Comparison of glucose determinations on blood samples collected in three types of tubes.

Geling Li1, Michael Cabanero, Zhenglong Wang, Huiying Wang, Tao Huang, Herol Alexis, Ikram Eid, Gilad Muth, Matthew R Pincus.   

Abstract

Because of the metabolism of serum glucose in collection tubes containing blood samples, serum glucose levels may be found to decrease over time. Several types of collection tubes have been designed to, at least partially, block glucose metabolism by red blood cells in blood collection tubes that may not be analyzed immediately after blood collection. These include red-top collection tubes with serum separator, grey-top tubes with a fluoride glycolysis inhibitor, and heparin-containing green-top tubes which prevent clot formation. As part of a quality assurance project, we investigated whether glucose levels differed in the three tube types from each of 18 volunteers on a prolonged standing of 4 hours. We then determined the glucose concentrations of all three tubes from each of the 18 volunteers. We used refrigerated samples over a five-day period to determine if the initial values were reproducible. Surprisingly, after standing for four hours at room temperature, we found that the glucose levels in the three tubes from each volunteer were statistically indistinguishable from one another using the two-tailed paired t-test. Also, a linear regression analysis showed that the values of glucose for the three pairs of two tube types were closely correlated with one another, with correlation coefficients of >0.97, slopes close to 1, and Y-intercepts close to 0. These results suggest that blood collection in any of these tubes will render similar values for serum glucose even after standing for four hours. The tubes were then refrigerated at 4°C and re-analyzed after another six hours and then once per day for the next four days. Beginning at the first day at the six-hour determination, the glucose levels in the red- and grey-top tubes were statistically indistinguishable from one another but not in the red- and green-top tubes and in the grey- and green-top tubes. This was due to a steady decrease in the glucose levels in the green-top tubes. The glucose levels in the red- and grey-top tubes from each volunteer remained constant over the five-day period so that the coefficients of variation (CV) were low. In contrast, due to the decrease of glucose levels in the green-top tubes, the CVs for repeated glucose determinations in these tubes were high. Interestingly, a regression analysis of the glucose values for all three sets of paired tubes showed high (> 0.97) correlation coefficients and slopes close to 1. However, a regression analysis of the glucose values in the red- and green-top and grey- and green-top tubes at day five showed Y-intercepts of about -32 suggesting that there is a constant decrease of glucose in the green-top tubes that amounts to approximately 6 mg/dL per day over five days. These results suggest that red-top tubes with serum separator or grey-top tubes with a fluoride glycolysis inhibitor may be used for reproducible glucose determinations.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23884222

Source DB:  PubMed          Journal:  Ann Clin Lab Sci        ISSN: 0091-7370            Impact factor:   1.256


  7 in total

1.  Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer.

Authors:  Jia Qin; Huiying Wang; Anton Rets; Saul Harari; Herol Alexis; Ikram Eid; Matthew R Pincus
Journal:  J Clin Lab Anal       Date:  2013-11       Impact factor: 2.352

2.  Are tubes containing sodium fluoride still needed for the measurement of blood glucose in hospital laboratory practice?

Authors:  Amira Al-Kharusi; Nuha Al-Lawati; Manal Al-Kindi; Waad-Allah Mula-Abed
Journal:  Oman Med J       Date:  2014-11

3.  Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

Authors:  Aaron Harper; Chuanyong Lu; Yi Sun; Rafael Garcia; Anton Rets; Herol Alexis; Heba Saad; Ikram Eid; Loretta Harris; Barbara Marshall; Edlira Tafani; Matthew R Pincus
Journal:  J Clin Lab Anal       Date:  2015-04-13       Impact factor: 2.352

4.  Do Serum Creatinine Levels Show Clinically Significant Fluctuations on Serial Determinations on the Siemens Advia 1800 Analyzer?

Authors:  Daniel Levitan; Aaron E Harper; Yi Sun; Jose V Scarpa Carniello; Amir Momeni; Joshua Kagan; Herol Alexis; Ikram Eid; Loretta Harris; Barbara Marshal; Edlira Tafani; Matthew Pincus
Journal:  J Clin Lab Anal       Date:  2016-07-01       Impact factor: 2.352

5.  Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.

Authors:  Marija Kocijancic; Jelena Cargonja; Alma Delic-Knezevic
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

Review 6.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

7.  The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.

Authors:  Fatma Demet Arslan; Inanc Karakoyun; Banu Isbilen Basok; Merve Zeytinli Aksit; Anil Baysoy; Yasemin Kilic Ozturk; Yusuf Adnan Guclu; Can Duman
Journal:  Biochem Med (Zagreb)       Date:  2017-08-28       Impact factor: 2.313

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.