RandomPOD--a new method and device for advanced wear simulation of orthopaedic biomaterials.

Vesa Saikko1, Jari Kostamo.   

Abstract

A 16-station wear simulator of the pin-on-disc type, called RandomPOD, was designed, built, and validated. The primary area of application of the RandomPOD is wear studies of orthopaedic biomaterials. The type of relative motion between the bearing surfaces, generally illustrated as shapes of slide tracks, has been found to have a strong effect on the type and amount of wear produced. The computer-controlled RandomPOD can be programmed to produce virtually any slide track shape and load profile. In the present study, the focus is on the biomechanically realistic random variation in the track shape and load. In the reference test, the established combination of circular translation and static load was used. In addition, the combinations of random motion/static load, and circular translation/random load were included. The pins were conventional ultra-high molecular weight polyethylene (UHMWPE), the discs were polished CoCr, and the lubricant was diluted calf serum. The UHMWPE wear factor resulting from random motion was significantly higher than that resulting from circular translation. This was probably caused by the fact that in the random motion the direction of sliding changed more than in circular translation with the same sliding distance. The type of load, random vs. static, was unimportant with respect to the wear factor produced. The principal advantage of using the present random track is that possible unrealistic wear phenomena related to the use of fixed track shapes can be avoided.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21288527     DOI: 10.1016/j.jbiomech.2010.12.024

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

Review 1.  Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers.

Authors:  D Baykal; R S Siskey; H Haider; V Saikko; T Ahlroos; S M Kurtz
Journal:  J Mech Behav Biomed Mater       Date:  2013-05-29

2.  Effect of motion inputs on the wear prediction of artificial hip joints.

Authors:  Feng Liu; John Fisher; Zhongmin Jin
Journal:  Tribol Int       Date:  2013-07       Impact factor: 4.872

3.  Effects of Surface Modification and Bulk Geometry on the Biotribological Behavior of Cross-Linked Polyethylene: Wear Testing and Finite Element Analysis.

Authors:  Kenichi Watanabe; Masayuki Kyomoto; Kenichi Saiga; Shuji Taketomi; Hiroshi Inui; Yuho Kadono; Yoshio Takatori; Sakae Tanaka; Kazuhiko Ishihara; Toru Moro
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.