Predicting the postoperative intraocular lens position using continuous intraoperative optical coherence tomography measurements.

Nino Hirnschall1, Sahand Amir-Asgari, Sophie Maedel, Oliver Findl.   

Abstract

PURPOSE: The aim of this study was to assess, if measuring the position of the lens capsule intraoperatively with a continuous intraoperative optical coherence tomography (OCT) device could be useful to improve the prediction of the intraocular lens (IOL) position.
METHODS: This prospective study included patients who were scheduled for cataract surgery. A prototype operating microscope with an integrated continuous OCT device was used to measure the anterior and posterior lens capsule position at different time points during cataract surgery. In all cases, a capsular tension ring (CTR) was used to tauten the lens capsule. Partial coherence interferometry was used to measure anterior chamber depth (ACD) immediately before, and 1 hour and 3 months postoperatively. Partial least squares regression (PLSR) was used to assess the influence of different pre- and intraoperatively measured parameters.
RESULTS: In total, 70 eyes of 70 patients were included. Mean axial eye length was 23.6 mm (range, 20.6 mm-30.8 mm), mean used IOL power was 22.2 diopters (D; range, 6.0 D-31.5 D). PLSR showed that the anterior lens capsule measured after removing the crystalline lens and after implanting a CTR was a significantly better predictor for the postoperative ACD compared with preoperative ACD measurements.
CONCLUSIONS: The main problem of IOL power calculation, the prediction of the IOL position after surgery, could possibly be reduced by using intraoperative lens capsule measurements instead of preoperative ACD measurements. (ClinicalTrials.gov number, NCT01867541.).

Entities:  

Keywords:  OCT; anterior chamber depth; intraoperative ACD; lens position; refractive error

Mesh:

Year:  2013        PMID: 23761092     DOI: 10.1167/iovs.13-11991

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  18 in total

1.  Automated stereo vision instrument tracking for intraoperative OCT guided anterior segment ophthalmic surgical maneuvers.

Authors:  Mohamed T El-Haddad; Yuankai K Tao
Journal:  Biomed Opt Express       Date:  2015-07-23       Impact factor: 3.732

Review 2.  Intraoperative optical coherence tomography: past, present, and future.

Authors:  J P Ehlers
Journal:  Eye (Lond)       Date:  2015-12-18       Impact factor: 3.775

Review 3.  Clinical utility of intraoperative optical coherence tomography.

Authors:  Mehnaz Khan; Justis P Ehlers
Journal:  Curr Opin Ophthalmol       Date:  2016-05       Impact factor: 3.761

4.  Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers.

Authors:  Yuankai K Tao; Sunil K Srivastava; Justis P Ehlers
Journal:  Biomed Opt Express       Date:  2014-05-20       Impact factor: 3.732

5.  Influence of lens position as detected by an anterior segment analysis system on postoperative refraction in cataract surgery.

Authors:  Jia-Ju Zhang; Jian-Qing Li; Chen Li; Yi-Hong Cao; Pei-Rong Lu
Journal:  Int J Ophthalmol       Date:  2021-07-18       Impact factor: 1.779

6.  [Comparison of two optical biometric devices for intraocular lens calculation].

Authors:  M-S Uckmann; M Stattin; C Zehetner; S Neururer; L Speicher
Journal:  Ophthalmologe       Date:  2019-03       Impact factor: 1.059

7.  Comparison of postoperative refractive outcome in eyes undergoing combined phacovitrectomy vs cataract surgery following vitrectomy.

Authors:  Paris G Tranos; Bruce Allan; Miltiadis Balidis; Athanasios Vakalis; Solon Asteriades; George Anogeianakis; Magda Triantafilla; Nikolaos Kozeis; Panagiotis Stavrakas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-10       Impact factor: 3.117

Review 8.  Intraoperative Anterior Segment Optical Coherence Tomography in the Management of Cataract Surgery: State of the Art.

Authors:  Mario Damiano Toro; Serena Milan; Daniele Tognetto; Robert Rejdak; Ciro Costagliola; Sandrine Anne Zweifel; Chiara Posarelli; Michele Figus; Magdalena Rejdak; Teresio Avitabile; Adriano Carnevali; Rosa Giglio
Journal:  J Clin Med       Date:  2022-07-04       Impact factor: 4.964

9.  Intraoperative OCT-assisted Surgery for Proliferative Diabetic Retinopathy in the DISCOVER Study.

Authors:  Mehnaz Khan; Sunil K Srivastava; Jamie L Reese; Zryan Shwani; Justis P Ehlers
Journal:  Ophthalmol Retina       Date:  2018-05

Review 10.  Clinical applications for intraoperative optical coherence tomography: a systematic review.

Authors:  Marc B Muijzer; Peter A W J Schellekens; Henny J M Beckers; Joke H de Boer; Saskia M Imhof; Robert P L Wisse
Journal:  Eye (Lond)       Date:  2021-07-16       Impact factor: 3.775

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.