Literature DB >> 23784967

Improved three-dimensional Look-Locker acquisition scheme and angle map filtering procedure for T1 estimation.

CheukKai Hui1, Emilio Esparza-Coss, Ponnada A Narayana.   

Abstract

The three-dimensional (3D) Look-Locker (LL) acquisition is a widely used fast and efficient T1 mapping method. However, the multi-shot approach of 3D LL acquisition can introduce reconstruction artifacts that result in intensity distortions. Traditional 3D LL acquisition generally utilizes a centric encoding scheme that is limited to a single phase-encoding direction in k space. To optimize k-space segmentation, an elliptical scheme with two phase-encoding directions is implemented for the LL acquisition. This elliptical segmentation can reduce the intensity errors in the reconstructed images and improve the final T1 estimation. One of the major sources of error in LL-based T1 estimation is a lack of accurate knowledge of the actual flip angle. A multi-parameter curve-fitting procedure can account for some of the variability in the flip angle. However, curve fitting can also introduce errors in the estimated flip angle that can result in incorrect T1 values. A filtering procedure based on goodness of fit (GOF) is proposed to reduce the effect of false flip angle estimates. Filtering based on GOF weighting can remove probable incorrect angles that result in bad curve fitting. Simulation, phantom and in vivo studies have demonstrated that these techniques can improve the accuracy of 3D LL T1 estimation.
Copyright © 2013 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Look-Locker T1 mapping; elliptical segmentation; goodness-of-fit weighted filtering

Mesh:

Substances:

Year:  2013        PMID: 23784967      PMCID: PMC3785574          DOI: 10.1002/nbm.2969

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  20 in total

1.  A fast 3D look-locker method for volumetric T1 mapping.

Authors:  E Henderson; G McKinnon; T Y Lee; B K Rutt
Journal:  Magn Reson Imaging       Date:  1999-10       Impact factor: 2.546

2.  Rapid T(1) mapping using multislice echo planar imaging.

Authors:  S Clare; P Jezzard
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

3.  Fast T1 mapping on a whole-body scanner.

Authors:  R Deichmann; D Hahn; A Haase
Journal:  Magn Reson Med       Date:  1999-07       Impact factor: 4.668

4.  An improved 3-D Look--Locker imaging method for T(1) parameter estimation.

Authors:  Ken Nkongchu; Giles Santyr
Journal:  Magn Reson Imaging       Date:  2005-09-08       Impact factor: 2.546

5.  Rapid high-resolution T(1) mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity.

Authors:  Hai-Ling Margaret Cheng; Graham A Wright
Journal:  Magn Reson Med       Date:  2006-03       Impact factor: 4.668

6.  Novel method for rapid, simultaneous T1, T2*, and proton density quantification.

Authors:  J B M Warntjes; O Dahlqvist; P Lundberg
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

7.  Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles.

Authors:  C Preibisch; R Deichmann
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

8.  On the steady-state properties of actual flip angle imaging (AFI).

Authors:  Kay Nehrke
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

9.  Modulated repetition time look-locker (MORTLL): a method for rapid high resolution three-dimensional T1 mapping.

Authors:  Neville D Gai; John A Butman
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

10.  Accurate multislice gradient echo T(1) measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity.

Authors:  G J Parker; G J Barker; P S Tofts
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

View more
  5 in total

1.  Single-breath-hold abdominal [Formula: see text]  mapping using 3D Cartesian Look-Locker with spatiotemporal sparsity constraints.

Authors:  Felix Lugauer; Jens Wetzl; Christoph Forman; Manuel Schneider; Berthold Kiefer; Joachim Hornegger; Dominik Nickel; Andreas Maier
Journal:  MAGMA       Date:  2018-01-25       Impact factor: 2.310

2.  Rapid volumetric T1 mapping of the abdomen using three-dimensional through-time spiral GRAPPA.

Authors:  Yong Chen; Gregory R Lee; Gunhild Aandal; Chaitra Badve; Katherine L Wright; Mark A Griswold; Nicole Seiberlich; Vikas Gulani
Journal:  Magn Reson Med       Date:  2015-05-18       Impact factor: 4.668

3.  Transverse relaxometry with transmit field-constrained stimulated echo compensation.

Authors:  Reza Basiri; Paolo Federico; Robert Marc Lebel
Journal:  MAGMA       Date:  2019-07-23       Impact factor: 2.310

4.  Automated patient-specific optimization of three-dimensional double-inversion recovery magnetic resonance imaging.

Authors:  Refaat E Gabr; Xiaojun Sun; Amol S Pednekar; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

5.  Quantitative T1, T2, and T2* Mapping and Semi-Quantitative Neuromelanin-Sensitive Magnetic Resonance Imaging of the Human Midbrain.

Authors:  Takashi Hashido; Shigeyoshi Saito
Journal:  PLoS One       Date:  2016-10-21       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.