Literature DB >> 23174652

Effect of gloss and heat on the mechanical behaviour of a glass carbomer cement.

Ulrike Menne-Happ1, Nicoleta Ilie.   

Abstract

OBJECTIVES: The effect of gloss and heat on the mechanical behaviour of a recently launched glass carbomer cement (GCP, GCP dental) was evaluated and compared with resin-modified glass ionomer cements (Fuji II LC, GC and Photac Fil Quick Aplicap, 3M ESPE).
METHODS: 120bar-shaped specimens (n=20) were produced, maintained in distilled water at 37°C and tested after one week. The GCP specimens were cured with and without heat application and with and without gloss. The flexural strength and modulus of elasticity in flexural test as well as the micro-mechanical properties (Vickers Hardness, indentation modulus, creep) of the top and bottom surface were evaluated. The amount and size of the fillers, voids and cracks were compared using a light and a scanning electron microscope.
RESULTS: In the flexural test, the resin-modified glass ionomer cements performed significantly better than GCP. Fuji II LC and Photac Fil (Weibull parameter: 17.7 and 14.3) proved superior reliability in the flexural test compared to GCP (1.4-2.6). The highest Vickers Hardness and lowest creep were achieved by GCP, whereas Fuji II LC reached the highest indentation modulus. The results of this study proved that relationships exist between the compositions, microstructures and mechanical properties of the cements.
CONCLUSIONS: Heat treatment and gloss application did not influence the mechanical properties of GCP. The mechanical properties were basically influenced by the type of cement and its microstructure. CLINICAL SIGNIFICANCE: Considering the measured mechanical properties, there is no need of using gloss or heat when restoring teeth with GCP.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23174652     DOI: 10.1016/j.jdent.2012.11.005

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  10 in total

1.  In-vitro Study on Temperature Changes in the Pulp Chamber Due to Thermo-Cure Glass Ionomer Cements.

Authors:  Raimond Nb van Duinen; Saroash Shahid; Robert Hill; Domagoj Glavina
Journal:  Acta Stomatol Croat       Date:  2016-12

2.  In vitro evaluation of different dental materials used for the treatment of extensive cervical root defects using human periodontal cells.

Authors:  Annemarie Michel; Ralf Erber; Cornelia Frese; Holger Gehrig; Daniel Saure; Johannes Mente
Journal:  Clin Oral Investig       Date:  2016-05-14       Impact factor: 3.573

3.  Flexural Strength of Glass Carbomer Cement and Conventional Glass Ionomer Cement Stored in Different Storage Media over Time.

Authors:  Muhammad Ali Faridi; Abdul Khabeer; Saad Haroon
Journal:  Med Princ Pract       Date:  2018-05-03       Impact factor: 1.927

4.  Intrapulpal Thermal Changes during Setting Reaction of Glass Carbomer® Using Thermocure Lamp.

Authors:  Firdevs Kahvecioglu; Gül Tosun; Hayriye Esra Ülker
Journal:  Biomed Res Int       Date:  2016-12-20       Impact factor: 3.411

5.  Microhardness of glass carbomer and high-viscous glass Ionomer cement in different thickness and thermo-light curing durations after thermocycling aging.

Authors:  Mehmet Buldur; Emine Sirin Karaarslan
Journal:  BMC Oral Health       Date:  2019-12-04       Impact factor: 2.757

6.  Effects of surface coating on the flexural strength of fluoridereleasing restorative materials after water aging for one year.

Authors:  Muhittin Ugurlu
Journal:  Eur Oral Res       Date:  2020-05-01

7.  Temperature increases in primary teeth pulp chamber during polymerization of glass ionomer-based restorative materials.

Authors:  Cigdem Buyukkok; Arife Kaptan
Journal:  Eur Oral Res       Date:  2021-01-04

8.  Retention Ability of a Glass Carbomer Pit and Fissure Sealant.

Authors:  Liana Beresescu; Monika Kovacs; Alexandru Vlasa; Alexandra Mihaela Stoica; Csilla Benedek; Mihai Pop; Denisa Bungardean; Daniela Eșian
Journal:  Int J Environ Res Public Health       Date:  2022-02-10       Impact factor: 3.390

9.  Comparative Evaluation of Compressive Strength and Flexural Strength of GC Gold Hybrid, GIC Conventional and Resin-modified Glass-ionomer Cement.

Authors:  Shantun Malhotra; Kanwalpreet K Bhullar; Sumandeep Kaur; Mahima Malhotra; Rupam Kaur; Aashish Handa
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

10.  Biaxial flexural strength of high-viscosity glass-ionomer cements heat-cured with an LED lamp during setting.

Authors:  Gustavo Fabián Molina; Ricardo Juan Cabral; Ignacio Mazzola; Laura Brain Lascano; Jo E Frencken
Journal:  Biomed Res Int       Date:  2013-06-12       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.