Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides.

Young-Taeg Sul1, Carina B Johansson, Youngsoo Jeong, Ann Wennerberg, Tomas Albrektsson.   

Abstract

The present experimental study was designed to address two issues. The first was to investigate whether oxide properties of titanium implants influenced bone tissue responses after an in vivo implantation time of six weeks. If such a result was found, the second aim was to investigate which oxide properties are involved in such bone tissue responses. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of 200 nm to 1000 nm. The surface morphology was prepared in two substantially different ways, i.e. barrier and porous oxide film structures. The micropore structure revealed pore sizes of 8 microm in diameter, with a range in opening area from 1.27 microm 2 to 2.1 microm 2. Porosity ranged from 12.7% to 24.4%. The crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. The chemical compositions consisted mainly of TiO2. Surface roughness ranged from 0.96 microm to 1.03 microm (Sa). Each group of test samples showed its own, defined status with respect to these various parameters. The oxide properties of turned commercially pure titanium implants were used in the control group, which was characterized by an oxide thickness of 17.4 +/- 6.2 nm, amorphous type in crystallinity, TiO2 in chemical composition, and a surface roughness of 0.83 microm (Sa). Bone tissue responses were evaluated by resonance frequency measurements and removal torque tests that were undertaken six weeks after implant insertion in rabbit tibia. Implants that had an oxide thickness of approximately 600, 800 and 1000 nm demonstrated significantly stronger bone responses in the evaluation of removal torque values than did implants that had an oxide thickness of approximately 17 and 200 nm (P < 0.05). However, there were no difference between implants with oxide thicknesses of 17 and 200 nm (P = 0.99). It was concluded that oxide properties of titanium implants, which include oxide thickness, micropore configurations and crystal structures, greatly influence the bone tissue response in the evaluation of removal torque values. However, it is not fully understood whether these oxide properties influence the bone tissue response separately or synergistically.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12010155     DOI: 10.1034/j.1600-0501.2002.130304.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  21 in total

1.  [Systematic qualitative histology of enossal implants with anodically oxidised surfaces].

Authors:  B Al-Nawas; K A Grötz; H Goetz; M Feil; H Duschner; W Wagner
Journal:  Mund Kiefer Gesichtschir       Date:  2006-07

Review 2.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

Review 3.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

4.  Osseointegration of bioactive microarc oxidized amorphous phase/TiO2 nanocrystals composited coatings on titanium after implantation into rabbit tibia.

Authors:  Rui Zhou; Daqing Wei; Haoyue Yang; Su Cheng; Wei Feng; Baoqiang Li; Yaming Wang; Dechang Jia; Yu Zhou
Journal:  J Mater Sci Mater Med       Date:  2014-01-31       Impact factor: 3.896

5.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

Review 6.  Biomaterial strategies for engineering implants for enhanced osseointegration and bone repair.

Authors:  Rachit Agarwal; Andrés J García
Journal:  Adv Drug Deliv Rev       Date:  2015-04-08       Impact factor: 15.470

7.  Electrochemical growth behavior, surface properties, and enhanced in vivo bone response of TiO2 nanotubes on microstructured surfaces of blasted, screw-shaped titanium implants.

Authors:  Young-Taeg Sul
Journal:  Int J Nanomedicine       Date:  2010-04-15

8.  Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs.

Authors:  Seok Ahn; Mong-Sook Vang; Hong-So Yang; Sang-Won Park; Hyun-Pil Lim
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

9.  Biologic stability of plasma ion-implanted miniscrews.

Authors:  Young-Chae Cho; Jung-Yul Cha; Chung-Ju Hwang; Young-Chel Park; Han-Sung Jung; Hyung-Seog Yu
Journal:  Korean J Orthod       Date:  2013-06-24       Impact factor: 1.372

10.  Effect of surface anodization on stability of orthodontic microimplant.

Authors:  Sanket Karmarker; Wonjae Yu; Hee-Moon Kyung
Journal:  Korean J Orthod       Date:  2012-02-27       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.