan; Qian Shao
Journal:  J Radiat Res       Date:  2013-01-24       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.