Literature DB >> 23837121

Prosthetic mitral valve leaflet escape.

Darae Kim1, Sin Sang Hun, In-Jeong Cho, Chi-Young Shim, Jong-Won Ha, Namsik Chung, Hyun Chul Ju, Jang Won Sohn, Geu-Ru Hong.   

Abstract

Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well.

Entities:  

Keywords:  Cardiac valve prosthesis; Cardiogenic shock; Prosthesis failure

Year:  2013        PMID: 23837121      PMCID: PMC3701786          DOI: 10.4250/jcu.2013.21.2.96

Source DB:  PubMed          Journal:  J Cardiovasc Ultrasound        ISSN: 1975-4612


  11 in total

1.  Fracture-embolization of duromedics valve prosthesis and microscopic uncommon lesions.

Authors:  E Tatou; M Saleh; C Eicher; R Brenot; M David
Journal:  Ann Thorac Surg       Date:  2001-04       Impact factor: 4.330

2.  Mechanical heart valve cavitation: valve specific parameters.

Authors:  M J Eichler; H M Reul
Journal:  Int J Artif Organs       Date:  2004-10       Impact factor: 1.595

3.  Leaflet embolisation from Duromedics valves: a report of two cases.

Authors:  N Kumar; S Balasundaram; M Rickard; Z al Halees; C M Duran
Journal:  Thorac Cardiovasc Surg       Date:  1991-12       Impact factor: 1.827

4.  Leaflet escape from a Duromedics valve.

Authors:  J Alvarez; C W Deal
Journal:  J Thorac Cardiovasc Surg       Date:  1990-02       Impact factor: 5.209

5.  Leaflet escape of a mitral Duromedics prosthesis. Case report.

Authors:  F E Deuvaert; J Devriendt; J Massaut; G Van Nooten; J De Paepe; G Primo
Journal:  Acta Chir Belg       Date:  1989 Jan-Feb       Impact factor: 1.090

6.  Leaflet fracture in Edwards-Duromedics bileaflet valves.

Authors:  W Klepetko; A Moritz; J Mlczoch; H Schurawitzki; E Domanig; E Wolner
Journal:  J Thorac Cardiovasc Surg       Date:  1989-01       Impact factor: 5.209

7.  Leaflet escape in a new bileaflet mechanical valve: TRI technologies.

Authors:  Tomaso Bottio; Dino Casarotto; Gaetano Thiene; Luca Caprili; Annalisa Angelini; Gino Gerosa
Journal:  Circulation       Date:  2003-05-05       Impact factor: 29.690

8.  A 8-year follow-up of the Edwards-Duromedics bileaflet prosthesis.

Authors:  E Baudet; X Roques; J McBride; F Panès; J P Grimaud
Journal:  J Cardiovasc Surg (Torino)       Date:  1995-10       Impact factor: 1.888

9.  Long-term event-free survival with an embolised prosthetic valve leaflet in the thoracic aorta.

Authors:  Mohan P Devbhandari; Edwin B C Woo; Timothy L Hooper
Journal:  J Cardiothorac Surg       Date:  2008-05-30       Impact factor: 1.637

10.  Cineradiography for determination of normal and abnormal function in mechanical heart valves.

Authors:  W Vogel; H P Stoll; W Bay; G Fröhlig; H Schieffer
Journal:  Am J Cardiol       Date:  1993-01-15       Impact factor: 2.778

View more
  2 in total

1.  Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

Authors:  Gaku Uchino; Hideo Yoshida; Naoya Sakoda; Shigeru Hattori; Takuya Kawabata; Munehiro Saiki; Yasufumi Fujita; Keiji Yunoki; Kunikazu Hisamochi; Yoshinari Mine
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-06-03

2.  Spontaneous leaflet fracture resulting in embolization from mechanical valve prostheses.

Authors:  Gijs G J van Steenbergen; Queeny H Y Tsang; Stefan M van der Heide; Michel W A Verkroost; Wilson W L Li; Wim J Morshuis
Journal:  J Card Surg       Date:  2018-12-30       Impact factor: 1.620

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.