Literature DB >> 3677763

Radial arterial catheters in children and neonates: a prospective study.

H Selldén1, K Nilsson, L E Larsson, B Ekström-Jodal.   

Abstract

Over a 3-yr period (1982 to 1984), 533 arterial catheters were inserted in 476 patients admitted to the pediatric ICU or the operating room. Radial arterial catheterization with small-bore, 0.8-mm, 22-ga Teflon cannulas was the most common method (376 of 533 cannulations), and 296 of these catheters were inserted in patients less than 1 yr of age. All catheters were flushed intermittently with heparin (12.5 U/ml) in isotonic saline. The mean catheter duration was 2.6 days, and only minor complications were noted. The main reason for catheter removal was malfunction of the arterial line. There was no difference in duration or complication rate between catheters inserted percutaneously or by cutdown. Over a 6-month period (1985 to 1986), 42 0.8-mm, 22-ga radial arterial catheters were inserted in 39 patients less than 1 yr of age; all catheters were maintained by a continuous flushing system using heparin (5 U/ml) in isotonic saline. The mean duration was 6.3 days. No complications were noted, and the proportion of catheter malfunction decreased. This study confirms the safety of radial arterial catheterization in children and neonates. The continuous flushing system considerably improved catheter patency compared to a method using intermittent flushing.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3677763     DOI: 10.1097/00003246-198712000-00006

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  3 in total

1.  Antithrombotic therapy in neonates and children: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Paul Monagle; Anthony K C Chan; Neil A Goldenberg; Rebecca N Ichord; Janna M Journeycake; Ulrike Nowak-Göttl; Sara K Vesely
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

2.  Accurate measurement of intraarterial pressure through radial artery catheters in neonates.

Authors:  W W Hack; N Westerhof; T Leenhoven; A Okken
Journal:  J Clin Monit       Date:  1990-07

3.  Incidence and duration of total occlusion of the radial artery in newborn infants after catheter removal.

Authors:  W W Hack; A Vos; J van der Lei; A Okken
Journal:  Eur J Pediatr       Date:  1990-01       Impact factor: 3.183

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.