Arterial blood pressure in the very low birthweight neonate. Evaluation of an automatic oscillometric technique.

S E Sonesson, U Broberger.   

Abstract

The noninvasive oscillometric technique of arterial blood pressure determination was evaluated in fifteen very low birth weight neonates (less than 1,400 g). Measurement of invasive umbilical artery catheter pressure was used as a reference standard. By using a cuff width to arm circumference ratio of 0.33-0.42, mean blood pressure was overestimated by 6.2 (7.2) mmHg (mean and 1 SD), p less than 0.001. More accurate mean blood pressure measurements were recorded with a cuff width to arm circumference ratio of 0.44-0.55. Measurements of systolic and diastolic blood pressure showed similar results.

Entities:  

Mesh:

Year:  1987        PMID: 3591301     DOI: 10.1111/j.1651-2227.1987.tb10471.x

Source DB:  PubMed          Journal:  Acta Paediatr Scand        ISSN: 0001-656X


  7 in total

1.  Accurate measurement of intraarterial pressure through radial artery catheters in neonates.

Authors:  W W Hack; N Westerhof; T Leenhoven; A Okken
Journal:  J Clin Monit       Date:  1990-07

2.  Left ventricular output during postnatal circulatory adaptation in healthy infants born at full term.

Authors:  P Winberg; M Jansson; L Marions; B P Lundell
Journal:  Arch Dis Child       Date:  1989-10       Impact factor: 3.791

3.  Accuracy of oscillometric blood pressure measurement in critically ill neonates with reference to the arterial pressure wave shape.

Authors:  M Gevers; H R van Genderingen; H N Lafeber; W W Hack
Journal:  Intensive Care Med       Date:  1996-03       Impact factor: 17.440

4.  Blood pressure and blood volume in preterm infants.

Authors:  I M Wright; S R Goodall
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-05       Impact factor: 5.747

Review 5.  Hypertension in infancy: diagnosis, management and outcome.

Authors:  Janis M Dionne; Carolyn L Abitbol; Joseph T Flynn
Journal:  Pediatr Nephrol       Date:  2011-01-22       Impact factor: 3.714

6.  Response to dobutamine and dopamine in the hypotensive very preterm infant.

Authors:  J C Rozé; C Tohier; C Maingueneau; M Lefèvre; A Mouzard
Journal:  Arch Dis Child       Date:  1993-07       Impact factor: 3.791

7.  Discrepancy between invasive and non-invasive blood pressure readings in extremely preterm infants in the first four weeks of life.

Authors:  Tobias Werther; Lukas Aichhorn; Sigrid Baumgartner; Angelika Berger; Katrin Klebermass-Schrehof; Ulrike Salzer-Muhar
Journal:  PLoS One       Date:  2018-12-28       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.