Literature DB >> 23809394

Clinical application and laboratory protocols for performing contrast echocardiography.

Adrian Chong1, Brian Haluska, Sudhir Wahi.   

Abstract

Technically difficult echocardiographic studies with suboptimal images remain a significant challenge in clinical practice despite advances in imaging technologies over the past decades. Use of microbubble ultrasound contrast for left ventricular opacification and enhancement of endocardial border detection during rest or stress echocardiography has become an essential component of the operation of the modern echocardiography laboratory. Contrast echocardiography has been demonstrated to improve diagnostic accuracy and confidence across a range of indications including quantitative assessment of left ventricular systolic function, wall motion analysis, and left ventricular structural abnormalities. Enhancement of Doppler signals and myocardial contrast echocardiography for perfusion remain off-label uses. Implementation of a contrast protocol is feasible for most laboratories and both physicians and sonographers will require training in contrast specific imaging techniques for optimal use. Previous concerns regarding the safety of contrast agents have since been addressed by more recent data supporting its excellent safety profile and overall cost-effectiveness.
Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23809394      PMCID: PMC3861153          DOI: 10.1016/j.ihj.2013.04.002

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  62 in total

Review 1.  Meta-analysis of adverse cardiovascular events associated with echocardiographic contrast agents.

Authors:  Owais A Khawaja; Kamran A Shaikh; Mouaz H Al-Mallah
Journal:  Am J Cardiol       Date:  2010-07-23       Impact factor: 2.778

2.  Cardiotoxicity of chemotherapeutic agents and radiotherapy-related heart disease: ESMO Clinical Practice Guidelines.

Authors:  D Bovelli; G Plataniotis; F Roila
Journal:  Ann Oncol       Date:  2010-05       Impact factor: 32.976

3.  Thinking outside the "box"-the ultrasound contrast controversy.

Authors:  Michael L Main; Jonathan H Goldman; Paul A Grayburn
Journal:  J Am Coll Cardiol       Date:  2007-12-03       Impact factor: 24.094

Review 4.  Contrast echocardiography: evidence-based recommendations by European Association of Echocardiography.

Authors:  Roxy Senior; Harald Becher; Mark Monaghan; Luciano Agati; Jose Zamorano; Jean Louis Vanoverschelde; Petros Nihoyannopoulos
Journal:  Eur J Echocardiogr       Date:  2009-03

5.  The safety of deFinity and Optison for ultrasound image enhancement: a retrospective analysis of 78,383 administered contrast doses.

Authors:  Kevin Wei; Sharon L Mulvagh; Lisa Carson; Ravin Davidoff; Ruvin Gabriel; Richard A Grimm; Stephanie Wilson; Lorrie Fane; Charles A Herzog; William A Zoghbi; Rhonda Taylor; Michael Farrar; Farooq A Chaudhry; Thomas R Porter; Waleed Irani; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2008-10-10       Impact factor: 5.251

6.  Contrast echocardiography: beyond a black box warning?

Authors:  Steven J Lester; Fletcher A Miller; Bijoy K Khandheria
Journal:  J Am Soc Echocardiogr       Date:  2008-05       Impact factor: 5.251

7.  ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography. A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Echocardiography, American Heart Association, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Critical Care Medicine, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance American College of Chest Physicians.

Authors:  Pamela S Douglas; Mario J Garcia; David E Haines; Wyman W Lai; Warren J Manning; Ayan R Patel; Michael H Picard; Donna M Polk; Michael Ragosta; R Parker Ward; Rory B Weiner
Journal:  J Am Soc Echocardiogr       Date:  2011-03       Impact factor: 5.251

8.  American Society of Echocardiography Consensus Statement on the Clinical Applications of Ultrasonic Contrast Agents in Echocardiography.

Authors:  Sharon L Mulvagh; Harry Rakowski; Mani A Vannan; Sahar S Abdelmoneim; Harald Becher; S Michelle Bierig; Peter N Burns; Ramon Castello; Patrick D Coon; Mary E Hagen; James G Jollis; Thomas R Kimball; Dalane W Kitzman; Itzhak Kronzon; Arthur J Labovitz; Roberto M Lang; Joseph Mathew; W Stuart Moir; Sherif F Nagueh; Alan S Pearlman; Julio E Perez; Thomas R Porter; Judy Rosenbloom; G Monet Strachan; Srihari Thanigaraj; Kevin Wei; Anna Woo; Eric H C Yu; William A Zoghbi
Journal:  J Am Soc Echocardiogr       Date:  2008-11       Impact factor: 5.251

9.  Detection of coronary artery disease with perfusion stress echocardiography using a novel ultrasound imaging agent: two Phase 3 international trials in comparison with radionuclide perfusion imaging.

Authors:  Roxy Senior; Mark Monaghan; Michael L Main; Jose L Zamorano; Klaus Tiemann; Luciano Agati; Neil J Weissman; Allan L Klein; Thomas H Marwick; Masood Ahmad; Anthony N DeMaria; Miguel Zabalgoitia; Harald Becher; Sanjiv Kaul; James E Udelson; Frans J Wackers; Richard C Walovitch; Michael H Picard
Journal:  Eur J Echocardiogr       Date:  2009-01

10.  Acute mortality in hospitalized patients undergoing echocardiography with and without an ultrasound contrast agent: results in 18,671 consecutive studies.

Authors:  Lisa L Kusnetzky; Adnan Khalid; Taiyeb M Khumri; Tabitha G Moe; Philip G Jones; Michael L Main
Journal:  J Am Coll Cardiol       Date:  2008-04-09       Impact factor: 24.094

View more
  2 in total

Review 1.  Recent technological advancements in cardiac ultrasound imaging.

Authors:  Jaydev K Dave; Maureen E Mc Donald; Praveen Mehrotra; Andrew R Kohut; John R Eisenbrey; Flemming Forsberg
Journal:  Ultrasonics       Date:  2017-11-23       Impact factor: 2.890

2.  Misdiagnosis or Missed Diagnosis: Digging Out the "Near-Field Clutter" Artifact in a Patient with Stroke.

Authors:  Laurens De Vos; Veerle De Herdt; Frank Timmermans
Journal:  CASE (Phila)       Date:  2019-12-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.