Juliana Gonçalves, Telmo Pereira.
Abstract
BACKGROUND: Despite the technological evolution of the implantable defibrillator, one of the questions that remains is the possible benefit of the dual chamber versus single chamber implantable cardioverter defibrillator (ICD) in reducing inappropriate shocks.Entities:
Mesh:
Year: 2013 PMID: 23821405 PMCID: PMC3998159 DOI: 10.5935/abc.20130125
Source DB: PubMed Journal: Arq Bras Cardiol ISSN: 0066-782X Impact factor: 2.000
Selection Sheet for potential articles for the meta-analysis. ICD DR: dual chamber cardioverter defibrillator; ICD VR: single chamber cardioverter defibrillator; ICD: cardioverter defibrillator; CRT-D: cardiac resynchronization therapy and defibrillation; CRT-P: cardiac resynchronization therapy.
| Study reference: __________________ | ||||
| Selection level (check where applicable): | ||||
| Title____ | Abstract____ | Text______ | ||
| Selection Criteria: | ||||
| Do the study patients meet implementation criteria for ICD? Yes/No | ||||
| Are the study patients older than 18 years of age? Yes/No | ||||
| Are the study patients free of chronic atrial fibrillation (AF)? Yes/No | ||||
| Is there a group of patients with ICD DR? Yes/No | ||||
| Is there a group of patients with ICD VR or programmed as VR? Yes/No | ||||
| Were there repeated inappropriate shocks? Yes/No | ||||
| Were there quantified shocks? Yes/No | ||||
| Is it a randomized study? Yes/No | ||||
| Action: (Include only if ALL previous answers have been YES): | ||||
| Included_____ | Excluded_____ | For decision by concensus_____ | ||
Figure 2Systematic Review Flowchart. ICD DR: dual chamber cardioverter defibrillator; ICD VR: single chamber cardioverter defibrillator; ICD: cardioverter defibrillator; CRT-D: cardiac resynchronization therapy and defibrillation; CRT-P: cardiac resynchronization therapy.
Characteristics and design of the studies
| 2008 | 2006 | 2004 | 2001 | |||||||
| Randomized into 3 arms : ICD VR; ICD DR and ICD DR programmed as VR | All DR | All DR | Randomized VR and DR | |||||||
| Parallel with | Parallel | Parallel | Parallel | |||||||
| No concealment | Simple concealment | No concealment | No concealment | |||||||
| All causes of death; invasive interventions; hospitalizations of CV cause; inappropriate shocks; sustained AT > 48 hours | Inappropriate detection of SVT | Inappropriate therapies for atrial arrhythmias | Inappropriate therapies and complications of ICD | |||||||
| 15.7 months | 6 months | 12 months | 7 months | |||||||
| 3334 | 1111 | 111-Stimulate in VR | 400 | 199 | 60 | 29 | 92 | 45 | ||
| 112 | 201 | 31 | 47 | |||||||
ICD VR: single-chamber cardioverter defibrillator; ICD DR: dual-chamber cardioverter defibrillator; VR: single chamber; DR: dual chamber; SVT: supraventricular tachycardia; CV: cardiovascular; AT: atrial tachycardia.
Clinical characteristics of the included studies
| 64 | 65 | 59 | 61 | ||
| 84 | 80 | 78 | 90 | ||
| 85 | 81 | 78 | 67 | ||
| 36 | 32 | 30 | - | ||
| - | 29 | 25 | 11 | ||
| - | 25 | 32 | 17 | ||
| - | 6 | 57 | 93 | ||
| - | - | 17 | - | ||
EJ: Ejection fraction; AT: Atrial Tachycardia.
Distribution of inappropriate shocks in the meta-analysis population, according to the type of device
| 391/886 | 44 | 495/886 | 56 | |
| 38 | 9,7 | 28 | 5,6 | |
ICD DR: dual-chamber cardioverter defibrillator; ICD VR: single-chamber cardioverter defibrillator; n: number of patients with inappropriate shocks; N: total sample.
Figure 3Forest Plot representing the model analysis of fixed effect model in the evaluation of the list of patients carriers of dual chamber cardioverter defibrillator versus single chamble cardioverter defibrillator in the occurrence of inappropriate shocks.
Figure 4Forest Plot representing the model analysis of random effect in the evaluation of the list of patients. ICD DR: dual chamber cardioverter defibrillator; ICD VR: single chamber cardioverter defibrillator.
Study sensitivity analysis
| 1.49 | 0.85-2.61 | 0.04 | 69 | |
| 1.7 | 0.99-2.9 | 0.12 | 52 | |
| 0.7 | 0.28-1.75 | 0.15 | 47 | |
| 1.91 | 1.09-3.37 | 0.27 | 24 |
OR: Odds Ratio; CI: Confidence Interval; X2: chi-square; I2: heterogeneity.