Literature DB >> 12071632

Mechanical properties and bond strength of glass-ionomer cements.

Lúcia Coelho Pereira1, Margareth Calvo Pessutti Nunes, Regina Guenka Palma Dibb, John M Powers, Jean-François Roulet, Maria Fidela de Lima Navarro.   

Abstract

PURPOSE: The objective of this study was to evaluate the mechanical properties and bond strength of glass-ionomer cements (GICs) and resin-modified GICs (RM-GICs) that are indicated as restorative materials for the Atraumatic Restorative Treatment (ART) technique.
MATERIALS AND METHODS: Fifteen disk specimens for the diametral tensile strength (DTS) test and fifteen cylindrical specimens for the compressive strength (CS) test were made of each GIC: Ketac-Fil, Ketac-Molar (ESPE), Fuji IX and Fuji PLUS (GC). Forty human molars were sectioned and embedded in resin with either buccal or lingual surfaces exposed for the tensile bond strength (TBS) test. The surface was ground until a flattened area of enamel or dentin was obtained. After conditioning, inverted truncated cones of GICs were prepared on the flat tooth surfaces. The powder:liquid ratio of Fuji PLUS was adjusted for restorative purposes. Prior to testing, specimens were stored for 24 h (TBS test) and for 1 h, 24 h, and 7 days (CS and DTS tests) in deionized water at 37 degrees C. They were then loaded at a crosshead speed of 1.0 mm/min for CS and 0.5 mm/min for DTS and TBS tests until failure occurred. The data were submitted to two-way ANOVA at 0.05 level of significance, followed by a Tukey-Kramer test for multiple comparisons.
RESULTS: The mean CS values ranged from 90.27 to 170.73 MPa and DTS means from 6.21 to 22.32, with test periods from 1 h to 7 days. The means for TBS ranged from 4.90 to 11.36 MPa and from 2.52 to 5.55 MPa in enamel and dentin, respectively. No differences were found between materials with the CS test except at 1 hour. The resin-modified GIC (RM-GIC) had the highest DTS, with no changes between the test periods, and the highest TBS for both enamel and dentin.
CONCLUSION: Among the GICs tested, RM-GIC showed higher values of DTS and TBS.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12071632

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  16 in total

1.  Influence of different conditioning methods on the shear bond strength of novel light-curing nano-ionomer restorative to enamel and dentin.

Authors:  Yonca Korkmaz; Emre Ozel; Nuray Attar; Ceren Ozge Bicer
Journal:  Lasers Med Sci       Date:  2009-08-18       Impact factor: 3.161

2.  Microleakage of Er:YAG laser and dental bur prepared cavities in primary teeth restored with different adhesive restorative materials.

Authors:  Ali Baghalian; Yahya B Nakhjavani; Tabassom Hooshmand; Pouria Motahhary; Hoda Bahramian
Journal:  Lasers Med Sci       Date:  2012-11-08       Impact factor: 3.161

3.  Bond strength of a new universal self-adhesive resin luting cement to dentin and enamel.

Authors:  Sahar E Abo-Hamar; Karl-Anton Hiller; Heike Jung; Marianne Federlin; Karl-Heinz Friedl; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2005-04-27       Impact factor: 3.573

4.  The effect of bacterial cellulose nanocrystals on the shear bond strength of resin modified glass ionomer cement to dentin.

Authors:  Marzieh Moradian; Dana Jafarpour; Maryam Saadat; Farzin Tahmasebi
Journal:  J Clin Exp Dent       Date:  2021-08-01

5.  Influence of photoactivation source on restorative materials and enamel demineralization.

Authors:  Josiane Marques de Sena Popoff; José Augusto Rodrigues; Wanessa Maria De Freitas Aras; Alessandra Cassoni
Journal:  Photomed Laser Surg       Date:  2014-04-07       Impact factor: 2.796

6.  Evaluation of surface roughness and hardness of different glass ionomer cements.

Authors:  Oya Bala; Hacer Deniz Arisu; Ihsan Yikilgan; Seda Arslan; Abdulkadir Gullu
Journal:  Eur J Dent       Date:  2012-01

7.  Bonding of contemporary glass ionomer cements to different tooth substrates; microshear bond strength and scanning electron microscope study.

Authors:  Aliaa Mohamed El Wakeel; Dina Wafik Elkassas; Mai Mahmoud Yousry
Journal:  Eur J Dent       Date:  2015 Apr-Jun

8.  Fixed lingual orthodontic retainer with bilateral missing lateral incisors produced in PEEK material using CAD/CAM technology.

Authors:  Khaled Aboulazm; Constantin von See; Ahmed Othman
Journal:  J Clin Exp Dent       Date:  2021-06-01

9.  Biaxial flexural strength of high-viscosity glass-ionomer cements heat-cured with an LED lamp during setting.

Authors:  Gustavo Fabián Molina; Ricardo Juan Cabral; Ignacio Mazzola; Laura Brain Lascano; Jo E Frencken
Journal:  Biomed Res Int       Date:  2013-06-12       Impact factor: 3.411

10.  Mechanical, antibacterial and bond strength properties of nano-titanium-enriched glass ionomer cement.

Authors:  Rene Garcia-Contreras; Rogelio Jose Scougall-Vilchis; Rosalía Contreras-Bulnes; Hiroshi Sakagami; Raul Alberto Morales-Luckie; Hiroshi Nakajima
Journal:  J Appl Oral Sci       Date:  2015 May-Jun       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.