The safety of deFinity and Optison for ultrasound image enhancement: a retrospective analysis of 78,383 administered contrast doses.

Kevin Wei1, Sharon L Mulvagh, Lisa Carson, Ravin Davidoff, Ruvin Gabriel, Richard A Grimm, Stephanie Wilson, Lorrie Fane, Charles A Herzog, William A Zoghbi, Rhonda Taylor, Michael Farrar, Farooq A Chaudhry, Thomas R Porter, Waleed Irani, Roberto M Lang.   

Abstract

BACKGROUND: The purpose of this retrospective analysis was to define the incidence of severe adverse events after exposure to ultrasound contrast agents.
METHODS: Data between January 1, 2001, and September 30, 2007, were collected using invited responses to an on-line web-based questionnaire from 1 general and 12 cardiac ultrasound laboratories. During a period of 4.5 +/- 2.4 years, a total of 66,164 doses of Definity (Lantheus Medical Imaging, North Billerica, MA) and 12,219 doses of Optison (GE Healthcare, Buckinghamshire, UK) were administered, reflecting contrast use in 5% of transthoracic and 28% of stress echocardiographic procedures. More than 10,000 doses were given to critically ill patients in intensive care unit settings or to patients with acute chest pain of suspected cardiac origin. The median age of patients who received an ultrasound contrast agent was 60 years, 49% were male, and the mean body mass index was 32 +/- 1.4 g/m(-2).
RESULTS: Severe reactions that were considered "probably" related to an ultrasound contrast agent developed in 8 patients (0.01%), all of whom were outpatients, and 4 (0.006%) of these were consistent with anaphylactoid reactions. There were no deaths reported. All patients recovered with treatment. No serious events were seen in inpatients.
CONCLUSION: This multicenter, retrospective analysis includes the largest number of doses of ultrasound contrast agents ever published and a large number of patients evaluated in a wide variety of settings, including the critically ill. It shows that these agents have a good safety profile in both cardiac and abdominal ultrasound applications. The incidence of severe adverse reactions to ultrasound contrast agents is no greater, and may be lower, than that reported for contrast agents commonly used in other cardiac imaging tests.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18848430     DOI: 10.1016/j.echo.2008.07.019

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  59 in total

Review 1.  Contrast echocardiography: what have we learned from the new guidelines?

Authors:  Kevin Wei
Journal:  Curr Cardiol Rep       Date:  2010-05       Impact factor: 2.931

2.  Effect of surface architecture on in vivo ultrasound contrast persistence of targeted size-selected microbubbles.

Authors:  Cherry C Chen; Shashank R Sirsi; Shunichi Homma; Mark A Borden
Journal:  Ultrasound Med Biol       Date:  2012-03       Impact factor: 2.998

3.  Quantification of Microvascular Tortuosity during Tumor Evolution Using Acoustic Angiography.

Authors:  Sarah E Shelton; Yueh Z Lee; Mike Lee; Emmanuel Cherin; F Stuart Foster; Stephen R Aylward; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-04-07       Impact factor: 2.998

4.  Design of ultrasonically-activatable nanoparticles using low boiling point perfluorocarbons.

Authors:  Paul S Sheeran; Samantha H Luois; Lee B Mullin; Terry O Matsunaga; Paul A Dayton
Journal:  Biomaterials       Date:  2012-01-29       Impact factor: 12.479

Review 5.  Contrast echocardiography: an update.

Authors:  Rajesh K Chelliah; Roxy Senior
Journal:  Curr Cardiol Rep       Date:  2009-05       Impact factor: 2.931

Review 6.  [Assessment of systolic function in patients with poor echogenicity: echocardiographic methods].

Authors:  F Weidemann; D Liu; M Niemann; S Herrmann; H Hu; P D Gaudron; G Ertl; K Hu
Journal:  Herz       Date:  2013-08-15       Impact factor: 1.443

7.  Clinical application and laboratory protocols for performing contrast echocardiography.

Authors:  Adrian Chong; Brian Haluska; Sudhir Wahi
Journal:  Indian Heart J       Date:  2013-04-06

8.  Ultrasound super-resolution imaging provides a noninvasive assessment of renal microvasculature changes during mouse acute kidney injury.

Authors:  Qiyang Chen; Jaesok Yu; Brittney M Rush; Sean D Stocker; Roderick J Tan; Kang Kim
Journal:  Kidney Int       Date:  2020-03-03       Impact factor: 10.612

9.  A micrometer-sized ultrasound contrast agent with nanometer-scale polygonal patterning surfaces.

Authors:  Zhonghua Teng; Shiping Cao; Wei Li; Li Yang; Wen Shi; Yuegang Wang; Juefei Wu; Jianping Bin
Journal:  J Med Ultrason (2001)       Date:  2014-05-27       Impact factor: 1.314

10.  Ischemic memory imaging in nonhuman primates with echocardiographic molecular imaging of selectin expression.

Authors:  Brian P Davidson; Scott M Chadderdon; J Todd Belcik; Saurabh Gupta; Jonathan R Lindner
Journal:  J Am Soc Echocardiogr       Date:  2014-04-26       Impact factor: 5.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.