Literature DB >> 3858415

The "balanced force" concept for instrumentation of curved canals.

J B Roane, C L Sabala, M G Duncanson.   

Abstract

Mesh:

Year:  1985        PMID: 3858415     DOI: 10.1016/S0099-2399(85)80061-3

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


× No keyword cloud information.
  65 in total

1.  A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals.

Authors:  Young-Sil Yoo; Yong-Bum Cho
Journal:  Restor Dent Endod       Date:  2012-11-21

2.  Evaluation of Single File Systems Reciproc, Oneshape, and WaveOne using Cone Beam Computed Tomography -An In Vitro Study.

Authors:  Annil Dhingra; Nidhi Ruhal; Anjali Miglani
Journal:  J Clin Diagn Res       Date:  2015-04-01

3.  "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

Authors:  N Tulasi Priya; Veeramachaneni Chandrasekhar; S Anita; Muralidhar Tummala; T B Phanindhar Raj; Vijetha Badami; Pradeep Kumar; E Soujanya
Journal:  J Clin Diagn Res       Date:  2014-12-05

4.  Both operator and heat treatment determine the centring ability of Reciproc® files in vitro.

Authors:  N Hofmann
Journal:  Clin Oral Investig       Date:  2018-05-12       Impact factor: 3.573

5.  Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system.

Authors:  Daniely Amorin Meireles; Mariana Mena Barreto Bastos; André Augusto Franco Marques; Lucas da Fonseca Roberti Garcia; Emílio Carlos Sponchiado
Journal:  Restor Dent Endod       Date:  2013-08-23

6.  Minimally invasive endodontics: challenging prevailing paradigms.

Authors:  A H Gluskin; C I Peters; O A Peters
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

Review 7.  Shaping the root canal system.

Authors:  M Waplington; A S McRobert
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

8.  Bacterial colonization in the apical part of extracted human teeth following root-end resection and filling: a confocal laser scanning microscopy study.

Authors:  Igor Tsesis; Shlomo Elbahary; Nuphar Blau Venezia; Eyal Rosen
Journal:  Clin Oral Investig       Date:  2017-03-28       Impact factor: 3.573

9.  Mechanical resistance of carbon and stainless steel hand instruments used in a reciprocating handpiece.

Authors:  Lucila Piasecki; Dina Al-Sudani; Alessio Giansiracusa Rubini; Giampaolo Sannino; Giampaolo Sonnino; Maurizio Bossù; Luca Testarelli; Roberto Di Giorgio; Ulisses Xavier da Silva-Neto; Christian Giampietro Brandão; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

10.  CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study.

Authors:  Shruthi Nagaraja; B V Sreenivasa Murthy
Journal:  J Conserv Dent       Date:  2010-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.