INTRODUCTION: The purpose of this study was to analyze explanted PEEK rod spinal systems in the context of their clinical indications. We evaluated damage to the implant and histological changes in explanted periprosthetic tissues. METHODS: 12 patients implanted with 23 PEEK rods were revised between 2008 and 2012. PEEK rods were of the same design (CD Horizon Legacy, Medtronic, Memphis TN, USA). Retrieved components were assessed for surface damage mechanisms, including plastic deformation, scratching, burnishing, and fracture. Patient history and indications for PEEK rod implantation were obtained from analysis of the medical records. RESULTS: 11/12 PEEK rod systems were employed for fusion at one level, and motion preservation at the adjacent level. Surgical complications in the PEEK cohort included a small dural tear in one case that was immediately repaired. There were no cases of PEEK rod fracture or pedicle screw fracture. Retrieved PEEK rods exhibited scratching, as well as impressions from the set screws and pedicle screw saddles. PEEK debris was observed in two patient tissues, which were located adjacent to PEEK rods with evidence of scratching and burnishing. CONCLUSION: This study documents the surface changes and tissue reactions for retrieved PEEK rod stabilization systems. Permanent indentations by the set screws and pedicle screws were the most prevalent observations on the surface of explanted PEEK rods.
INTRODUCTION: The purpose of this study was to analyze explanted PEEK rod spinal systems in the context of their clinical indications. We evaluated damage to the implant and histological changes in explanted periprosthetic tissues. METHODS: 12 patients implanted with 23 PEEK rods were revised between 2008 and 2012. PEEK rods were of the same design (CD Horizon Legacy, Medtronic, Memphis TN, USA). Retrieved components were assessed for surface damage mechanisms, including plastic deformation, scratching, burnishing, and fracture. Patient history and indications for PEEK rod implantation were obtained from analysis of the medical records. RESULTS: 11/12 PEEK rod systems were employed for fusion at one level, and motion preservation at the adjacent level. Surgical complications in the PEEK cohort included a small dural tear in one case that was immediately repaired. There were no cases of PEEK rod fracture or pedicle screw fracture. Retrieved PEEK rods exhibited scratching, as well as impressions from the set screws and pedicle screw saddles. PEEK debris was observed in two patient tissues, which were located adjacent to PEEK rods with evidence of scratching and burnishing. CONCLUSION: This study documents the surface changes and tissue reactions for retrieved PEEK rod stabilization systems. Permanent indentations by the set screws and pedicle screws were the most prevalent observations on the surface of explanted PEEK rods.
Authors: Matthew F Gornet; Frank W Chan; John C Coleman; Brian Murrell; Russ P Nockels; Brett A Taylor; Todd H Lanman; Jorge A Ochoa Journal: J Biomech Eng Date: 2011-08 Impact factor: 2.097
Authors: Allyson Ianuzzi; Steven M Kurtz; William Kane; Priyanka Shah; Ryan Siskey; Andre van Ooij; Rajesh Bindal; Raymond Ross; Todd Lanman; Karin Büttner-Janz; Jorge Isaza Journal: Spine (Phila Pa 1976) Date: 2010-11-01 Impact factor: 3.468
Authors: Stephane Aunoble; Robert Meyrat; Yasser Al Sawad; C Tournier; Philip Leijssen; Jean-Charles Le Huec Journal: Eur Spine J Date: 2009-11-04 Impact factor: 3.134
Authors: Ravi K Ponnappan; Hassan Serhan; Brett Zarda; Ravi Patel; Todd Albert; Alexander R Vaccaro Journal: Spine J Date: 2008-10-01 Impact factor: 4.166
Authors: Jan Siewe; Christina Otto; Peter Knoell; Marco Koriller; Gregor Stein; Thomas Kaulhausen; Peer Eysel; Kourosh Zarghooni; Jeremy Franklin; Rolf Sobottke Journal: BMC Musculoskelet Disord Date: 2011-10-18 Impact factor: 2.362
Authors: Ioannis D Gelalis; Dimitrios V Papadopoulos; Dionysios K Giannoulis; Andreas G Tsantes; Anastasios V Korompilias Journal: Eur J Orthop Surg Traumatol Date: 2017-10-06
Authors: Ronja A Schierjott; Alexander Giurea; Hans-Joachim Neuhaus; Jens Schwiesau; Andreas M Pfaff; Sandra Utzschneider; Gianluca Tozzi; Thomas M Grupp Journal: Biomed Res Int Date: 2016-12-22 Impact factor: 3.411
Authors: Donita I Bylski-Austrow; David L Glos; Anne C Bonifas; Max F Carvalho; Matthew C Coombs; Peter F Sturm Journal: Scoliosis Spinal Disord Date: 2016-09-23