Literature DB >> 23768924

A methodology for dosimetry audit of rotational radiotherapy using a commercial detector array.

Mohammad Hussein1, Yatman Tsang, Russell A S Thomas, Clare Gouldstone, David Maughan, Julia A D Snaith, Steven C Bolton, Andrew Nisbet, Catharine H Clark.   

Abstract

PURPOSE: To develop a methodology for the use of a commercial detector array in dosimetry audits of rotational radiotherapy.
MATERIALS AND METHODS: The methodology was developed as part of the development of a national audit of rotational radiotherapy. Ten cancer centres were asked to create a rotational radiotherapy treatment plan for a three-dimensional treatment-planning-system (3DTPS) test and audited. Phantom measurements using a commercial 2D ionisation chamber (IC) array were compared with measurements using 0.125 cm(3) IC, Gafchromic film and alanine pellets in the same plane. Relative and absolute gamma index (γ) comparisons were made for Gafchromic film and 2D-Array planes, respectively.
RESULTS: Comparisons between individual detectors within the 2D-Array against the corresponding IC and alanine measurement showed a statistically significant concordance correlation coefficient (both ρc>0.998, p<0.001) with mean difference of -1.1 ± 1.1% and -0.8 ± 1.1%, respectively, in a high dose PTV. In the γ comparison between the 2D-Array and film it was that the 2D-Array was more likely to fail planes where there was a dose discrepancy due to the absolute analysis performed.
CONCLUSIONS: It has been found that using a commercial detector array for a dosimetry audit of rotational radiotherapy is suitable in place of standard systems of dosimetry.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  2D-Array; Detector arrays; Dosimetry audit; Rotational radiotherapy; Tomotherapy; VMAT

Mesh:

Year:  2013        PMID: 23768924     DOI: 10.1016/j.radonc.2013.05.027

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  14 in total

1.  A national dosimetry audit of intraoperative radiotherapy.

Authors:  D J Eaton; B Earner; P Faulkner; N Dancer
Journal:  Br J Radiol       Date:  2013-10-16       Impact factor: 3.039

2.  Adaptation and validation of a commercial head phantom for cranial radiosurgery dosimetry end-to-end audit.

Authors:  Alexis Dimitriadis; Antony L Palmer; Russell A S Thomas; Andrew Nisbet; Catharine H Clark
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

3.  A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.

Authors:  Christos Moustakis; Fatemeh Ebrahimi Tazehmahalleh; Khaled Elsayad; Francis Fezeu; Sergiu Scobioala
Journal:  Strahlenther Onkol       Date:  2020-01-10       Impact factor: 3.621

4.  The role of complexity metrics in a multi-institutional dosimetry audit of VMAT.

Authors:  Conor K McGarry; Christina E Agnew; Mohammad Hussein; Yatman Tsang; Alan McWilliam; Alan R Hounsell; Catharine H Clark
Journal:  Br J Radiol       Date:  2015-10-29       Impact factor: 3.039

Review 5.  Dosimetric audit in brachytherapy.

Authors:  A L Palmer; D A Bradley; A Nisbet
Journal:  Br J Radiol       Date:  2014-05-06       Impact factor: 3.039

6.  Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.

Authors:  Catharine H Clark; Edwin G A Aird; Steve Bolton; Elizabeth A Miles; Andrew Nisbet; Julia A D Snaith; Russell A S Thomas; Karen Venables; David I Thwaites
Journal:  Br J Radiol       Date:  2015-09-02       Impact factor: 3.039

7.  Dosimetric impact of baseline drift in volumetric modulated arc therapy with breath holding.

Authors:  Shunsuke Ono; Yoshihiro Ueda; Shoki Inui; Masaru Isono; Shingo Ohira; Seiya Murata; Masayoshi Miyazaki; Teruki Teshima
Journal:  Rep Pract Oncol Radiother       Date:  2020-06-08

8.  Inter-departmental dosimetry audits - development of methods and lessons learned.

Authors:  David J Eaton; Steve Bolton; Russell A S Thomas; Catharine H Clark
Journal:  J Med Phys       Date:  2015 Oct-Dec

9.  Verification of high-dose-rate brachytherapy treatment planning dose distribution using liquid-filled ionization chamber array.

Authors:  A B Mohamed Yoosuf; Prakash Jeevanandam; Glenn Whitten; Geraldine Workman; Conor K McGarry
Journal:  J Contemp Brachytherapy       Date:  2018-04-30

Review 10.  Novel methodologies for dosimetry audits: Adapting to advanced radiotherapy techniques.

Authors:  Marlies Pasler; Victor Hernandez; Núria Jornet; Catharine H Clark
Journal:  Phys Imaging Radiat Oncol       Date:  2018-03-19
View more