An improved 3-D Look--Locker imaging method for T(1) parameter estimation.

Ken Nkongchu1, Giles Santyr.   

Abstract

The 3-D Look-Locker (LL) imaging method has been shown to be a highly efficient and accurate method for the volumetric mapping of the spin lattice relaxation time T(1). However, conventional 3-D LL imaging schemes are typically limited to small tip angle RF pulses (<or=5 degrees ) due to the large number of pulses required for adequate phase encoding and sampling of the recovery curve, which would otherwise drive the magnetization to steady state too rapidly, hence, diminishing the signal-to-noise ratio (SNR) available for accurate T(1) estimation. In this work, a more generalized form of the 3-D LL imaging method that incorporates an additional and variable delay time between recovery samples is described, which permits the use of larger tip angles (>5 degrees ), thereby improving the SNR and the accuracy of the method. In phantom studies, a mean T(1) measurement accuracy of less than 2% (0.2-3.1%) using a tip angle of 10 degrees was obtained for a range of T(1) from approximately 300 to 1,700 ms with a measurement time increase of only 15%. This accuracy compares favorably with the conventional 3-D LL method that provided an accuracy between 2.2% and 7.3% using a 5 degrees flip angle.

Mesh:

Substances:

Year:  2005        PMID: 16214611     DOI: 10.1016/j.mri.2005.06.009

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Myocardial T1 mapping with MRI: comparison of look-locker and MOLLI sequences.

Authors:  Marcelo Souto Nacif; Evrim B Turkbey; Neville Gai; Saman Nazarian; Rob J van der Geest; Radwa A Noureldin; Christopher T Sibley; Martin Ugander; Songtao Liu; Andrew E Arai; João A C Lima; David A Bluemke
Journal:  J Magn Reson Imaging       Date:  2011-09-23       Impact factor: 4.813

2.  Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences.

Authors:  Matthias C Schabel; Dennis L Parker
Journal:  Phys Med Biol       Date:  2008-04-17       Impact factor: 3.609

3.  An oxygen-consuming phantom simulating perfused tissue to explore oxygen dynamics and (19)F MRI oximetry.

Authors:  Steven H Ubert Baete; Jan Vandecasteele; Luc Colman; Wilfried De Neve; Yves De Deene
Journal:  MAGMA       Date:  2010-06-25       Impact factor: 2.310

4.  Flip angle mapping with the accelerated 3D look-locker sequence.

Authors:  Trevor Wade; Charles A McKenzie; Brian K Rutt
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

5.  Improved three-dimensional Look-Locker acquisition scheme and angle map filtering procedure for T1 estimation.

Authors:  CheukKai Hui; Emilio Esparza-Coss; Ponnada A Narayana
Journal:  NMR Biomed       Date:  2013-06-20       Impact factor: 4.044

6.  Optimizing the magnetization-prepared rapid gradient-echo (MP-RAGE) sequence.

Authors:  Jinghua Wang; Lili He; Hairong Zheng; Zhong-Lin Lu
Journal:  PLoS One       Date:  2014-05-30       Impact factor: 3.240