A technique is described for accurate measurement of intraarterial pressure through radial artery catheters in neonates. The technique, which can be used for short-term monitoring, uses cannulation of the radial artery with a 24-gauge Teflon catheter, connected by a Luer-Lok fitting to a three-way stopcock and a high-fidelity tip transducer. In vitro studies showed that the system is linear and the frequency response is flat (+/- 3 dB) up to 50 Hz. The technique permits gathering of high-quality pressure data and can be used in the area of neonatal clinical research for short-term monitoring. It needs to be developed further before routine application in clinical practice can be recommended.

Entities:  

Mesh:

Year:  1990        PMID: 2380752     DOI: 10.1007/bf02832149

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  13 in total

1.  Physiologic recording by modern instruments with particular reference to pressure recording.

Authors:  D L FRY
Journal:  Physiol Rev       Date:  1960-10       Impact factor: 37.312

2.  Experience with percutaneous indwelling peripheral arterial catheterization in neonates.

Authors:  S N Randel; B H Tsang; J T Wung; J M Driscoll; L S James
Journal:  Am J Dis Child       Date:  1987-08

3.  The continuous measurement of intra-arterial pressure in the neonate: method and accuracy.

Authors:  D H Evans; G M Lark; L N Archer; M I Levene
Journal:  Clin Phys Physiol Meas       Date:  1986-05

4.  Quantification and simulation of fluid-filled catheter/transducer systems.

Authors:  B C Taylor; D M Ellis; J M Drew
Journal:  Med Instrum       Date:  1986 May-Jun

5.  Damped and undamped frequency responses of underdamped catheter manometer systems.

Authors:  G G Shapiro; L J Krovetz
Journal:  Am Heart J       Date:  1970-08       Impact factor: 4.749

6.  Arterial blood pressure in the very low birthweight neonate. Evaluation of an automatic oscillometric technique.

Authors:  S E Sonesson; U Broberger
Journal:  Acta Paediatr Scand       Date:  1987-03

7.  Direct blood pressure measurement--dynamic response requirements.

Authors:  R M Gardner
Journal:  Anesthesiology       Date:  1981-03       Impact factor: 7.892

8.  Effect of the dynamic response of transducer-tubing system on accuracy of direct blood pressure measurement in patients.

Authors:  A Boutros; S Albert
Journal:  Crit Care Med       Date:  1983-02       Impact factor: 7.598

9.  Use of Fourier series for the analysis of biological systems.

Authors:  E O Attinger; A Anné; D A McDonald
Journal:  Biophys J       Date:  1966-05       Impact factor: 4.033

10.  Radial arterial catheters in children and neonates: a prospective study.

Authors:  H Selldén; K Nilsson; L E Larsson; B Ekström-Jodal
Journal:  Crit Care Med       Date:  1987-12       Impact factor: 7.598

View more
  5 in total

1.  Accuracy of oscillometric blood pressure measurement in critically ill neonates with reference to the arterial pressure wave shape.

Authors:  M Gevers; H R van Genderingen; H N Lafeber; W W Hack
Journal:  Intensive Care Med       Date:  1996-03       Impact factor: 17.440

2.  Calculated mean arterial pressure in the posterior tibial and radial artery pressure wave in newborn infants.

Authors:  M Gevers; M W Hack; H R van Genderingen; H N Lafeber; N Westerhof
Journal:  Basic Res Cardiol       Date:  1995 May-Jun       Impact factor: 17.165

3.  Calculated mean arterial blood pressure in critically ill neonates.

Authors:  M Gevers; W W Hack; E F Ree; H N Lafeber; N Westerhof
Journal:  Basic Res Cardiol       Date:  1993 Jan-Feb       Impact factor: 17.165

4.  Dynamic response of a neonatal catheter-manometer system in situ.

Authors:  H van Langen; P Brienesse; K Kopinga; P Wijn
Journal:  J Clin Monit       Date:  1993-11

5.  Prevention of air introduction in catheter-manometer systems for accurate neonatal blood pressure measurement: an in vitro study.

Authors:  H R van Genderingen; M Gevers; W W Hack
Journal:  J Clin Monit       Date:  1994-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.