Literature DB >> 27262457

The effect of resin coating on the shear punch strength of restorative glass ionomer cements.

Raphael Pilo1, Ariel Ben-Amar2, Anna Barnea3, Yaron Blasbalg3, Shifra Levartovsky2.   

Abstract

OBJECTIVE: The aim of the current study was to examine the shear punch strength (SPS) of high-strength glass ionomer cements (HSGICs) in relation to coating applications and duration of coating.
MATERIALS AND METHODS: I-Ninety specimens each of Fuji IX GP Fast (FIX Fast), Ionofil Molar AC (IM), Riva Self Cure (R) and Ketac Molar (KM) were prepared and divided into uncoated and coated groups, sub-divided into three sub-groups and incubated for 24 h, 1 week or 8 weeks (distilled water, 37 °C) before SPS. II-Ninety specimens each of uncoated and coated Fuji IX GP Extra were similarly prepared, divided into six sub-groups and incubated for 2 h, 24 h, 1 week, 1 month, 2 months or 3 months (artificial saliva, 37 °C) before SPS. Another 90 specimens were coated for 2 h, 24 h, 1 week, 1 month or 2 months, after which the coating was removed. Specimens were re-incubated in artificial saliva until the end of the 3-month period and then subjected to SPS.
RESULTS: None of the materials gained extra strength when coated. Uncoated KM, IM (at all times) and FIX Fast (at 24 h) were stronger. Fuji IX GP Extra achieved 11.5 MPa after 2 h, which increased to 56.7 MPa after 24 h. The highest strength after 3 months was achieved when the coating was retained for 2 h (71.7 MPa).
CONCLUSION: A resin coating will not positively affect the SPS of HSGICs. CLINICAL RELEVANCE: There is no need to protect HSGICs from water to gain extra strength unless the coating is retained for 2 h.

Entities:  

Keywords:  Artificial saliva; Auto-cured glass ionomer; Distilled water; Resin coating; Shear punch strength

Mesh:

Substances:

Year:  2016        PMID: 27262457     DOI: 10.1007/s00784-016-1862-8

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  35 in total

1.  The influence of resin coating on the shear punch strength of a high strength auto-cure glass ionomer.

Authors:  Jakob Leirskar; Håkon Nordbø; Graham J Mount; Hien Ngo
Journal:  Dent Mater       Date:  2003-03       Impact factor: 5.304

2.  An in vitro study on the maturation of conventional glass ionomer cements and their interface to dentin.

Authors:  Julius Zoergiebel; Nicoleta Ilie
Journal:  Acta Biomater       Date:  2013-08-13       Impact factor: 8.947

3.  Physico-mechanical properties of a fast-set highly viscous GIC restorative.

Authors:  A U J Yap; Y S Pek; P Cheang
Journal:  J Oral Rehabil       Date:  2003-01       Impact factor: 3.837

4.  Strength and wear resistance of a dental glass-ionomer cement with a novel nanofilled resin coating.

Authors:  Ulrich Lohbauer; Norbert Krämer; Gustavo Siedschlag; Edward W Schubert; Brigitte Lauerer; Frank A Müller; Anselm Petschelt; Johannes Ebert
Journal:  Am J Dent       Date:  2011-04       Impact factor: 1.522

5.  The strength of auto-cured and light-cured materials. The shear punch test.

Authors:  G J Mount; O F Makinson; M C Peters
Journal:  Aust Dent J       Date:  1996-04       Impact factor: 2.291

6.  Effect of surface coatings on flexural properties of glass ionomers.

Authors:  M Miyazaki; B K Moore; H Onose
Journal:  Eur J Oral Sci       Date:  1996 Oct-Dec       Impact factor: 2.612

7.  Punch-shear test for dental purposes.

Authors:  R H Roydhouse
Journal:  J Dent Res       Date:  1970 Jan-Feb       Impact factor: 6.116

8.  Mechanical behavior of glass ionomer cements affected by long-term storage in water.

Authors:  M A Cattani-Lorente; C Godin; J M Meyer
Journal:  Dent Mater       Date:  1994-01       Impact factor: 5.304

9.  Surface hardness change of restorative filling materials stored in saliva.

Authors:  K Okada; S Tosaki; K Hirota; W R Hume
Journal:  Dent Mater       Date:  2001-01       Impact factor: 5.304

10.  Effect of G-Coat Plus on the mechanical properties of glass-ionomer cements.

Authors:  R Bagheri; N A Taha; M R Azar; M F Burrow
Journal:  Aust Dent J       Date:  2013-12       Impact factor: 2.291

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.