| Literature DB >> 23841095 |
Gustavo Fabián Molina1, Ricardo Juan Cabral, Ignacio Mazzola, Laura Brain Lascano, Jo E Frencken.
Abstract
Adding heat to glass ionomers during setting might improve mechanical properties. The aim was to compare the biaxial flexural strength (BFS) between and within four glass ionomers, by time of exposure to a high-intensity LED light-curing unit. Materials and methods. Samples of Fuji 9 Gold Label, Ketac Molar Easymix, ChemFil Rock, and the EQUIA system were divided into three treatment groups (n = 30): without heating (Group 1), heated with LED lamp of 1400 mW/cm(2) for 30 s while setting (Group 2), and heated with LED lamp of 1400 mW/cm(2) for 60 s while setting (Group 3). Samples were stored for 48 hours in distilled water at 37°C until tested. BFS was tested, using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed, using ANOVA test with the Bonferroni correction (α = 0.05). Heating the glass-ionomer cements with an LED curing light of 1400 mW/cm(2) during setting for 30 s increased the BFS value of all GICs. No statistically significant difference in mean BFS scores was found between the EQUIA system and ChemFil Rock at 30 s and 60 s. The mean BFS value was statistically significantly higher for the EQUIA system and ChemFil Rock than for Fuji 9 Gold Label and Ketac Molar Easymix at all exposure times.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23841095 PMCID: PMC3694373 DOI: 10.1155/2013/838460
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Mean and standard error (SE) of the output temperature in °C for the three curing lights, by time.
| Lamp | Time (sec) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 10 | 20 | 30 | 40 | 50 | 60 | |||||||
| Mean | SE | Mean | SE | Mean | SE | Mean | SE | Mean | SE | Mean | SE | |
| ECCO | 35.0a | 0.6 | 39.8d | 0.9 | 41.0g | 1.0 | 42.8j | 1.8 | 42.5m | 2.6 | 42.0o | 2.9 |
| GCP | 41.3b | 1.1 | 48.0e | 0.8 | 53.3h | 0.6 | 54.0k | 1.2 | 56.0n | 1.6 | 57.3p | 2.4 |
| GSK | 32.0c | 0.0 | 34.5f | 0.3 | 34.5i | 0.7 | 36.3l | 0.5 | 37.0m | 0.6 | 35.0o | 0.4 |
The number of samples is 12 per exposure time. Different superscript letters show significant statistical differences (the Bonferroni test) between the materials.
Product name, manufacturer, composition, batch number, expiration date, and shade of the glass ionomers tested.
| Product name | Manufacturer | Components | Batch no. | Expiry date | Shade |
|---|---|---|---|---|---|
| Fuji 9 Gold Label | GC Europe (Leuven, Belgium) | Powder: fluoroaluminosilicate glass, polyacrylic acid powder | N219047 | 2013/11 | A3 |
| Ketac Molar Easymix | 3M ESPE (Seefeld, Germany) | Powder: Al-Ca-La fluorosilicate glass, 5% copolymer acid (acrylic and maleic acids) | 406641 | 2016/06 | A3 |
| ChemFil Rock | Dentsply DeTrey GmbH (Konstanz, Germany) | Zinc-modified fluoroaluminosilicate glass | 103000542 | 2014/02 | A3 |
| EQUIA system | GC Asia (Tokyo, Japan) | Fuji 9 GP Extra: water, fluoroaluminosilicate glass, polybasic carboxylic acid, polyacrylic acid | 0903039 | 2012/11 | A3 |
The mean biaxial flexural strength (BFS) values expressed in MPa and standard error (SE) of the glass ionomers tested, by test group.
| Glass ionomer | Group 1 (SC) | Group 2 (HC30) | Group 3 (HC60) | |||
|---|---|---|---|---|---|---|
| Mean | SE | Mean | SE | Mean | SE | |
| Chemfil Rock | 61.4d | 1.1 | 73.1e | 1.2 | 75.5e | 1.3 |
| EQUIA system | 67.9d | 1.1 | 73.1e | 1.3 | 78.1f | 1.1 |
| Fuji 9 Gold Label | 43.4a | 0.6 | 52.1b | 1.2 | 54.5b | 1.1 |
| Ketac Molar Easymix | 39.6a | 0.6 | 51.7b | 1.1 | 55.2c | 1.1 |
SC: autocure; HC30: light cured for 30 seconds; and HC60: light cured for 60 seconds.
The number of samples is 30 per glass-ionomer group. Different superscript letters show significant statistical differences (the Bonferroni test) within the materials.