Wear testing of materials and surfaces for total knee replacement.

P S Walker1, G W Blunn, P A Lilley.   

Abstract

A simple wear test was investigated for evaluating the wear and damage of material pairs when used in total knee replacement. The test consisted of an axially loaded metallic femoral indentor and a reciprocating ultrahigh molecular weight polyethylene (UHMWPE) flat disk that represented the tibial component. A number of variables were studied including the effect of conformity by varying the radii of the femoral surface, distilled water or serum as a lubricant, different femoral materials, and different types of UHMWPE. In general, the different morphologies of the surface wear of the UHMWPE were similar to those seen on retrieved total knee replacements. Increased conformity with a cylindrical indentor gave a reduced wear rate initially, compared with that of the lower conformity spherical indentor. However, the wear rates were similar subsequent to this initial wearing in phase. Transfer films of UHMWPE were observed on the cobalt-chrome indentors for both serum and distilled water lubrication, although this film was more extensive for distilled water. The lowest wear rate was observed when oxidized zirconium was used on the femoral side, which was attributed to greater wettability, surface hardness, and immunity to oxidative wear. Tests using cobalt-chrome femoral cylinders and different grades of UHMWPE showed different wear rates. Of these PEs, GUR 415 showed less wear than both RCH 1000 and UHMWPE containing numerous fusion defects. For the latter, wear was attributed to a fatigue mechanism, although in most cases it was associated with surface phenomena rather than subsurface cracking. However, in some specimens of UHMWPE subsurface crack propagations occurred with defects. The test method is discussed in relation to its applicability to the evaluation and comparison of bearing materials and surfaces, with particular application to total knee replacements.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8864888     DOI: 10.1002/(SICI)1097-4636(199623)33:3<159::AID-JBM6>3.0.CO;2-P

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  3 in total

Review 1.  Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers.

Authors:  D Baykal; R S Siskey; H Haider; V Saikko; T Ahlroos; S M Kurtz
Journal:  J Mech Behav Biomed Mater       Date:  2013-05-29

2.  Patients' perspective on controversial issues in total knee arthroplasty.

Authors:  Tae Kyun Kim; Jinbae Choi; Kwang Sook Shin; Chong Bum Chang; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-22       Impact factor: 4.342

3.  Patient and surgery related factors associated with fatigue type polyethylene wear on 49 PCA and DURACON retrievals at autopsy and revision.

Authors:  Markus Rohrbach; Martin Lüem; Peter E Ochsner
Journal:  J Orthop Surg Res       Date:  2008-02-22       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.