Literature DB >> 24683015

High-mass MALDI-MS using ion conversion dynode detectors: influence of the conversion voltage on sensitivity and spectral quality.

Simon Weidmann1, Renato Zenobi.   

Abstract

With the development of special ion conversion dynode (ICD) detectors for high-mass matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), the mass-to-charge ratio is no longer a limiting factor. Although these detectors have been successfully used in the past, there is lack of understanding of the basic processes in the detector. We present a systematic study to investigate the performance of such an ICD detector and separate the contributions of the MALDI process from the ones of the ion-to-secondary ion and the secondary ion-to-electron conversions. The performance was evaluated as a function of the voltages applied to the conversion dynodes and the sample amount utilized, and we found that the detector reflects the MALDI process correctly: limitations such as sensitivity or deviations from the expected signal intensity ratios originate from the MALDI process itself and not from the detector.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24683015     DOI: 10.1007/s13361-014-0867-2

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  15 in total

Review 1.  MALDI-ToF mass spectrometry for studying noncovalent complexes of biomolecules.

Authors:  Stefanie Mädler; Elisabetta Boeri Erba; Renato Zenobi
Journal:  Top Curr Chem       Date:  2013

2.  Analysis of megadalton ions using cryodetection MALDI time-of-flight mass spectrometry.

Authors:  Ryan J Wenzel; Urs Matter; Lothar Schultheis; Renato Zenobi
Journal:  Anal Chem       Date:  2005-07-15       Impact factor: 6.986

Review 3.  Molecular weight determination of peptides and proteins by ESI and MALDI.

Authors:  Kerstin Strupat
Journal:  Methods Enzymol       Date:  2005       Impact factor: 1.600

4.  Immunoassays with direct mass spectrometric detection.

Authors:  Alexis Nazabal; Ryan J Wenzel; Renato Zenobi
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

5.  Characterization of high molecular weight multimeric states of human haptoglobin and hemoglobin-based oxygen carriers by high-mass MALDI MS.

Authors:  Tatiana Pimenova; Claudia P Pereira; Dominik J Schaer; Renato Zenobi
Journal:  J Sep Sci       Date:  2009-04       Impact factor: 3.645

6.  Mass discrimination in high-mass MALDI-MS.

Authors:  Simon Weidmann; Gediminas Mikutis; Konstantin Barylyuk; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2013-07-09       Impact factor: 3.109

Review 7.  Developments in molecular SIMS depth profiling and 3D imaging of biological systems using polyatomic primary ions.

Authors:  John S Fletcher; Nicholas P Lockyer; John C Vickerman
Journal:  Mass Spectrom Rev       Date:  2011 Jan-Feb       Impact factor: 10.946

8.  Epitope mapping on bovine prion protein using chemical cross-linking and mass spectrometry.

Authors:  Tatiana Pimenova; Alexis Nazabal; Bernd Roschitzki; Jan Seebacher; Oliver Rinner; Renato Zenobi
Journal:  J Mass Spectrom       Date:  2008-02       Impact factor: 1.982

9.  MALDI-MS detection of noncovalent interactions of single stranded DNA with Escherichia coli single-stranded DNA-binding protein.

Authors:  Fan Chen; Stefanie Mädler; Simon Weidmann; Renato Zenobi
Journal:  J Mass Spectrom       Date:  2012-05       Impact factor: 1.982

10.  A new, modular mass calibrant for high-mass MALDI-MS.

Authors:  Simon Weidmann; Konstantin Barylyuk; Nadezhda Nespovitaya; Stefanie Mädler; Renato Zenobi
Journal:  Anal Chem       Date:  2013-03-06       Impact factor: 6.986

View more
  1 in total

Review 1.  Insight to Functional Conformation and Noncovalent Interactions of Protein-Protein Assembly Using MALDI Mass Spectrometry.

Authors:  Marco Giampà; Elvira Sgobba
Journal:  Molecules       Date:  2020-10-28       Impact factor: 4.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.