Literature DB >> 24789774

Detection of large ions in time-of-flight mass spectrometry: effects of ion mass and acceleration voltage on microchannel plate detector response.

Ranran Liu1, Qiyao Li, Lloyd M Smith.   

Abstract

In time-of-flight mass spectrometry (TOF-MS), ion detection is typically accomplished by the generation and amplification of secondary electrons produced by ions colliding with a microchannel plate (MCP) detector. Here, the response of an MCP detector as a function of ion mass and acceleration voltage is characterized, for singly charged peptide/protein ions ranging from 1 to 290 kDa in mass, and for acceleration voltages from 5 to 25 kV. A nondestructive inductive charge detector (ICD) employed in parallel with MCP detection provides a reliable reference signal to allow accurate calibration of the MCP response. MCP detection efficiencies were very close to unity for smaller ions at high acceleration voltages (e.g., angiotensin, 1046.5 Da, at 25 kV acceleration voltage), but decreased to ~11% for the largest ions examined (immunoglobulin G (IgG) dimer, 290 kDa) even at the highest acceleration voltage employed (25 kV). The secondary electron yield γ (average number of electrons produced per ion collision) is found to be proportional to mv(3.1) (m: ion mass, v: ion velocity) over the entire mass range examined, and inversely proportional to the square root of m in TOF-MS analysis. The results indicate that although MCP detectors indeed offer superlative performance in the detection of smaller peptide/protein species, their performance does fall off substantially for larger proteins, particularly under conditions of low acceleration voltage.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24789774      PMCID: PMC4108536          DOI: 10.1007/s13361-014-0903-2

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  14 in total

1.  Using a superconducting tunnel junction detector to measure the secondary electron emission efficiency for a microchannel plate detector bombarded by large molecular ions

Authors: 
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

2.  Mass spectrometric analysis of DNA mixtures: instrumental effects responsible for decreased sensitivity with increasing mass.

Authors:  Xiaoyu Chen; Michael S Westphall; Lloyd M Smith
Journal:  Anal Chem       Date:  2003-11-01       Impact factor: 6.986

3.  Analysis of megadalton ions using cryodetection MALDI time-of-flight mass spectrometry.

Authors:  Ryan J Wenzel; Urs Matter; Lothar Schultheis; Renato Zenobi
Journal:  Anal Chem       Date:  2005-07-15       Impact factor: 6.986

4.  Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.

Authors:  F Hillenkamp; M Karas; R C Beavis; B T Chait
Journal:  Anal Chem       Date:  1991-12-15       Impact factor: 6.986

5.  Mass discrimination in high-mass MALDI-MS.

Authors:  Simon Weidmann; Gediminas Mikutis; Konstantin Barylyuk; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2013-07-09       Impact factor: 3.109

6.  Impact energy measurement in time-of-flight mass spectrometry with cryogenic microcalorimeters.

Authors:  G C Hilton; J M Martinis; D A Wollman; K D Irwin; L L Dulcie; D Gerber; P M Gillevet; D Twerenbold
Journal:  Nature       Date:  1998-02-12       Impact factor: 49.962

7.  Molecular weight determination of megadalton DNA electrospray ions using charge detection time-of-flight mass spectrometry.

Authors:  S D Fuerstenau; W H Benner
Journal:  Rapid Commun Mass Spectrom       Date:  1995       Impact factor: 2.419

8.  Proteoform: a single term describing protein complexity.

Authors:  Lloyd M Smith; Neil L Kelleher
Journal:  Nat Methods       Date:  2013-03       Impact factor: 28.547

9.  Robust analysis of the yeast proteome under 50 kDa by molecular-mass-based fractionation and top-down mass spectrometry.

Authors:  John F Kellie; Adam D Catherman; Kenneth R Durbin; John C Tran; Jeremiah D Tipton; Jeremy L Norris; Charles E Witkowski; Paul M Thomas; Neil L Kelleher
Journal:  Anal Chem       Date:  2011-12-14       Impact factor: 6.986

10.  High resolution time-of-flight mass analysis of the entire range of intact singly-charged proteins.

Authors:  Jeonghoon Lee; Huijuan Chen; Tiancheng Liu; Clifford E Berkman; Peter T A Reilly
Journal:  Anal Chem       Date:  2011-11-17       Impact factor: 6.986

View more
  5 in total

1.  High Mass Ion Detection with Charge Detector Coupled to Rectilinear Ion Trap Mass Spectrometer.

Authors:  Avinash A Patil; Szu-Wei Chou; Pei-Yu Chang; Chen-Wei Lee; Chun-Yen Cheng; Ming-Lee Chu; Wen-Ping Peng
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-13       Impact factor: 3.109

2.  Simplifying MS1 and MS2 spectra to achieve lower mass error, more dynamic range, and higher peptide identification confidence on the Bruker timsTOF Pro.

Authors:  Daryl Wilding-McBride; Laura F Dagley; Sukhdeep K Spall; Giuseppe Infusini; Andrew I Webb
Journal:  PLoS One       Date:  2022-07-07       Impact factor: 3.752

3.  Stable Picodisc Assemblies from Saposin Proteins and Branched Detergents.

Authors:  Kathleen W Kurgan; Bifan Chen; Kyle A Brown; Paulo Falco Cobra; Xinyu Ye; Ying Ge; Samuel H Gellman
Journal:  Biochemistry       Date:  2021-03-23       Impact factor: 3.162

4.  Characterization of microchannel plate detector response for the detection of native multiply charged high mass single ions in orthogonal-time-of-flight mass spectrometry using a Timepix detector.

Authors:  Anjusha Mathew; Gert B Eijkel; Ian G M Anthony; Shane R Ellis; Ron M A Heeren
Journal:  J Mass Spectrom       Date:  2022-03-10       Impact factor: 2.394

5.  About the mechanism of ultrasonically induced protein capsule formation.

Authors:  Ulrike Doering; Dmitry Grigoriev; Kosti Tapio; Sophia Rosencrantz; Ruben R Rosencrantz; Ilko Bald; Alexander Böker
Journal:  RSC Adv       Date:  2021-04-30       Impact factor: 4.036

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.