Literature DB >> 23835756

Corneal biomechanics predict the outcome of selective laser trabeculoplasty in medically uncontrolled glaucoma.

Christoph Hirneiß1, K Sekura, U Brandlhuber, A Kampik, M Kernt.   

Abstract

PURPOSE: To evaluate the predictive value of clinical parameters, including biomechanical properties on the outcome of selective laser trabeculoplasty (SLT) in medically uncontrolled open angle glaucoma (OAG).
METHODS: Sixty-eight eyes from 68 patients with OAG and IOP insufficiently regulated by topical medications were enrolled. Patients' follow-up occurred 6 and 12 months after the procedure. The recorded parameters intraocular pressure (IOP), angle characteristics, central corneal thickness (CCT) and biomechanical properties of the eyes, including corneal hysteresis CH and corneal resistance factor CRF measured with the Ocular Responses Analyzer (ORA, Reichert Ophthalmic Instruments) were tested on their predictive value of SLT-induced IOP lowering effect using correlation analyses and regression models.
RESULTS: Mean IOP reduction 12 months after SLT was 4.2 ± 5.7 mmHg (23.2%, from baseline 18.1 ± 5.2 mmHg). The preoperative IOP correlated significantly with IOP reduction (maximum Spearman's correlation r = 0.75, p < 0.001). In linear regression analysis, the corneal biomechanical properties (CH and CRF) together with the baseline IOP revealed good modelling for the IOP lowering effect of SLT (R(2) = 0.64, respectively).
CONCLUSIONS: In addition to the baseline IOP biomechanical properties (CH and CRF) are significant predictors of SLT induced IOP lowering effect in medically uncontrolled OAG.

Entities:  

Mesh:

Year:  2013        PMID: 23835756     DOI: 10.1007/s00417-013-2416-2

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  33 in total

1.  Effect of central corneal thickness on the long-term outcome of selective laser trabeculoplasty as primary treatment for ocular hypertension and primary open-angle glaucoma.

Authors:  Tarek A Shazly; Mark A Latina; John J Dagianis; Satyakant Chitturi
Journal:  Cornea       Date:  2012-08       Impact factor: 2.651

2.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

3.  Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes.

Authors:  Dolores Ortiz; David Piñero; Mohamed H Shabayek; Francisco Arnalich-Montiel; Jorge L Alió
Journal:  J Cataract Refract Surg       Date:  2007-08       Impact factor: 3.351

4.  Lower corneal hysteresis is associated with more rapid glaucomatous visual field progression.

Authors:  Carlos V Gustavo De Moraes; Victoria Hill; Celso Tello; Jeffrey M Liebmann; Robert Ritch
Journal:  J Glaucoma       Date:  2012 Apr-May       Impact factor: 2.503

5.  [Laser puncture of the anterior chamber angle in glaucoma (a preliminary report)].

Authors:  M M Krasnov
Journal:  Vestn Oftalmol       Date:  1972

6.  Corneal hysteresis and corneal resistance factor in keratoectasia: findings using the Reichert ocular response analyzer.

Authors:  Caitriona Kirwan; Donal O'Malley; Michael O'Keefe
Journal:  Ophthalmologica       Date:  2008-07-15       Impact factor: 3.250

7.  Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes.

Authors:  Sunil Shah; Mohammed Laiquzzaman; Rajan Bhojwani; Sanjay Mantry; Ian Cunliffe
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

8.  Ocular Response Analyzer in subjects with and without glaucoma.

Authors:  Michael Sullivan-Mee; Shavon C Billingsley; Amita D Patel; Kathy D Halverson; Brooks R Alldredge; Clifford Qualls
Journal:  Optom Vis Sci       Date:  2008-06       Impact factor: 1.973

9.  Corneal hysteresis measured with the Ocular Response Analyzer in normal and glaucomatous eyes.

Authors:  Olivia Abitbol; Jihène Bouden; Serge Doan; Thanh Hoang-Xuan; Damien Gatinel
Journal:  Acta Ophthalmol       Date:  2009-11-05       Impact factor: 3.761

10.  Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance in glaucoma patients.

Authors:  Anthony P Wells; David F Garway-Heath; Ali Poostchi; Tracey Wong; Kenneth C Y Chan; Nisha Sachdev
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-03-03       Impact factor: 4.799

View more
  8 in total

Review 1.  Selective laser trabeculoplasty: past, present, and future.

Authors:  A Garg; G Gazzard
Journal:  Eye (Lond)       Date:  2018-01-05       Impact factor: 3.775

Review 2.  One Year of Glaucoma Research in Review-2013 to 2014.

Authors:  Sarah H Van Tassel; Nathan M Radcliffe; Anna M Demetriades
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2015 Jul-Aug

Review 3.  Corneal Hysteresis, Intraocular Pressure, and Progression of Glaucoma: Time for a "Hyst-Oric" Change in Clinical Practice?

Authors:  Patrick Murtagh; Colm O'Brien
Journal:  J Clin Med       Date:  2022-05-20       Impact factor: 4.964

4.  The association between corneal hysteresis and surgical outcomes from trabecular meshwork microinvasive glaucoma surgery.

Authors:  Nathaniel Tracer; Samantha Ayoub; Nathan M Radcliffe
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-09-12       Impact factor: 3.117

Review 5.  Corneal hysteresis and its relevance to glaucoma.

Authors:  Madhvi Deol; David A Taylor; Nathan M Radcliffe
Journal:  Curr Opin Ophthalmol       Date:  2015-03       Impact factor: 3.761

6.  The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature.

Authors:  Ryo Asaoka; Shunsuke Nakakura; Hitoshi Tabuchi; Hiroshi Murata; Yoshitaka Nakao; Noriko Ihara; Ulfah Rimayanti; Makoto Aihara; Yoshiaki Kiuchi
Journal:  PLoS One       Date:  2015-10-20       Impact factor: 3.240

7.  The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.

Authors:  Masato Matsuura; Kazunori Hirasawa; Hiroshi Murata; Mieko Yanagisawa; Yoshitaka Nakao; Shunsuke Nakakura; Yoshiaki Kiuchi; Ryo Asaoka
Journal:  PLoS One       Date:  2016-08-31       Impact factor: 3.240

8.  Comparison of Safety and Efficacy Between Ab Interno and Ab Externo Approaches to XEN Gel Stent Placement.

Authors:  Nicholas E Tan; Nathaniel Tracer; Anthony Terraciano; Hardik A Parikh; Joseph F Panarelli; Nathan M Radcliffe
Journal:  Clin Ophthalmol       Date:  2021-01-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.